• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AA12-0BJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AA12-0BJ0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AA12-0BJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AA12-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7613-0AA12-0BJ0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 256 colors. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard PC interfaces including USB, serial (RS-232), parallel, and Ethernet ports, enabling integration with a wide range of automation and control systems. It is designed for front-panel mounting with an IP65-rated front bezel, protecting against dust and water ingress in industrial settings.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications across industries such as automotive, food and beverage, chemical processing, and general factory automation. Its rugged industrial design and compatibility with Siemens SIMATIC software make it suitable for use as a central visualization station on production lines, as an operator interface for complex machinery, and as a data acquisition and monitoring terminal in process plants.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT LCD
    Display Colors 256 colors
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), RS-232, USB, Parallel (LPT)
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5% to 95% (non-condensing)
    Mounting Front panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Windows XP / Windows 2000

    Common Error Codes and System Events

    Event ID: 1000
    Application error – a software application has encountered a fatal error and terminated unexpectedly.
    Check the Windows Event Viewer for detailed error information. Reinstall or update the affected HMI application (e.g., WinCC). Verify software compatibility with the installed OS version.
    Event ID: 7026
    Boot-start or system-start driver failed to load during Windows startup.
    Check Device Manager for driver conflicts or missing drivers. Reinstall the relevant hardware driver or restore the system from a known-good backup image.
    Event ID: 6008
    Unexpected system shutdown – the previous system shutdown was unexpected, indicating a possible power loss or system crash.
    Check the 24 V DC power supply for stability and correct voltage. Inspect UPS or power conditioning equipment. Review system logs for preceding errors.
    BIOS POST Error
    Power-On Self-Test failure detected during boot, indicating a hardware fault such as failed RAM or missing boot device.
    Reseat memory modules and check all internal connections. Verify the boot device (CompactFlash or hard disk) is properly connected and functional. Replace faulty hardware components as needed.
    WinCC Runtime Error
    SIMATIC WinCC runtime has encountered a configuration or communication error and cannot start or maintain a connection to the PLC.
    Verify the Ethernet or MPI communication settings in WinCC. Check network cabling and PLC availability. Restart the WinCC runtime and review the WinCC diagnostic log files.
    Watchdog Timeout
    The system watchdog has detected that the operating system or application has become unresponsive and has triggered a system reset.
    Investigate CPU load and running processes for resource exhaustion. Update or reinstall the HMI application. If the issue persists, check hardware health including RAM and storage media.
    Drive Read/Write Error
    The system has detected an error reading from or writing to the storage medium (CompactFlash card or hard disk drive).
    Back up all data immediately. Run a disk check utility to identify bad sectors. Replace the CompactFlash card or hard disk drive if errors persist, and restore the system image.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7613-0AA12-0BJ0?

    The SIMATIC Panel PC 670 (6AV7613-0AA12-0BJ0) operates on a 24 V DC power supply, which is standard for Siemens industrial panel PCs.

    What HMI software is compatible with this Panel PC?

    This unit is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other Windows-based HMI and SCADA software packages. It runs a Windows-based operating system (Windows XP or Windows 2000).

    What is the front panel protection rating of the 6AV7613-0AA12-0BJ0?

    The front panel of the SIMATIC Panel PC 670 is rated IP65, providing protection against dust and low-pressure water jets, making it suitable for industrial environments.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), RS-232 serial, USB, and parallel (LPT) interfaces, enabling connectivity to PLCs, networks, and peripheral devices.

    Can this Panel PC be used as a replacement for an older SIMATIC Panel PC 670 unit?

    Yes, the 6AV7613-0AA12-0BJ0 is a direct replacement within the SIMATIC Panel PC 670 series, provided the software configuration and communication settings are correctly transferred to the replacement unit.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is illuminated. If power is confirmed, the internal power supply board or the TFT display/backlight may have failed.

    Replace the backlight inverter or TFT display assembly if the backlight has failed. If no power LED is present, inspect and replace the internal power supply module. Ensure all internal ribbon cable connections to the display are secure.

    Touchscreen does not respond or is inaccurate

    Determine whether the issue is with the resistive touch overlay or the touch controller driver. Check Device Manager in Windows for any touch controller errors. Test with a stylus to rule out surface contamination.

    Recalibrate the touchscreen using the Windows touchscreen calibration utility. Clean the touch surface with a soft, dry cloth. If calibration does not resolve the issue, replace the touch overlay or the touch controller board.

    System fails to boot and displays a BIOS error or stops at POST

    A failed storage medium (CompactFlash card or HDD), corrupted OS, or failed RAM module is the most likely cause. Enter BIOS setup to verify that the boot device is detected.

    Reseat or replace the CompactFlash card or hard disk drive. If the boot device is detected but the OS is corrupted, restore the system from a backup image. Replace RAM modules if memory errors are reported during POST.

    Loss of communication between the Panel PC and the PLC

    Check the Ethernet or serial cable connections between the Panel PC and the PLC. Verify IP address settings and network configuration in Windows. Check the WinCC communication driver settings for the correct PLC address.

    Replace or reseat the communication cable. Reconfigure the IP address or communication parameters in WinCC to match the PLC settings. Restart the WinCC runtime and the communication driver. If using Ethernet, check the network switch or hub for faults.

    System runs slowly or HMI application freezes intermittently

    High CPU or memory usage caused by background processes, a fragmented or failing storage medium, or insufficient RAM may cause performance degradation. Check Task Manager for resource usage.

    Disable unnecessary Windows background services and startup programs. Defragment the hard disk or replace the CompactFlash card if read/write errors are detected. Ensure the operating system and HMI software are up to date with the latest patches compatible with this hardware.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart