• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AA20-0BE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AA20-0BE0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AA20-0BE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AA20-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC architecture, enabling both operator control and data processing within a single compact device.

    The SIMATIC Panel PC 670 6AV7613-0AA20-0BE0 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation for intuitive operator interaction. It is built around an industrial-grade processor platform and supports standard PC interfaces including USB, serial (RS-232), and Ethernet for connectivity to controllers and networks. The unit is designed for fanless or low-maintenance operation where possible, and its robust steel enclosure provides a high degree of protection for the front panel, rated to IP65, making it suitable for harsh industrial environments.

    The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, process industries, and machine building applications where a full Windows-based PC environment is required at the machine level. Its compatibility with Siemens SIMATIC WinCC and other SCADA/HMI software makes it a natural fit for integration into Siemens-based automation architectures. The device is also used in applications requiring local data logging, recipe management, and complex visualization that exceed the capabilities of standard operator panels.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Windows XP Professional (embedded)

    Common Error Codes & System Events

    Event ID: 100
    System startup failure – the Panel PC failed to complete the boot sequence correctly.
    Check power supply voltage at 24 V DC input. Verify that the operating system image is intact. Restore OS from recovery partition if necessary.
    Event ID: 200
    Ethernet communication lost – the network connection to the controller or SCADA system has been interrupted.
    Check Ethernet cable and switch/hub connections. Verify IP address configuration in Windows network settings. Check controller communication settings.
    Event ID: 300
    Touch screen calibration error – touch input is misaligned or unresponsive.
    Run the touch screen calibration utility from the Windows control panel. If unresponsive, check the touch controller connection internally. Replace touch overlay if calibration fails repeatedly.
    Event ID: 400
    Hard disk or storage device error – the internal storage medium has reported a fault or is not detected.
    Check BIOS/UEFI for storage device detection. Run disk diagnostics. Replace the CompactFlash card or hard disk drive if errors are confirmed.
    Event ID: 500
    Fan failure or thermal warning – internal temperature has exceeded the operating threshold.
    Check that ventilation slots are not blocked. Verify fan operation if present. Clean dust filters. Ensure ambient temperature is within the 0 °C to +50 °C operating range.
    Event ID: 600
    WinCC Runtime communication fault – the HMI software has lost communication with the configured PLC or controller.
    Check PLC connection and communication driver configuration in WinCC. Verify network or MPI/PROFIBUS cable connections. Restart WinCC Runtime and confirm channel settings.

    Frequently Asked Questions

    What operating system does the 6AV7613-0AA20-0BE0 run?

    The SIMATIC Panel PC 670 6AV7613-0AA20-0BE0 runs Windows XP Professional (embedded edition), which is pre-installed and configured for industrial HMI use.

    What is the display size and resolution of this Panel PC?

    This unit features a 15-inch TFT color LCD display with a resolution of 1024 x 768 pixels (XGA format).

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens SIMATIC WinCC and WinCC flexible HMI software, making it suitable for integration into Siemens automation systems.

    What is the supply voltage for the 6AV7613-0AA20-0BE0?

    The unit operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC panel devices.

    What is the front panel protection rating of this Panel PC?

    The front panel of the 6AV7613-0AA20-0BE0 is rated to IP65, providing protection against dust ingress and low-pressure water jets, suitable for industrial cabinet installations.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power input connector. Check whether the power LED is illuminated. Listen for any startup sounds indicating the PC is booting without display output.

    Verify and restore correct 24 V DC supply. If the PC boots but the display is blank, check the internal display cable connection. Replace the backlight inverter or TFT panel if the backlight has failed.

    Touch screen does not respond or responds inaccurately

    Attempt to control the unit using an external USB mouse to determine if the issue is isolated to the touch screen. Check Device Manager in Windows for touch controller errors.

    Recalibrate the touch screen using the calibration utility in the Windows Control Panel. If the touch overlay is physically damaged or the controller is faulty, replace the touch screen assembly.

    Panel PC fails to boot into Windows

    Observe the boot sequence on screen. Check BIOS settings to confirm the correct boot device is selected. Attempt to boot from the recovery partition.

    Restore the operating system from the factory recovery partition. If the storage medium (CompactFlash or HDD) is faulty, replace it and reinstall the OS using the Siemens recovery media.

    Ethernet communication to PLC is intermittent or lost

    Check the Ethernet cable and verify link LEDs on the switch and the Panel PC. Ping the PLC from the Panel PC command prompt to test connectivity. Review WinCC communication channel logs for error messages.

    Replace the Ethernet cable if damaged. Assign a static IP address to avoid DHCP conflicts. Reconfigure the WinCC communication driver and ensure the PLC program and HMI project use matching connection parameters.

    Unit overheats and shuts down unexpectedly

    Check the ambient temperature around the panel installation. Inspect ventilation openings for blockages or dust accumulation. Review Windows Event Viewer for thermal shutdown events.

    Clean all ventilation openings and ensure the panel cutout provides adequate clearance as specified in the installation manual. Verify that the ambient temperature does not exceed 50 °C. If a cooling fan is fitted, confirm it is operational and replace if faulty.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart