Siemens 6AV7613-0AA22-0CF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA22-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7613-0AA22-0CF0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an industrial-grade processor platform running Microsoft Windows, with onboard RAM and CompactFlash or hard disk storage options. The unit provides standard PC interfaces including USB, serial (RS-232), parallel, and Ethernet ports, enabling integration with a wide range of automation and IT systems. The enclosure is rated to IP65 at the front panel, protecting against dust and water ingress in industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, food and beverage, and process industries where a robust, panel-integrated PC is required for SCADA, HMI visualization, and data acquisition tasks. Its compatibility with Siemens WinCC and other SCADA software packages makes it suitable for integration into SIMATIC automation architectures. The fanless or low-maintenance design options make it appropriate for environments where reliability and reduced maintenance intervals are critical.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Type | TFT Color LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive Touch Screen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232, Parallel |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Microsoft Windows |
Common Error Codes & System Events
- Event ID: 1000
- Application error — a software application has crashed or terminated unexpectedly on the Panel PC.
Check the Windows Event Viewer for details. Restart the affected application. If recurring, reinstall the application or check for software conflicts. - Event ID: 7026
- A boot-start or system-start driver failed to load during Windows startup.
Check Device Manager for driver errors. Reinstall or update the relevant driver. Verify hardware connections and compatibility. - Event ID: 6008
- The system was shut down unexpectedly (dirty shutdown), indicating a power loss or system crash.
Check the 24 V DC power supply for stability. Review application logs for crash causes. Ensure UPS or stable power source is in use. - BIOS POST Error
- The Panel PC fails to complete the Power-On Self-Test, indicating a hardware fault such as missing RAM or storage device.
Reseat RAM modules and storage media (CompactFlash or HDD). Check all internal connections. Replace faulty hardware components as needed. - WinCC Runtime Error
- Siemens WinCC visualization software reports a runtime fault, often due to configuration mismatch or communication failure with a PLC.
Verify PLC communication settings and network connectivity. Check WinCC project configuration. Restart WinCC runtime and review diagnostic logs. - No Boot Device Found
- The Panel PC cannot locate a bootable operating system on the configured storage device.
Check that the CompactFlash card or hard disk is properly seated and recognized in BIOS. Replace the storage device if faulty and restore the OS image. - Touchscreen Not Responding
- The resistive touch screen does not register input, which may be caused by driver failure, calibration loss, or hardware fault.
Recalibrate the touch screen via the Windows control panel. Reinstall touch screen drivers. If hardware fault is suspected, inspect the touch controller connection or replace the touch overlay.
Frequently Asked Questions
What is the supply voltage for the 6AV7613-0AA22-0CF0?
The SIMATIC Panel PC 670 (6AV7613-0AA22-0CF0) operates on a 24 V DC power supply, which is standard for Siemens industrial panel PCs.
What display size and resolution does this Panel PC have?
This unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen interface.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other Windows-based SCADA and HMI software packages, making it fully compatible with SIMATIC automation environments.
What is the front panel protection rating of this unit?
The front panel of the 6AV7613-0AA22-0CF0 is rated to IP65, providing protection against dust and low-pressure water jets, suitable for industrial panel installation.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB, RS-232 serial, and parallel interfaces, enabling connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector to confirm correct voltage level. Check internal fuses and inspect the power supply board for visible damage.
Replace any blown internal fuses with the correct rating. If the power supply board is faulty, replace it. Ensure the 24 V DC source is stable and within the specified voltage tolerance.
Display is blank but the PC appears to be running (HDD activity, fans operating)
Check the display cable connection between the mainboard and the TFT panel. Test the backlight inverter by listening for a faint high-frequency sound or measuring inverter output voltage.
Reseat or replace the internal display cable. Replace the backlight inverter or the TFT display panel if the backlight has failed. Adjust display brightness settings in Windows if software-related.
Touch screen input is inaccurate or unresponsive
Attempt touch screen recalibration via the Windows Control Panel. Check Device Manager for touch controller driver errors or conflicts.
Recalibrate the resistive touch screen using the manufacturer calibration utility. Reinstall touch screen drivers if errors are present. If the touch overlay is physically damaged, replace it.
Windows fails to boot and displays a blue screen (BSOD)
Note the STOP error code displayed on the blue screen. Boot from an external device to run disk diagnostics on the CompactFlash or HDD storage.
Replace faulty storage media and restore the Windows OS image from a backup. If RAM is identified as the cause, reseat or replace the RAM module. Update or roll back drivers as indicated by the STOP code.
Ethernet communication is not established with the PLC or network
Check the Ethernet cable and RJ45 connector for physical damage. Verify IP address configuration in Windows Network Settings and confirm the network switch or PLC port is active.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network subnet. If the onboard NIC is faulty, install a compatible USB-to-Ethernet adapter or replace the mainboard.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page