Siemens 6AV6545-0BB15-2AX0 TP270
€ 524,00 – € 650,00Price range: € 524,00 through € 650,00
The Siemens 6AV6545-0BB15-2AX0 is a Touch Panel 270 (TP270) belonging to the SIMATIC HMI family, designed for machine-level visualization and operator control in industrial automation environments. This unit features a 10.4-inch TFT color display and operates as a standalone HMI panel, communicating directly with Siemens PLCs and third-party controllers. It is configured and programmed using Siemens ProTool or WinCC flexible engineering software.
The TP270 panel is equipped with a resistive touchscreen interface and supports MPI, PROFIBUS DP, and serial communication interfaces for flexible integration into existing automation networks. It runs on Windows CE and provides sufficient onboard memory for storing project data, recipes, and alarm logs. The unit operates on a 24 V DC supply and is built to withstand the demands of industrial environments, with a front panel protection rating of IP65.
The TP270 10-inch variant is widely deployed in manufacturing, automotive, food and beverage, and process industries for machine operator interfaces, production line control panels, and process monitoring stations. Its compatibility with the SIMATIC S7 PLC family and support for structured alarm management and recipe handling make it suitable for applications requiring reliable and straightforward HMI functionality at the machine level.
Technical Specifications
| Display Size | 10.4 inch |
|---|---|
| Display Type | TFT Color LCD |
| Display Colors | 256 colors |
| Display Resolution | 640 x 480 pixels (VGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 25 W |
| Communication Interface | MPI, PROFIBUS DP, RS-232, RS-422/485 |
| Operating System | Windows CE |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| Mounting | Panel mounting |
| Certifications | CE, UL, cUL |
Common Error Codes & System Events
- Event ID: 10000
- Connection to PLC could not be established or was interrupted during runtime.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. - Event ID: 10001
- Communication timeout to the configured PLC controller.
Verify the communication cable integrity, check baud rate settings, and confirm the PLC is in RUN mode. - Event ID: 20000
- Project download failed or project data is corrupted.
Re-download the project from WinCC flexible or ProTool. Check available memory on the panel and ensure the engineering software version is compatible. - Event ID: 40000
- Tag read/write error — the HMI cannot access a configured PLC tag.
Verify the tag address in the project configuration matches the actual PLC data block or memory area. Check PLC program for address conflicts. - Event ID: 50000
- Recipe data error — recipe record could not be read or written.
Check available storage memory. Re-transfer recipe data from the engineering PC or clear corrupted recipe records via the panel's recipe view. - Event ID: 70000
- System memory low — available RAM or flash memory is critically low.
Delete unused project data, alarm logs, or recipe records. Consider reducing project size or archiving historical data to an external storage device. - Event ID: 80000
- Touchscreen calibration error or touch input not responding correctly.
Perform a touchscreen recalibration via the Control Panel in Windows CE. If the issue persists, inspect the touchscreen overlay for damage and consider replacement.
Frequently Asked Questions
What engineering software is used to program the TP270 6AV6545-0BB15-2AX0?
The TP270 is programmed using Siemens ProTool 6.0 or WinCC flexible 2004 and later versions. The project is transferred to the panel via MPI cable or serial connection.
Which Siemens PLCs are compatible with this HMI panel?
The TP270 is compatible with the SIMATIC S7-200, S7-300, and S7-400 PLC families via MPI or PROFIBUS DP. It also supports communication with S5 controllers and third-party devices via serial interfaces.
What is the supply voltage for the 6AV6545-0BB15-2AX0?
The panel requires a 24 V DC power supply. It is recommended to use a regulated SELV power supply with adequate current capacity, typically at least 2 A.
Does the TP270 support recipe management and alarm logging?
Yes, the TP270 supports recipe management, alarm logging, and trend displays as standard functions within WinCC flexible or ProTool projects. Data can be stored in the panel's internal flash memory.
What is the front panel protection rating of the TP270?
The front panel of the TP270 carries an IP65 protection rating, making it suitable for installation in control cabinet doors where it may be exposed to dust and water spray.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check that the voltage is within the specified tolerance range. Inspect the internal fuse if accessible.
Ensure the power supply provides a stable 24 V DC output. Replace the power supply if voltage is out of range. If voltage is correct but display remains blank, the backlight inverter or internal power board may require replacement.
Touchscreen does not respond or responds inaccurately
Attempt to interact with the touchscreen in the Windows CE Control Panel environment. Determine whether the issue is present in the OS layer or only within the HMI runtime application.
Perform a touchscreen recalibration via Start > Settings > Control Panel > Stylus in Windows CE. If calibration does not resolve the issue, the resistive touch overlay may be damaged and should be replaced.
HMI cannot connect to the PLC via MPI or PROFIBUS
Check the MPI or PROFIBUS cable for continuity and correct pin assignment. Verify bus termination is applied at both ends of the network. Confirm the PLC node address and baud rate match the HMI project settings.
Replace the communication cable if faulty. Correct address and baud rate settings in the HMI project and re-download. Ensure only one active bus master is present if using MPI.
Panel repeatedly reboots or freezes during operation
Check the supply voltage for ripple or voltage drops under load. Review the alarm log and system event buffer in WinCC flexible for recurring event IDs that may indicate a software or memory fault.
Stabilize the power supply and ensure adequate current capacity. If the issue is software-related, perform a factory reset of the panel and re-download the project. Update the panel firmware if an older version is installed.
Project download fails from engineering PC
Verify the communication cable between the PC and the panel is correctly connected and the correct COM port or MPI adapter is selected in the transfer settings. Check that the panel is in Transfer mode.
Set the panel to Transfer mode via the Start Center or loader menu. Ensure the correct transfer channel is configured in WinCC flexible. Try a different MPI/PC adapter or cable if the issue persists.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page