Siemens 6AV7613-0AA22-0CE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA22-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for use as a human-machine interface (HMI) in demanding automation environments. This unit combines a flat-panel display with an integrated PC platform, providing both visualization and computing capabilities in a single device.
The SIMATIC Panel PC 670 6AV7613-0AA22-0CE0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, supporting SIMATIC WinCC and other HMI software packages. The unit provides standard PC interfaces including USB, serial (COM), and Ethernet ports, and supports integration into PROFIBUS and Industrial Ethernet networks. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, chemical, and machine-building industries where a robust, panel-integrated PC solution is required. It is suitable for applications demanding complex visualization, data logging, and process control on the shop floor. Its fanless or low-maintenance design options and industrial-grade construction make it appropriate for continuous operation in harsh production environments.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 64,000 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly, possibly due to a corrupted system partition or failed storage medium.
Check the CompactFlash card or hard disk for errors. Restore the system image using the Siemens recovery tool or replace the storage medium. - Event ID: 1000
- Application crash — a WinCC or HMI runtime application has terminated unexpectedly.
Review the Windows Event Viewer for application error details. Reinstall or repair the WinCC runtime software and check for software conflicts. - Event ID: 7000
- Service failed to start — a required Windows service did not start during boot, which may affect HMI communication or runtime operation.
Check the Windows Event Log for the specific service name. Restart the service manually or reconfigure service startup settings. - Communication Error
- Loss of communication between the Panel PC and the PLC or field devices, typically via PROFIBUS or Industrial Ethernet.
Verify network cable connections and IP address configuration. Check PROFIBUS DP address settings and ensure the network interface driver is correctly installed. - Watchdog Timeout
- The system watchdog has detected that the operating system or application has stopped responding within the defined time window.
Restart the Panel PC. Investigate CPU load and running processes. If recurring, check for hardware faults or software loops in the HMI application. - Temperature Warning
- Internal temperature of the Panel PC has exceeded the warning threshold, risking hardware damage or system shutdown.
Check that ventilation slots are unobstructed. Verify ambient temperature is within specification (0–45 °C). Clean any dust from cooling paths and check fan operation if applicable. - Storage Medium Error
- Read/write error detected on the CompactFlash card or hard disk drive used for the operating system or data storage.
Back up data immediately if possible. Run a disk check utility. Replace the CompactFlash card or HDD and restore the system image from a backup.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 6AV7613-0AA22-0CE0 run?
This Panel PC is designed to run Windows XP Professional or Windows 2000 Professional, and is compatible with SIMATIC WinCC and other Siemens HMI software packages.
What is the display size and resolution of this unit?
The 6AV7613-0AA22-0CE0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors.
What is the front panel protection rating?
The front panel of the SIMATIC Panel PC 670 meets IP65 protection, making it resistant to dust and water jets, suitable for industrial environments.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial (COM) interfaces, supporting integration into Industrial Ethernet and PROFIBUS networks via appropriate software and hardware.
Can this Panel PC be used with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with SIMATIC WinCC visualization software, making it suitable for SCADA and HMI applications within Siemens automation environments.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the supply is within tolerance and the power LED status. Measure voltage at the internal power supply output.
Ensure the 24 V DC supply is stable and correctly connected. If the internal power supply has failed, it may need replacement. Also check the display backlight inverter, as a failed backlight can cause a blank screen while the system is otherwise operational.
Panel PC fails to boot or gets stuck at startup screen
Check the CompactFlash card or hard disk drive for errors. Attempt to boot from an external medium to determine if the storage device is faulty.
Replace or reformat the CompactFlash card and restore the factory system image using the Siemens recovery partition or a backup image. Ensure the BIOS boot order is correctly configured.
Touchscreen does not respond or is inaccurate
Check if the touchscreen controller is recognized in Device Manager. Determine whether the issue is a calibration problem or a hardware fault by testing with a mouse.
Recalibrate the touchscreen using the calibration utility in the Windows Control Panel. If calibration does not resolve the issue, check the touchscreen ribbon cable connection or replace the touchscreen overlay.
Loss of communication with PLC or network devices
Verify the Ethernet cable and network switch connections. Check the IP address configuration in Windows Network Settings and confirm the PLC is reachable via ping.
Reconfigure the IP address if there is a conflict. Replace the Ethernet cable if damaged. Reinstall the network interface driver if the adapter is not recognized. Check firewall settings that may be blocking communication.
System runs slowly or HMI application freezes
Monitor CPU and memory usage via Windows Task Manager. Check for background processes consuming excessive resources or for a nearly full storage medium.
Close unnecessary background applications and disable non-essential startup programs. If the storage medium is nearly full, archive or delete old data logs. Consider increasing virtual memory settings or upgrading RAM if the hardware configuration permits.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page