Siemens 6AV7613-0AA20-0CG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA20-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7613-0AA20-0CG0) features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports 65,536 colors. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, providing compatibility with standard SCADA and HMI software packages including WinCC and WinCC flexible. The unit includes multiple communication interfaces such as Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed for panel mounting with an IP65-rated front face for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, food and beverage, and chemical processing industries. It is suited for applications requiring a full PC-based HMI platform with the ability to run complex visualization software, data logging, and process control tasks. Its rugged industrial design and broad software compatibility make it appropriate for integration into control cabinets and operator stations on the factory floor.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Colors | 65,536 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM ports) |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Microsoft Windows XP Professional |
Common Error Codes and System Events
- Event ID: 100
- System startup failure or BIOS POST error detected during boot sequence.
Check hardware connections, reseat RAM and expansion cards. Verify BIOS settings and restore defaults if necessary. - Event ID: 1001
- Application error logged by Windows Event Viewer, indicating an HMI software crash or unexpected termination.
Restart the HMI application. Check application logs for root cause. Reinstall or update the HMI software if the issue persists. - Event ID: 7034
- A service terminated unexpectedly, typically related to WinCC or a communication service.
Restart the affected service via Windows Service Manager. Check system resources and ensure no conflicts exist with other running processes. - Event ID: 6008
- The previous system shutdown was unexpected, indicating a power loss or system crash.
Check the 24 V DC power supply for stability. Inspect UPS if installed. Review system event logs for preceding errors. - Communication Error
- Loss of communication between the Panel PC and the PLC or field devices via Ethernet or serial interface.
Verify network cable connections and IP address configuration. Check PLC communication settings and ensure matching protocol parameters on both sides. - Watchdog Timeout
- The system watchdog has triggered due to the operating system or application becoming unresponsive.
Perform a controlled restart. Check CPU load and memory usage. Investigate background processes that may be consuming excessive resources. - Hard Disk Error
- SMART diagnostic or Windows event indicating hard disk read/write errors or impending disk failure.
Back up all data immediately. Run disk diagnostics (chkdsk). Replace the hard disk drive or Compact Flash storage medium if errors are confirmed.
Frequently Asked Questions
What is the supply voltage for the 6AV7613-0AA20-0CG0?
The SIMATIC Panel PC 670 (6AV7613-0AA20-0CG0) operates on a 24 V DC power supply, which is standard for industrial panel PCs in this series.
What HMI software is compatible with this Panel PC?
This unit is compatible with Siemens WinCC and WinCC flexible, as well as other SCADA and visualization software packages that run on Microsoft Windows XP Professional.
What communication interfaces are available on this unit?
The 6AV7613-0AA20-0CG0 provides Ethernet (RJ45), multiple USB ports, and RS-232 serial interfaces, enabling connectivity to PLCs, field devices, and office networks.
What is the front panel protection rating of this Panel PC?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for installation in industrial environments.
Can this Panel PC be used with Siemens S7 PLCs?
Yes, the SIMATIC Panel PC 670 can communicate with Siemens S7-300 and S7-400 PLCs via Ethernet using the S7 protocol, as well as through PROFIBUS with an appropriate communication card.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED is illuminated. Inspect the internal fuse and backlight inverter board.
Restore correct supply voltage if out of range. Replace the blown fuse with the correct rating. If the backlight has failed, replace the backlight inverter or the display assembly.
Touchscreen does not respond to input
Check if the touchscreen driver is loaded correctly in Windows Device Manager. Inspect the touchscreen controller cable connection inside the unit.
Reinstall or update the touchscreen driver. Recalibrate the touchscreen via the Windows control panel. If the controller is faulty, replace the touchscreen controller board.
Panel PC fails to boot into Windows
Listen for BIOS POST beep codes and observe any error messages on screen. Check the hard disk or Compact Flash card for errors using BIOS diagnostics.
Run chkdsk to repair file system errors. If the storage medium has failed, replace it and restore the system image from a backup. Reseat RAM modules if POST fails.
Ethernet communication is lost intermittently
Check the Ethernet cable and connector for physical damage. Verify IP address settings and check for IP conflicts on the network. Monitor Windows Event Viewer for network-related errors.
Replace the Ethernet cable if damaged. Assign a static IP address to avoid conflicts. Update the network adapter driver or replace the network adapter if hardware failure is confirmed.
System runs slowly or HMI application freezes
Check CPU and memory utilization in Windows Task Manager. Identify background processes consuming excessive resources. Check available hard disk space.
Terminate unnecessary background processes. Free up disk space by removing unused files. If RAM is insufficient, upgrade memory if the hardware supports it. Consider reinstalling the operating system if performance does not improve.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page