Siemens 6AV3971-PA13-0AA0 SIMATIC Panel PC 670
€ 181,00
The Siemens 6AV3971-PA13-0AA0 is a replacement or spare component associated with the SIMATIC Panel PC 670 series, a high-performance industrial panel PC platform developed by Siemens for demanding human-machine interface applications. The 6AV3971-PA13-0AA0 part number falls within the SIMATIC HMI accessory and spare parts range, designed to maintain or restore full functionality of Panel PC 670 systems deployed in industrial environments. This unit is part of Siemens' broader SIMATIC HMI product family, which provides scalable visualization and control solutions for automation systems.
The SIMATIC Panel PC 670 platform on which this component is based features a robust industrial-grade construction with fanless or fan-cooled processor options, integrated display interfaces, and support for standard PC-based software environments including Windows-based operating systems. The system supports communication via standard industrial interfaces such as Ethernet, PROFIBUS, and serial ports, enabling integration with Siemens S7 PLC families and third-party controllers. Internal architecture supports expandable memory configurations and industrial-grade storage media suited for continuous 24/7 operation in harsh environments.
The SIMATIC Panel PC 670 and its associated components are widely used in manufacturing automation, process control, and machine tool industries where a full PC-based HMI platform is required alongside PLC control infrastructure. The platform is suitable for applications demanding high graphical performance, complex SCADA visualization, and data logging capabilities. Industries such as automotive manufacturing, food and beverage processing, and chemical production commonly deploy this system for supervisory control and operator interface tasks.
Technical Specifications
| Series/Product Family | SIMATIC Panel PC 670 |
|---|---|
| Product Type | Spare Part / Accessory for Panel PC |
| Compatible Platform | SIMATIC Panel PC 670 |
| Operating Voltage | 24 V DC |
| Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Communication Interface | Ethernet, PROFIBUS, RS-232 |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Bus System Compatibility | PROFIBUS, Industrial Ethernet |
Common Error Codes & System Events
- Event ID: 100
- Hardware configuration error detected during POST (Power-On Self-Test). Internal component not recognized.
Check seating of all internal modules and expansion cards. Verify compatibility of installed components with the Panel PC 670 platform. - Event ID: 101
- Memory error detected. RAM module fault or incompatible memory installed.
Reseat or replace RAM modules. Ensure memory specifications match those required by the Panel PC 670 platform. - Event ID: 200
- Communication interface fault. PROFIBUS or Ethernet adapter not responding.
Check physical connections and cable integrity. Verify interface card is properly seated. Reload or reinstall interface drivers. - Event ID: 300
- Operating system boot failure. System fails to load the installed OS.
Check integrity of the boot storage device (CompactFlash or hard disk). Restore or reinstall the operating system image using Siemens recovery media. - Event ID: 400
- Watchdog timeout. Application software has stopped responding within the defined watchdog interval.
Restart the application. Check for software deadlocks or resource conflicts. Review application event logs for root cause. - Event ID: 500
- Temperature warning. Internal system temperature has exceeded the defined threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters if present. Verify fan operation on fan-cooled variants. - Event ID: 600
- Storage device error. Read/write failure on internal storage medium.
Replace the CompactFlash card or hard disk drive. Restore system image from backup. Verify storage device compatibility with the platform.
Frequently Asked Questions
What platform is the 6AV3971-PA13-0AA0 compatible with?
The 6AV3971-PA13-0AA0 is a spare part or accessory designed for use with the Siemens SIMATIC Panel PC 670 series of industrial panel computers.
What operating system does the SIMATIC Panel PC 670 support?
The SIMATIC Panel PC 670 supports Windows-based operating systems, including Windows XP Professional and Windows XP Embedded, as configured at the time of manufacture.
What communication interfaces are available on the Panel PC 670 platform?
The Panel PC 670 supports Ethernet (RJ45), PROFIBUS via CP card, and RS-232 serial interfaces, enabling connectivity to Siemens S7 PLCs and other automation devices.
Is the front panel of the Panel PC 670 rated for wash-down environments?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it suitable for environments where dust and water jets may be present, though the rear enclosure requires additional protection measures.
Can WinCC or SIMATIC HMI software run on the Panel PC 670?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SIMATIC HMI visualization software packages, making it suitable for SCADA and supervisory control applications.
Troubleshooting
Panel PC fails to power on after installation of the 6AV3971-PA13-0AA0 component
Verify that the 24 V DC supply voltage is present and within specification at the power input connector. Check for blown internal fuses.
Restore correct supply voltage within the 24 V DC nominal range. Replace any blown fuses with the correct rating as specified in the Panel PC 670 hardware manual.
Display remains blank after power on
Check whether the system completes POST by listening for beep codes or observing status LEDs. Measure backlight supply voltage and inspect display cable connections.
Reseat display interface cables. If the backlight has failed, replace the inverter board or display assembly. If POST fails, diagnose internal component faults using the event log.
System boots but PROFIBUS communication is not established
Verify PROFIBUS cable wiring, termination resistors at both ends of the bus, and correct station address configuration in the CP card settings.
Correct any wiring faults, ensure proper bus termination, and reconfigure the PROFIBUS station address using Siemens STEP 7 or the hardware configuration tool.
Operating system fails to load or enters a boot loop
Attempt to boot from an external medium to determine whether the fault is with the storage device or the OS installation. Check the CompactFlash card or hard disk for errors using diagnostic tools.
Replace the faulty storage medium and restore the operating system image from a Siemens-approved backup or recovery medium. Reconfigure application software as required.
Touchscreen input is unresponsive or inaccurate
Check whether the touchscreen controller is recognized in the operating system device manager. Inspect the touch interface cable for damage or loose connections.
Reseat the touch interface cable. Recalibrate the touchscreen using the Siemens calibration utility within the operating system. If the controller is faulty, replace the touchscreen assembly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page