Siemens 6AV7613-0AA12-0AE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA12-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside process control applications.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels and a touch-sensitive screen for operator interaction. It is equipped with an industrial-grade processor and supports standard PC interfaces including USB, serial (RS-232), and Ethernet (RJ45) for integration into plant networks and PLC communication. The unit operates on 24 V DC supply voltage and is built to withstand industrial environments, with a front panel protection rating of IP65 and a robust aluminum housing.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a full PC-based visualization platform is required. Its compatibility with Siemens WinCC and other SCADA packages makes it suitable for complex process visualization, data logging, and recipe management. The panel-mount design allows direct integration into control cabinet doors and operator panels across industries such as automotive, food and beverage, and chemical processing.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet RJ45, RS-232 (COM), USB |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mount |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly, possibly due to a corrupted system partition or failed storage device.
Check the CompactFlash card or hard disk for errors. Restore the system image using the Siemens recovery tool or replace the storage medium. - Event ID: 1000
- Application crash — a user-space application such as WinCC Runtime has terminated unexpectedly.
Review the Windows Event Viewer for the faulting module. Reinstall or update the HMI software. Check for memory or resource conflicts. - Event ID: 7000
- Service failed to start — a required Windows service did not initialize during boot, which may prevent HMI communication or runtime from launching.
Check the Windows Event Log for the specific service name. Verify service dependencies and restart the service manually or reconfigure startup type. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or network device, resulting in no data exchange.
Verify Ethernet cable connections and network configuration. Check IP address settings and ensure the PLC is reachable via ping. Restart the communication driver. - Watchdog Timeout
- The system watchdog has detected that the operating system or application has stopped responding within the defined time window.
Perform a controlled restart of the Panel PC. Investigate CPU load and running processes. If recurring, check for hardware faults or software loops. - Temperature Warning
- Internal temperature sensor has detected that the unit is operating above the recommended threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean any dust from ventilation slots. Verify the cooling fan operation if applicable. - Storage Device Error
- Read/write error detected on the internal CompactFlash card or hard disk drive.
Back up all data immediately. Run a disk check utility. Replace the CompactFlash card or hard disk and restore the system image from backup. - Power Supply Fault
- The 24 V DC supply voltage is out of tolerance, causing the Panel PC to shut down or fail to start.
Measure the supply voltage at the power connector. Ensure the supply is within the specified 24 V DC range. Check wiring and the external power supply unit.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7613-0AA12-0AE0) run?
The SIMATIC Panel PC 670 runs Microsoft Windows XP Embedded or Windows 2000, depending on the specific configuration ordered. This allows it to run standard PC-based HMI and SCADA software such as Siemens WinCC.
What is the supply voltage for this Panel PC?
The 6AV7613-0AA12-0AE0 operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.
Is the 6AV7613-0AA12-0AE0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other PC-based HMI software, making it fully compatible with Siemens automation architectures including S7-300 and S7-400 PLCs.
What is the front panel protection rating of this unit?
The front panel of the 6AV7613-0AA12-0AE0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial environments.
Can the internal storage medium be replaced or upgraded?
Yes, the SIMATIC Panel PC 670 uses a CompactFlash card or hard disk drive as its storage medium, both of which can be replaced. Siemens provides system image recovery tools to restore the software after a storage replacement.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the supply voltage directly at the power input connector of the unit. Check the external power supply output and all wiring connections for continuity.
Ensure the 24 V DC supply is within tolerance and the connector is properly seated. If voltage is correct but the unit does not start, inspect the internal fuse and replace if blown. If the fault persists, the internal power supply board may require replacement.
Display is blank but the unit appears to be running (LEDs active)
Check display brightness settings in the BIOS or operating system. Verify that the display cable connection between the mainboard and the display panel is secure internally.
Adjust display brightness via the software or BIOS settings. If the display remains blank, the TFT panel or the display inverter board may be faulty and should be replaced.
Touchscreen does not respond or registers incorrect touch positions
Check whether the touchscreen driver is correctly installed in the operating system. Perform a touchscreen calibration using the Siemens or Windows calibration utility.
Recalibrate the touchscreen via the control panel utility. If calibration does not resolve the issue, check the touchscreen controller connection. Replace the touchscreen overlay if it is physically damaged.
Loss of communication with PLC or network devices
Verify the Ethernet cable is connected and the link LED on the RJ45 port is active. Check the IP address configuration of the Panel PC and confirm it matches the network subnet.
Correct any IP address or subnet mask mismatches. Replace the Ethernet cable if damaged. Restart the communication driver or WinCC project. If the network adapter is not detected, reinstall the network driver or replace the mainboard.
System freezes or reboots unexpectedly during operation
Check the Windows Event Viewer for critical errors or application crashes. Monitor CPU and memory usage to identify resource exhaustion. Check ambient temperature around the unit.
Close unnecessary background applications to free system resources. Ensure the operating environment is within the specified temperature range. If the issue is software-related, reinstall the HMI application. If hardware-related, test the RAM modules and replace if faulty.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page