Siemens 6ES7626-1DG03-0AE3 SIMATIC C7-626
€ 1.589,00
The Siemens SIMATIC C7-626, part number 6ES7626-1DG03-0AE3, is a compact combined controller and operator panel unit belonging to the SIMATIC C7 product family. It integrates a programmable logic controller (PLC) based on the S7-300 CPU architecture with an operator panel (OP) into a single housing, eliminating the need for separate HMI and controller hardware. This all-in-one design is intended for space-constrained control cabinet installations where both control logic and local operator interaction are required.
The C7-626 features a built-in STN monochrome display with touch or key-based input, integrated MPI (Multi-Point Interface) communication for connection to SIMATIC networks, and onboard I/O for direct process interfacing. The unit supports STEP 7 programming software for PLC logic and ProTool or WinCC flexible for HMI configuration. It includes integrated digital inputs and outputs, a real-time clock, and retentive memory backed by a battery or capacitor, ensuring data retention during power loss. The device operates on a 24 V DC supply and conforms to standard industrial environmental ratings.
The SIMATIC C7-626 is well suited for small to medium-sized machine automation tasks in industries such as packaging, material handling, food and beverage, and general manufacturing. Its compact integrated design makes it particularly appropriate for OEM machine builders seeking to reduce panel space and wiring complexity. The combination of local visualization and control logic in one unit simplifies commissioning and reduces overall system cost for standalone machine applications.
Technical Specifications
| Input Voltage | 24 V DC |
|---|---|
| Display Type | STN monochrome LCD |
| Communication Interface | MPI (Multi-Point Interface) |
| Integrated I/O | Digital inputs and outputs onboard |
| Programming Software | STEP 7 (PLC), ProTool / WinCC flexible (HMI) |
| Real-Time Clock | Integrated |
| Operating Temperature | 0 °C to +55 °C |
| Storage Temperature | -20 °C to +70 °C |
| Relative Humidity | 10 % to 95 % (non-condensing) |
| IP Rating (Front) | IP65 |
| Mounting | Panel mounting |
| Series | SIMATIC C7 |
| Certifications | CE, UL |
| Memory Backup | Battery or capacitor-backed retentive memory |
Common Error Codes & System Events
- Event ID: 10000
- Loss of communication on MPI interface
Check MPI cable connections and termination resistors. Verify MPI address settings and network configuration in STEP 7. - Event ID: 10001
- Battery low or battery failure — retentive data at risk
Replace the backup battery as soon as possible to prevent loss of retentive memory and real-time clock data. - Event ID: 10002
- CPU in STOP mode — program execution halted
Check the diagnostic buffer in STEP 7 for the cause of the STOP. Correct any programming errors or hardware faults and perform a warm restart. - Event ID: 10003
- I/O access error — configured I/O module not responding
Verify wiring and connections to the I/O module. Check module status LEDs and replace faulty module if necessary. - Event ID: 10004
- Configuration mismatch — actual hardware does not match STEP 7 configuration
Compare the hardware configuration in STEP 7 with the physically installed modules. Update the configuration and download to the CPU. - Event ID: 10005
- Watchdog timeout — CPU detected a program cycle time overrun
Review the PLC program for loops or excessive processing. Increase the watchdog time in the CPU properties if justified, or optimize the program cycle. - Event ID: 10006
- HMI project transfer error — communication failure during project download
Check the MPI or PC adapter connection. Ensure the correct COM port and transfer settings are selected in ProTool or WinCC flexible.
Frequently Asked Questions
What programming software is required for the SIMATIC C7-626?
The PLC portion is programmed using Siemens STEP 7, while the HMI screens are configured using ProTool or WinCC flexible. Both software packages must be used together to fully commission the unit.
What communication interfaces does the C7-626 support?
The C7-626 includes an integrated MPI (Multi-Point Interface) port, which allows connection to SIMATIC S7 networks, programming devices (PG/PC), and other SIMATIC HMI or PLC devices.
Can the C7-626 be used as a standalone controller without an external PLC?
Yes, the C7-626 integrates a full S7-300-based CPU with onboard I/O, allowing it to operate as a standalone controller with local operator interface without requiring a separate PLC.
What is the supply voltage for the 6ES7626-1DG03-0AE3?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC C7 family devices.
Is the C7-626 compatible with PROFIBUS?
The base C7-626 unit communicates via MPI. PROFIBUS-DP connectivity may require an additional communications module or a variant of the C7 family that includes an integrated PROFIBUS interface.
Troubleshooting
Display remains blank after power on
Measure 24 V DC at the power supply terminals. Check internal fuse and inspect the power supply connector for secure seating.
Restore correct supply voltage if absent. Replace any blown fuse with the correct rating. If voltage is present and fuse is intact, the internal power supply or display unit may require replacement.
CPU remains in STOP mode and will not transition to RUN
Connect a programming device via MPI and open the diagnostic buffer in STEP 7 to identify the specific fault causing the STOP condition.
Resolve the identified fault — this may involve correcting a program error, replacing a faulty I/O module, or performing a memory reset (MRES) followed by a fresh program download.
MPI communication cannot be established with a programming device
Verify the MPI cable is correctly connected and that the PC adapter is functioning. Check that the MPI address of the C7 unit matches the address configured in STEP 7.
Correct any address conflicts, replace faulty MPI cable or PC adapter, and ensure termination resistors are properly placed at both ends of the MPI segment.
HMI screens freeze or do not update during operation
Check the MPI connection between the HMI and PLC portions of the C7 unit. Review the HMI project for tag polling errors or communication timeouts in the WinCC flexible or ProTool diagnostics.
Reload the HMI project to the device. If the issue persists, perform a complete power cycle. Check for firmware compatibility between the HMI project version and the device firmware.
Retentive data lost after power cycle
Check the backup battery status indicator and measure battery voltage. Inspect whether the battery holder contacts are clean and making good contact.
Replace the backup battery with the correct Siemens-specified replacement. After replacement, re-initialize retentive data areas and verify real-time clock settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page