• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AF32-0CG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AF32-0CG0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AF32-0CG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AF32-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, offering flexibility for both standard and custom SCADA or HMI software deployments.

    The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels and is equipped with a touch-sensitive screen for operator interaction. It runs on a Windows-based operating system and is built around an x86-compatible processor platform, supporting standard PC interfaces including USB, serial (RS-232), and Ethernet for network connectivity. The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress in industrial environments.

    This Panel PC is widely used in manufacturing, process automation, and machine tool industries where a robust, panel-integrated PC solution is required. Its compatibility with Siemens SIMATIC WinCC and other standard HMI software packages makes it suitable for integration into existing Siemens automation architectures. The industrial-grade construction and fanless or low-noise cooling options make it appropriate for continuous operation in factory floor environments.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), USB, RS-232
    Operating System Windows XP / Windows 2000 (factory configurable)
    Mounting Panel mounting (front flush)
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Certifications CE, UL
    Series/Product Family SIMATIC Panel PC 670

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST.
    Check hard disk or CompactFlash card integrity. Verify boot device is correctly configured in BIOS. Replace storage medium if corrupted.
    Event ID: 200
    Watchdog timeout triggered — application software stopped responding.
    Restart the HMI application. Check for software conflicts or memory leaks. Update or reinstall the HMI runtime software.
    Event ID: 300
    Communication loss to PLC or controller over Ethernet or serial interface.
    Verify network cable connections and IP address configuration. Check PLC communication settings and ensure matching protocol parameters.
    Event ID: 400
    Touchscreen calibration error — touch input not responding correctly.
    Perform touchscreen recalibration via the Windows control panel or SIMATIC HMI configuration tool. Clean the screen surface and check for physical damage.
    Event ID: 500
    Internal temperature warning — device operating above recommended thermal threshold.
    Check ventilation around the panel cutout. Clean any dust filters or ventilation slots. Verify ambient temperature is within specification.
    Event ID: 600
    Power supply undervoltage detected — supply voltage below operational threshold.
    Measure the 24 V DC supply at the power connector. Ensure the power supply unit is rated for the load and check wiring for voltage drop.
    Event ID: 700
    Hard disk or storage device read/write error.
    Run a disk check utility. Back up data and replace the hard disk or CompactFlash card if errors persist. Restore the operating system image.

    Frequently Asked Questions

    What operating voltage does the 6AV7612-0AF32-0CG0 require?

    This Panel PC operates on a 24 V DC power supply. Ensure the supply is stable and within the specified tolerance range to avoid undervoltage faults.

    What is the IP protection rating of this Panel PC?

    The front panel of the 6AV7612-0AF32-0CG0 carries an IP65 rating, providing protection against dust and low-pressure water jets. The rear of the unit is not rated to the same level.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and WinCC flexible HMI software, making it suitable for integration into Siemens automation systems.

    What communication interfaces are available on this unit?

    The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces for connectivity to PLCs, networks, and peripheral devices.

    Can the operating system be reinstalled or upgraded on this Panel PC?

    Yes, the operating system can be reinstalled using a Siemens-provided recovery image. It is recommended to use the original Siemens OS image to ensure driver and hardware compatibility.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector. Verify the power LED status. Measure voltage at the internal power supply output to the display backlight.

    Ensure the 24 V DC supply is within tolerance. If the backlight has failed, the display inverter or backlight lamp may need replacement. If no power LED is present, inspect internal fuses and the power supply module.

    Touchscreen does not respond or registers incorrect touch positions

    Attempt to operate the unit using a connected USB mouse or keyboard to isolate whether the issue is with the touchscreen or the software. Check Device Manager for touchscreen controller errors.

    Recalibrate the touchscreen through the Windows control panel. If calibration fails, check the touchscreen controller connection internally. Replace the touchscreen assembly if the controller is faulty.

    Unit fails to boot and displays a BIOS or POST error

    Check the storage device (hard disk or CompactFlash card) for errors. Enter BIOS setup to verify boot order and hardware detection. Listen for POST beep codes indicating hardware failure.

    Replace the storage medium and restore the Siemens OS image. If the issue persists after storage replacement, inspect RAM modules and reseat them. Contact Siemens support if a motherboard fault is suspected.

    Loss of communication with the connected PLC

    Verify Ethernet cable integrity and connection at both ends. Check the IP address configuration on the Panel PC and confirm it matches the network subnet. Ping the PLC from the Panel PC to test connectivity.

    Correct any IP address mismatches. Replace the Ethernet cable if faulty. Ensure the correct communication driver and protocol settings are configured in the HMI software project.

    Panel PC overheating or shutting down unexpectedly

    Check the ambient temperature around the installation. Inspect ventilation slots and any cooling fans for blockage or failure. Review the system event log for thermal warning entries.

    Improve airflow around the panel cutout by ensuring minimum clearance distances are observed. Clean dust from ventilation areas. If a cooling fan is present and has failed, replace it with the correct Siemens spare part.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart