Siemens 6AV7613-0AA22-0BH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA22-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in flat-panel display with a full PC architecture, enabling it to run standard PC operating systems and SCADA/HMI software.
The SIMATIC Panel PC 670 6AV7613-0AA22-0BH0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on a 24 V DC supply voltage. The unit provides standard PC interfaces including USB, serial (COM), parallel, and Ethernet ports, and is designed for front-panel mounting with an IP65-rated front bezel for protection against dust and water ingress. An integrated CompactFlash slot and hard disk drive option provide flexible storage configurations.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, fanless or low-maintenance industrial PC with an integrated display is required. Its compatibility with standard Windows operating systems and Siemens WinCC/STEP 7 software makes it suitable for integration into existing Siemens automation architectures. Typical applications include production line visualization, process monitoring, and machine control panels in automotive, food and beverage, and chemical processing plants.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Processor | Intel Celeron |
| Operating System | Windows XP / Windows 2000 (compatible) |
| Storage | CompactFlash slot; optional hard disk drive |
| Communication Interfaces | Ethernet (RJ45), USB, RS-232 (COM), Parallel port |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Mounting | Front panel mounting |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST
Check hard disk or CompactFlash card integrity. Reseat storage media and verify BIOS boot sequence settings. - Event ID: 101
- Hardware watchdog timeout — the system did not respond within the watchdog interval
Check CPU load and running processes. Reconfigure or disable the watchdog timer in BIOS if not required, or optimize application performance. - Event ID: 200
- Fan failure detected (if fan-equipped variant)
Inspect and clean the cooling fan. Replace the fan module if it is not spinning or is running below rated speed. - Event ID: 300
- Battery low warning — CMOS/RTC backup battery voltage is low
Replace the internal CMOS battery (typically CR2032) to prevent loss of BIOS settings and real-time clock data. - Event ID: 400
- Touchscreen calibration error — touch input is misaligned or unresponsive
Run the touchscreen calibration utility from the Windows control panel or Siemens touchscreen driver software. Clean the touch surface and check ribbon cable connections. - Event ID: 500
- Ethernet communication failure — network interface not detected or link lost
Check Ethernet cable and switch connection. Verify network adapter settings in Device Manager. Reinstall network drivers if the adapter is not recognized. - Event ID: 600
- Storage device not found — CompactFlash or HDD not detected at boot
Reseat the CompactFlash card or hard disk drive. Check IDE/CF interface connector. Replace storage media if the device remains undetected.
Frequently Asked Questions
What is the supply voltage for the 6AV7613-0AA22-0BH0?
This Panel PC operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC 670 units.
What display size and resolution does this unit have?
The 6AV7613-0AA22-0BH0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
Is this Panel PC compatible with Siemens WinCC software?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and other standard PC-based HMI software, as it runs a standard Windows operating system.
What is the front panel protection rating of this unit?
The front panel of the 6AV7613-0AA22-0BH0 carries an IP65 protection rating, making it resistant to dust and water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, RS-232 serial (COM) ports, and a parallel port for peripheral and network connectivity.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify that the supply is within tolerance and that the power LED is illuminated. Inspect internal fuses if accessible.
Restore correct 24 V DC supply. If the supply is correct but the display remains blank, the backlight inverter or the LCD panel may have failed and should be replaced.
Touchscreen does not respond or registers incorrect touch positions
Check whether the touch driver is loaded correctly in Device Manager. Inspect the touchscreen ribbon cable connection inside the unit for damage or looseness.
Recalibrate the touchscreen using the Siemens calibration utility or Windows Pointer Device settings. If calibration fails, replace the touchscreen overlay or ribbon cable.
Panel PC fails to boot or hangs at POST screen
Check the CompactFlash card or hard disk drive for errors using a bootable diagnostic tool. Verify BIOS settings are correct and that the boot device is detected.
Reseat or replace the storage media. Restore BIOS defaults if settings have been corrupted. Reinstall the operating system if the storage device is functional but the OS partition is damaged.
Ethernet connection is not established
Verify the Ethernet cable and switch port are functional. Check Device Manager for network adapter errors or missing drivers. Confirm IP address configuration is correct.
Reinstall or update the network adapter driver. Replace the Ethernet cable. If the onboard NIC is faulty, use a USB-to-Ethernet adapter as a temporary workaround and arrange for board-level repair.
BIOS date and time reset after each power cycle
This indicates the internal CMOS backup battery has discharged. Confirm by checking the BIOS clock after a power cycle.
Replace the internal CMOS battery (typically a CR2032 coin cell). After replacement, re-enter BIOS settings and set the correct date, time, and boot configuration.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page