Siemens 6AV7613-0AB10-0BH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AB10-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7613-0AB10-0BH0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive screen for operator interaction. It is powered by an Intel Celeron processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB ports, serial COM ports, and an Ethernet interface for network connectivity and integration with Siemens S7 PLC systems. It is designed for front-panel mounting with an IP65 protection rating on the front face, making it suitable for use in control cabinet doors.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, food and beverage, chemical, and process industries where a full PC-based HMI platform is required. Its compatibility with standard Windows software and Siemens automation ecosystems makes it suitable for complex visualization tasks, data logging, and recipe management. The panel PC format allows direct integration into machine control panels and operator stations without requiring a separate PC enclosure.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Mounting | Front panel mounting |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM ports) |
| Operating System | Windows XP / Windows 2000 |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
Check the CompactFlash card or hard disk for errors. Reinstall or restore the operating system image using the Siemens recovery tools. - Event ID: 1000
- Application crash — the HMI runtime software (e.g. WinCC flexible Runtime) has terminated unexpectedly.
Review the Windows Event Viewer for application error details. Reinstall the HMI runtime software and ensure the correct version is installed for this hardware. - Communication Error
- Loss of communication between the Panel PC and the connected PLC (e.g. S7-300/400) via Ethernet or MPI/PROFIBUS adapter.
Verify network cable connections and IP address configuration. Check the communication driver settings in the HMI project and confirm the PLC is in RUN mode. - Watchdog Timeout
- The system watchdog has detected that the operating system or application has stopped responding within the defined time window.
Perform a controlled restart of the Panel PC. If the fault recurs, check for resource overload (CPU, memory) and review running background processes. - Touch Calibration Error
- The touchscreen is not responding accurately to input or has lost calibration data.
Run the touchscreen calibration utility from the Windows Control Panel or the Siemens calibration tool. If calibration cannot be saved, check the CompactFlash card for write errors. - Temperature Warning
- The internal temperature sensor has detected that the operating temperature is approaching or exceeding the specified limit.
Check that ventilation slots are not blocked. Verify ambient temperature is within the 0 °C to +45 °C operating range. Clean any dust from internal fans or heat sinks if accessible. - Storage Medium Error
- The CompactFlash card or hard disk drive has reported a read/write error or is not detected by the system.
Replace the CompactFlash card or HDD with a compatible unit. Restore the operating system and HMI project from a backup image.
Frequently Asked Questions
What operating systems are supported by the 6AV7613-0AB10-0BH0?
The SIMATIC Panel PC 670 (6AV7613-0AB10-0BH0) supports Windows XP Professional and Windows 2000, which are pre-installed depending on the variant ordered. It is compatible with SIMATIC WinCC and WinCC flexible HMI software.
What is the display size and resolution of this Panel PC?
This unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen for operator input.
What is the front panel protection rating of the 6AV7613-0AB10-0BH0?
The front face of the Panel PC carries an IP65 protection rating, making it resistant to dust and water jets, suitable for installation in control cabinet doors.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial COM ports as standard interfaces. Additional communication to Siemens PLCs can be achieved via Ethernet using standard S7 communication protocols.
Is this Panel PC compatible with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with SIMATIC WinCC and WinCC flexible runtime software, making it suitable for use as a visualization station in Siemens automation systems.
Troubleshooting
Panel PC does not boot and display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the CompactFlash card or hard disk is properly seated and detected in the BIOS.
Reseat the CompactFlash card or HDD. If the storage medium is faulty, replace it and restore the operating system image from a Siemens backup. If the display remains blank, test the backlight inverter and display cable connections.
Touchscreen does not respond or responds inaccurately
Determine whether the issue is a complete loss of touch input or a calibration drift. Check the touch controller driver status in Windows Device Manager.
Run the touchscreen calibration utility from the Windows Control Panel. If the touch controller is not recognized, reinstall the touch driver. If the touchscreen hardware is damaged, the display assembly may require replacement.
Loss of communication with connected Siemens PLC
Check the Ethernet cable connection and verify the IP address settings on both the Panel PC and the PLC. Confirm the HMI project communication settings match the PLC configuration.
Correct any IP address conflicts or misconfiguration in the HMI project. Replace the Ethernet cable if faulty. Ensure the correct S7 communication driver is installed and active on the Panel PC.
HMI runtime software crashes repeatedly or fails to start
Review the Windows Event Viewer application log for error codes and crash details. Check available disk space on the storage medium and verify the runtime software version compatibility.
Reinstall the WinCC or WinCC flexible runtime software. Ensure the software version is compatible with the installed Windows version and the Panel PC hardware. Free up disk space if the storage medium is near capacity.
Panel PC overheating or shutting down unexpectedly
Check the ambient temperature around the installation. Inspect ventilation slots for blockages and verify that the cooling fan (if fitted) is operating correctly.
Ensure the installation environment is within the 0 °C to +45 °C operating range. Clear any obstructions from ventilation slots and clean dust from the unit. If the internal fan has failed, arrange for replacement of the cooling assembly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page