• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AA20-0AJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AA20-0AJ0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AA20-0AJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AA20-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial automation environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7613-0AA20-0AJ0) features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and a touch-sensitive screen for operator interaction. It is built around an industrial-grade PC architecture running on a Windows-based operating system, supporting SIMATIC WinCC and other Siemens visualization software. The unit provides standard PC interfaces including USB, serial (COM), and Ethernet ports, and is designed for front-panel mounting with an IP65-rated front face for protection against dust and water ingress. The robust industrial housing ensures reliable operation in harsh factory environments.

    The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, pharmaceutical, and general manufacturing industries. It is suited for applications requiring a full PC-based HMI platform, such as SCADA visualization, process monitoring, recipe management, and data logging at the machine or line level. Its compatibility with Siemens SIMATIC software and standard industrial communication protocols makes it a practical choice for integration into existing Siemens automation architectures.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM)
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly or a critical system file is missing or corrupted.
    Check the hard disk or CompactFlash card for errors. Reinstall or restore the operating system image using the Siemens recovery media.
    Event ID: 1000
    Application fault — the HMI or visualization software (e.g. WinCC) has crashed or encountered an unhandled exception.
    Check the Windows Event Viewer for details. Reinstall or repair the WinCC or HMI runtime software. Ensure software version compatibility.
    Hardware Error: Fan
    Cooling fan failure or fan speed below threshold detected by system monitoring.
    Inspect and clean the cooling fan. Replace the fan unit if it is not spinning or is running below rated speed to prevent thermal shutdown.
    Hardware Error: Temperature
    Internal system temperature has exceeded the permissible operating limit.
    Check ambient temperature and ensure it is within the 0–45 °C operating range. Clean air vents and verify fan operation. Check panel enclosure ventilation.
    Hardware Error: Battery
    CMOS/RTC backup battery voltage is low or battery has failed, causing loss of BIOS settings and real-time clock data.
    Replace the internal CMOS battery (typically a CR2032 lithium coin cell). Re-enter BIOS settings and synchronize the system clock after replacement.
    Communication Error: Ethernet
    Loss of Ethernet network connection or failure to establish communication with the PLC or SCADA server.
    Check Ethernet cable and switch/hub connections. Verify IP address configuration and network settings. Check PLC communication driver configuration in WinCC.
    Display Error: No Signal
    The display panel shows no image despite the system being powered on, indicating a possible GPU, backlight, or display connection fault.
    Check internal display cable connections. Test with an external monitor via VGA if available. Replace the backlight inverter or display panel if the internal display remains blank.
    Storage Error: HDD/CF
    Hard disk drive or CompactFlash storage device is not detected or has reported read/write errors.
    Check physical connection of the storage device. Run a disk diagnostic. Replace the HDD or CompactFlash card and restore the system image from backup media.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 (6AV7613-0AA20-0AJ0) run?

    The SIMATIC Panel PC 670 is designed to run Windows XP Professional or Windows 2000 Professional as its operating system, depending on the configuration ordered. It supports Siemens SIMATIC WinCC and ProTool/Pro runtime software.

    What is the supply voltage for the 6AV7613-0AA20-0AJ0?

    This Panel PC operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.

    What is the display size and resolution of this Panel PC?

    The 6AV7613-0AA20-0AJ0 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA format).

    Is the front panel of the 6AV7613-0AA20-0AJ0 protected against dust and water?

    Yes, the front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets. The rear of the unit is rated IP20.

    What communication interfaces are available on this unit?

    The unit provides Ethernet (RJ45) for network and PLC communication, USB ports for peripherals and data transfer, and RS-232 serial (COM) ports for legacy device connectivity.

    Troubleshooting

    Display remains blank after power is applied

    Check that 24 V DC is present at the power supply connector. Measure voltage at the internal power supply output. Inspect the display backlight inverter and internal display cable connections.

    If supply voltage is correct, replace the backlight inverter board or the internal display cable. If the system does not boot at all, check the storage device and attempt to restore the OS image from recovery media.

    Touchscreen does not respond or registers incorrect touch positions

    Check if the touchscreen is calibrated correctly within the operating system. Inspect the touchscreen controller connection to the motherboard. Check for physical damage or contamination on the screen surface.

    Recalibrate the touchscreen using the Windows calibration utility. If calibration fails, replace the touchscreen overlay or the touchscreen controller board.

    System fails to boot and displays BIOS error or stops at POST screen

    Check the CMOS battery voltage. Verify that the HDD or CompactFlash storage device is detected in BIOS. Check for corrupted boot files on the storage device.

    Replace the CMOS battery and reset BIOS to default settings. If the storage device is not detected, reseat or replace it and restore the operating system from Siemens recovery media.

    WinCC or HMI runtime software crashes repeatedly

    Check Windows Event Viewer for application error logs. Verify that the installed WinCC version is compatible with the operating system version. Check available disk space and RAM.

    Repair or reinstall the WinCC runtime software. Ensure all Siemens software patches and service packs are applied. If hardware memory is faulty, test and replace the RAM module.

    Ethernet communication to PLC is lost intermittently

    Check the Ethernet cable and connector for damage or loose fit. Verify the IP address and subnet configuration in Windows network settings. Check the WinCC communication driver channel settings.

    Replace the Ethernet cable if damaged. Assign a static IP address to avoid DHCP conflicts. Reconfigure the WinCC communication driver and verify the PLC connection parameters match the project configuration.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart