• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6574-2AC00-2AA1 SIMATIC WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6574-2AC00-2AA1 SIMATIC WinCC flexible 2008

    € 29,00 – € 109,00Price range: € 29,00 through € 109,00

    Reset
    Clear
    SKU: 6AV6574-2AC00-2AA1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens SIMATIC WinCC flexible 2008 (part number 6AV6574-2AC00-2AA1) is an engineering software package belonging to the SIMATIC HMI product family. It serves as the configuration and programming environment for SIMATIC HMI operator panels, enabling engineers to design, configure, and commission human-machine interface applications. This software is part of Siemens' scalable WinCC flexible platform, which bridges panel-based HMI and PC-based SCADA solutions.

    WinCC flexible 2008 provides a comprehensive development environment with tag management, alarm logging, trend displays, recipe management, and multi-language support for up to 32 project languages. The software supports a wide range of SIMATIC HMI hardware targets including Micro Panels, Mobile Panels, Operator Panels (OP), Touch Panels (TP), and Multi Panels (MP). It integrates directly with STEP 7 for symbol import and offers communication drivers for SIMATIC S7-200, S7-300, S7-400, and third-party PLCs via standard protocols such as PROFIBUS DP and MPI. The engineering environment includes a library of pre-built faceplates and graphic objects to accelerate project development.

    WinCC flexible 2008 is used across a broad range of industrial sectors including automotive manufacturing, food and beverage processing, pharmaceutical production, and machine building. It is the standard engineering tool for configuring SIMATIC HMI panels deployed on production lines, packaging machines, press systems, and process plants. The software's tight integration with the SIMATIC automation ecosystem makes it well suited for projects where HMI panels must communicate seamlessly with Siemens S7 PLCs and distributed I/O systems.

    Technical Specifications

    Software Type HMI Engineering Software
    Product Family SIMATIC WinCC flexible 2008
    License Type Single-user license
    Supported HMI Targets Micro Panels, Mobile Panels, OP, TP, MP series
    Supported PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200 (via update)
    Communication Protocols PROFIBUS DP, MPI, PROFINET, Ethernet
    Maximum Project Languages 32
    Operating System Windows XP SP3, Windows Vista, Windows 7
    STEP 7 Integration STEP 7 V5.x symbol import supported
    Alarm Management Bit alarms, analog alarms, alarm logging
    Recipe Management Supported
    Trend Display Supported
    Script Support VB Script for extended functionality
    Media DVD-ROM

    Common Error Codes and Engineering Diagnostics

    Compiler Error: Tag limit exceeded
    The number of configured tags in the project exceeds the license limit for the installed edition.
    Reduce the number of tags in the project or upgrade to a higher WinCC flexible edition with a larger tag count.
    Runtime Transfer Error
    Communication error occurred during project download to the HMI panel.
    Check the PC-to-panel connection (USB, Ethernet, or MPI/PROFIBUS adapter). Verify the correct transfer channel is selected in the Transfer Settings dialog.
    Consistency Check Error: Overlapping addresses
    Two or more tags are configured with overlapping PLC memory addresses.
    Open the tag editor and resolve address conflicts. Use the consistency check function under Project menu to identify all affected tags.
    License Not Found
    No valid WinCC flexible license is detected on the engineering PC.
    Run the Automation License Manager (ALM) to verify license installation. Transfer the license from the original media or a license dongle if required.
    Symbol Import Failed
    STEP 7 symbol table import was unsuccessful due to version mismatch or missing project reference.
    Ensure STEP 7 is installed and the correct project version is referenced. Re-link the STEP 7 project via Project > Connections and retry the symbol import.
    Runtime Version Mismatch
    The WinCC flexible Runtime version on the HMI panel does not match the version used in the engineering project.
    Update the HMI panel Runtime to the matching version using the WinCC flexible installation media before transferring the project.
    Graphics Object Rendering Error
    One or more graphic objects fail to render correctly in the project editor or simulator.
    Check for corrupted graphic files in the project library. Replace affected objects and ensure the PC meets the minimum graphics requirements for the software.

    Frequently Asked Questions

    Which HMI panel families are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports SIMATIC Micro Panels, Mobile Panels, Operator Panels (OP), Touch Panels (TP), and Multi Panels (MP). It does not support the newer Comfort Panel series, which requires WinCC (TIA Portal).

    Is WinCC flexible 2008 compatible with Windows 10?

    WinCC flexible 2008 is not officially supported on Windows 10. It was designed for Windows XP SP3, Windows Vista, and Windows 7. Running it on Windows 10 may cause installation or runtime simulation issues.

    Can WinCC flexible 2008 communicate with SIMATIC S7-1500 PLCs?

    No, WinCC flexible 2008 does not natively support the S7-1500 PLC family. S7-1500 integration requires WinCC in TIA Portal V13 or later.

    Does this software include a runtime license for the HMI panel?

    The engineering software license (6AV6574-2AC00-2AA1) covers the configuration environment only. Runtime licenses for HMI panels are separate and are typically pre-installed on the panel hardware or ordered as separate line items.

    Can projects created in earlier versions of WinCC flexible be opened in WinCC flexible 2008?

    Yes, WinCC flexible 2008 can open and migrate projects created in earlier versions such as WinCC flexible 2005 and 2007. A migration dialog will prompt the user to convert the project to the 2008 format.

    Troubleshooting

    Software installation fails or rolls back on the engineering PC

    Check Windows Event Viewer for installation error codes. Verify that the PC meets minimum hardware requirements and that no conflicting Siemens software versions are installed.

    Uninstall any previous WinCC flexible versions using the Siemens Automation Software Uninstall tool, ensure .NET Framework prerequisites are installed, and re-run the installer with administrator privileges.

    Project cannot be transferred to the HMI panel via Ethernet

    Verify the IP address configured in WinCC flexible Transfer Settings matches the panel's actual IP address. Check network connectivity using a ping command from the engineering PC to the panel.

    Correct the IP address in the Transfer Settings dialog, ensure both devices are on the same subnet, and disable any firewall rules blocking TCP port 102 used by the S7 protocol.

    Simulation of the HMI project fails to start on the engineering PC

    Check whether the WinCC flexible Runtime Simulator is installed as part of the software package. Verify the license status in the Automation License Manager.

    Reinstall the Runtime Simulator component via the WinCC flexible installation media and confirm a valid simulation license is present in the Automation License Manager.

    Imported STEP 7 symbols do not appear in the WinCC flexible tag editor

    Confirm that STEP 7 is installed on the same PC and that the correct STEP 7 project path is linked under Project > Connections in WinCC flexible.

    Re-link the STEP 7 project, compile the STEP 7 symbol table, and use the Update Tags function in WinCC flexible to refresh the imported symbol list.

    Alarm texts appear garbled or in incorrect language on the HMI panel

    Check the language settings in the WinCC flexible project under Project > Languages and Fonts. Verify that the correct runtime language is activated and that fonts supporting the target character set are assigned.

    Assign an appropriate font (such as Arial Unicode MS) to alarm text objects, ensure the target language is enabled and translated in the language editor, and retransfer the project to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart