Siemens 6AV7613-0AA20-0AG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA20-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC platform, providing both operator interface and computing functionality in a single compact enclosure.
The SIMATIC Panel PC 670 (6AV7613-0AA20-0AG0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation for intuitive operator interaction. It is equipped with an Intel Celeron processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB, serial (RS-232), and Ethernet ports, and is built to withstand industrial environments with a front panel protection rating of IP65. The fanless or low-maintenance design options reduce maintenance requirements in continuous operation scenarios.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a robust, integrated PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its compatibility with Siemens SIMATIC software and standard PC peripherals makes it a versatile platform for both visualization and data acquisition tasks.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input/Operating Voltage | 24 V DC |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
Check the hard disk or CompactFlash card for errors. Reinstall or restore the operating system image using the recovery partition or external media. - Event ID: 200
- Watchdog timeout — the system watchdog has triggered a reset due to application software not responding within the defined time window.
Investigate the HMI application for software hangs or infinite loops. Increase the watchdog timeout in the BIOS/system settings if appropriate, or update the application software. - Event ID: 300
- Fan failure — the system cooling fan has stopped or is operating below the minimum speed threshold.
Inspect and clean the fan assembly. Replace the fan if it is defective to prevent thermal shutdown. - Event ID: 400
- Temperature warning — the internal system temperature has exceeded the warning threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters and verify that the cooling fan is operational. - Event ID: 500
- Hard disk or storage medium error — read/write errors detected on the internal storage device.
Run a disk diagnostic utility. Back up data immediately and replace the hard disk or CompactFlash card as required. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance range. - Event ID: 700
- Network communication error — loss of Ethernet communication with the PLC or SCADA server.
Check Ethernet cable connections and network switch status. Verify IP address configuration and firewall settings on both the Panel PC and the connected controller.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7613-0AA20-0AG0) support?
The SIMATIC Panel PC 670 supports Microsoft Windows XP Professional and Windows XP Embedded, and is compatible with SIMATIC WinCC and other PC-based HMI software packages.
What is the supply voltage for this Panel PC?
The 6AV7613-0AA20-0AG0 operates on a 24 V DC supply voltage.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it suitable for use in environments where dust and water spray may be present.
Can this Panel PC be used with Siemens SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens SIMATIC WinCC visualization software and other SIMATIC HMI software packages.
What communication interfaces are available on this unit?
The 6AV7613-0AA20-0AG0 provides Ethernet (RJ45), RS-232 serial, and USB interfaces for connectivity to PLCs, networks, and peripherals.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED is illuminated. Inspect internal fuses if accessible.
Ensure the supply voltage is stable and within the 24 V DC specification. If the supply is correct but the display remains blank, the internal power supply board or the display backlight inverter may be faulty and require replacement.
Touch screen does not respond or responds inaccurately
Determine whether the issue is a hardware touch panel failure or a driver/calibration problem by checking if the cursor moves correctly in the operating system.
Recalibrate the touch screen using the Windows touch screen calibration utility. If calibration does not resolve the issue, inspect the touch controller connection internally or replace the touch screen assembly.
Panel PC fails to boot or continuously restarts
Observe the boot sequence for error messages. Check the hard disk or CompactFlash card for physical damage or corruption using BIOS diagnostics.
Restore the operating system using the factory recovery image or a backup image stored on external media. Replace the storage medium if it is physically defective.
Ethernet communication lost with PLC or network
Check the Ethernet cable and connector for damage. Verify the link LED on the Ethernet port is active. Confirm IP address and subnet mask settings in Windows Network Settings.
Replace the Ethernet cable if damaged. Reconfigure the network settings to match the plant network. If the onboard Ethernet port is defective, an external USB-to-Ethernet adapter may be used as a temporary measure.
System overheating or unexpected shutdown due to high temperature
Monitor the internal temperature using the SIMATIC Panel PC diagnostic tools or BIOS hardware monitor. Check that ambient temperature is within the 0 to 45 degrees C operating range.
Improve ventilation around the panel enclosure. Clean any dust from ventilation slots and the cooling fan. If the fan is not operating, replace it. Ensure the installation environment meets the specified ambient temperature requirements.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page