Siemens 6AV7613-0AA12-0CF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA12-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and machine control.
The SIMATIC Panel PC 670 (6AV7613-0AA12-0CF0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive screen for operator interaction. It is equipped with an industrial-grade processor and supports standard PC interfaces including USB, serial (RS-232), and Ethernet ports for connectivity to controllers and peripheral devices. The unit operates on a 24 V DC supply and is designed to meet industrial EMC and environmental requirements, with a front panel protection rating suitable for panel mounting in control cabinets.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building industries where a robust, integrated PC-based HMI solution is required. It is compatible with Siemens SIMATIC WinCC and other SCADA/HMI software packages, making it suitable for integration into SIMATIC automation architectures. Typical applications include production line visualization, batch control systems, and operator workstations in industries such as automotive, food and beverage, and chemical processing.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| Mounting | Panel mounting |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Windows XP Embedded / Windows 2000 |
Common Error Codes & System Events
- Event ID: 1000
- Application error – an application process has encountered a fault and was terminated unexpectedly.
Check Windows Event Viewer for details. Reinstall or update the affected HMI application software. Verify software compatibility with the installed OS version. - Event ID: 6008
- Unexpected shutdown – the system was shut down uncleanly, indicating a possible power loss or system crash.
Check the 24 V DC power supply for stability and correct voltage level. Inspect power connectors and cabling. Review event logs for preceding errors. - BIOS POST Error
- Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
Reseat RAM modules and CompactFlash/hard disk connections. Verify hardware compatibility. Replace faulty memory or storage if necessary. - WinCC Runtime Error
- WinCC HMI runtime software has encountered a configuration or communication error and cannot start or maintain connection.
Check project configuration and PLC communication settings. Verify Ethernet connection and IP addressing. Restart WinCC runtime and check license dongle if applicable. - Watchdog Timeout
- The system watchdog has triggered due to the operating system or application becoming unresponsive.
Investigate CPU load and running processes. Check for software loops or memory leaks in the HMI application. Consider increasing watchdog timeout interval or optimizing the application. - Fan Failure Warning
- Internal cooling fan has stopped or is operating below the minimum required speed.
Inspect and clean the fan and ventilation openings. Replace the internal fan if it is not spinning. Ensure ambient temperature is within the specified operating range. - Hard Disk Error
- Read/write error or failure detected on the internal hard disk or CompactFlash storage device.
Back up data immediately if possible. Run disk diagnostics. Replace the hard disk or CompactFlash card and restore the system image. - Network Communication Lost
- Ethernet communication to the PLC or network has been interrupted or cannot be established.
Check Ethernet cable and switch/hub connections. Verify IP address configuration on both the Panel PC and the connected controller. Check for network hardware faults.
Frequently Asked Questions
What display size and resolution does the 6AV7613-0AA12-0CF0 have?
This Panel PC features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA). It includes a resistive touchscreen for operator input.
What operating system does the SIMATIC Panel PC 670 (6AV7613-0AA12-0CF0) run?
The unit supports Windows XP Embedded or Windows 2000, depending on the configuration ordered. It is compatible with Siemens WinCC and other standard PC-based HMI software.
What is the supply voltage for this Panel PC?
The 6AV7613-0AA12-0CF0 operates on a 24 V DC power supply, which is standard for SIMATIC Panel PC installations in industrial control cabinets.
What communication interfaces are available on this unit?
The Panel PC 670 provides Ethernet (RJ45), RS-232 serial, and USB interfaces, enabling connectivity to SIMATIC PLCs, peripheral devices, and network infrastructure.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and WinCC flexible HMI software, making it directly compatible with SIMATIC S7 PLC families.
Troubleshooting
Display remains blank after power on
Check that the 24 V DC supply voltage is present and within tolerance at the power input connector. Verify the backlight is not failed by checking for a faint image on the screen surface.
Confirm power supply output is stable at 24 V DC. If the backlight has failed, the display assembly or inverter board may need replacement. If no power is detected, inspect fuses and wiring.
Touchscreen does not respond or is inaccurate
Determine whether the issue is a complete lack of response or positional inaccuracy. Check if the touchscreen driver is installed and active in the operating system Device Manager.
Recalibrate the touchscreen using the Windows calibration utility. If unresponsive, check the touchscreen controller connection internally. Replace the touchscreen overlay if the surface is physically damaged.
Panel PC fails to boot and shows BIOS error
Observe the BIOS POST messages on screen. Identify whether the error relates to missing RAM, storage device, or other hardware component.
Reseat RAM modules and check CompactFlash or hard disk connections. If the storage device is not detected, replace it and restore the system image from a backup.
HMI application loses communication with PLC intermittently
Check the Ethernet cable and switch connections. Use a network diagnostic tool to monitor packet loss or latency between the Panel PC and the PLC.
Replace suspect Ethernet cables and ensure the switch port is functioning correctly. Verify IP address and subnet mask settings. Update network adapter drivers if necessary.
System overheats and shuts down unexpectedly
Check the ambient temperature around the panel and verify that ventilation openings are not blocked. Inspect the internal cooling fan for operation.
Clean dust from ventilation slots and fan blades. Ensure the installation environment does not exceed 45 °C. Replace the internal fan if it is not operating correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page