• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AA30-0BG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AA30-0BG0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AA30-0BG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AA30-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC platform, enabling both operator control and data processing within a single integrated device.

    The SIMATIC Panel PC 670 (6AV7613-0AA30-0BG0) features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and a touch-sensitive screen for intuitive operator interaction. The unit is built around an industrial-grade PC architecture supporting Windows-based operating systems, and is equipped with standard PC interfaces including USB, serial (COM), and Ethernet ports for connectivity to controllers and peripheral devices. It is designed for front-panel mounting with an IP65 protection rating on the front face, making it suitable for use in environments where dust and water ingress are a concern. The device supports standard PC expansion and is compatible with Siemens SIMATIC WinCC and other SCADA/HMI software packages.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, integrated PC-based HMI solution is required. Its panel-mount design makes it suitable for integration into control cabinets and operator stations on production lines, packaging machinery, and process plants. The combination of a full PC platform with an industrial-hardened enclosure makes it appropriate for applications requiring complex visualization, data logging, and recipe management alongside real-time process control.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front), IP20 (rear)
    Mounting Panel mounting (front flush mount)
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM ports)
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Windows XP Professional / Windows 2000

    Common Error Codes & System Events

    Event ID: 1001
    System boot failure or operating system not found during startup sequence.
    Check hard disk or Compact Flash card for correct installation and integrity. Verify BIOS boot sequence settings and replace storage media if corrupted.
    Event ID: 1003
    Application error causing an unexpected system exception or crash.
    Review Windows Event Viewer logs for the faulting application. Reinstall the affected software or update drivers. Check RAM modules for faults.
    Event ID: 7026
    A boot-start or system-start driver failed to load during Windows initialization.
    Boot into safe mode and check Device Manager for driver conflicts. Reinstall or update the relevant hardware driver.
    Event ID: 6008
    The previous system shutdown was unexpected, indicating a possible power loss or system crash.
    Check the 24 V DC supply for stability and correct voltage level. Inspect UPS or power conditioning equipment. Review system logs for preceding errors.
    Hardware Watchdog Timeout
    The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
    Investigate the cause of the OS hang. Check for software deadlocks, insufficient RAM, or overheating. Ensure adequate ventilation around the unit.
    Fan Failure Warning
    The internal cooling fan has stopped or is operating below the minimum required speed.
    Replace the internal fan with a compatible spare. Ensure ventilation slots are not blocked. Check ambient temperature is within specification.
    Battery Low Warning
    The CMOS/RTC backup battery voltage is below the minimum threshold, risking loss of BIOS settings and real-time clock data.
    Replace the internal CMOS battery (typically CR2032 or equivalent). After replacement, reconfigure BIOS settings and synchronize the system clock.
    Temperature Warning
    Internal system temperature has exceeded the defined threshold, triggering a thermal warning.
    Check ambient temperature and ensure it is within the 0-45 °C operating range. Clean air filters and ventilation openings. Verify cooling fan operation.

    Frequently Asked Questions

    What is the display size and resolution of the 6AV7613-0AA30-0BG0?

    This unit features a 15-inch TFT color LCD with a resolution of 1024 x 768 pixels (XGA) and a resistive touchscreen interface.

    What operating system does the SIMATIC Panel PC 670 (6AV7613-0AA30-0BG0) support?

    The Panel PC 670 supports Windows XP Professional and Windows 2000, making it compatible with Siemens WinCC and other Windows-based SCADA and HMI software.

    What is the supply voltage for this Panel PC?

    The 6AV7613-0AA30-0BG0 operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC devices intended for industrial cabinet installation.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7613-0AA30-0BG0 carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and other PC-based HMI and SCADA software packages that run on Windows XP or Windows 2000.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector. Verify the internal fuse is intact. Confirm the display backlight is functioning by shining a light at the screen to check for a faint image.

    If supply voltage is correct and the backlight is failed, replace the CCFL backlight or the inverter board. If no power is reaching the unit, inspect the power connector and wiring. Replace the internal power supply board if faulty.

    Touchscreen input is inaccurate or unresponsive

    Check whether the touchscreen calibration has been performed. Inspect the touchscreen surface for damage, contamination, or moisture. Verify the touchscreen controller driver is correctly installed in Device Manager.

    Recalibrate the touchscreen using the Windows touchscreen calibration utility. Clean the screen surface with a dry cloth. If the touchscreen remains unresponsive, replace the resistive touch panel overlay.

    System fails to boot or displays a 'missing operating system' error

    Check the Compact Flash card or hard disk drive for correct seating and physical condition. Enter BIOS setup to verify the boot device order and that the storage device is detected.

    Reseat or replace the Compact Flash card or HDD. Restore the operating system image from a backup. If the storage device is not detected in BIOS, replace it with a compatible unit.

    Unit reboots unexpectedly or hardware watchdog triggers repeatedly

    Monitor the 24 V DC supply for voltage drops or instability under load. Check internal temperatures using system monitoring software. Review Windows Event Viewer for application or driver errors preceding the reboot.

    Stabilize the power supply and ensure it is rated for the Panel PC's power consumption. Improve cabinet ventilation if thermal issues are detected. Identify and resolve the software or driver fault causing the OS to become unresponsive.

    Ethernet communication is not established with the PLC or network

    Check the Ethernet cable and RJ45 connector for physical damage. Verify the IP address configuration in Windows Network Settings. Confirm the network switch or PLC port is active.

    Replace the Ethernet cable if damaged. Reconfigure the IP address to match the required network subnet. If the onboard NIC is faulty, install a compatible PC Card or PCI Ethernet adapter as a replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart