• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AF32-0BJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AF32-0BJ0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AF32-0BJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AF32-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-performance computing platform with a robust industrial enclosure suitable for direct panel installation.

    The 6AV7612-0AF32-0BJ0 features a 12.1-inch TFT color display with a touch-sensitive screen, enabling operator interaction without the need for an external keyboard or mouse. It is equipped with standard PC interfaces including USB and Ethernet ports, and supports communication with Siemens SIMATIC PLCs via PROFIBUS or Industrial Ethernet. The unit runs on a Windows-based operating system and is compatible with Siemens WinCC and other SCADA/HMI software packages. The industrial-grade construction provides resistance to vibration, dust, and moisture in accordance with relevant IEC protection standards.

    The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine building applications where a full PC platform is required at the operator level. It is suitable for use in automotive production lines, chemical processing plants, and packaging machinery where complex visualization, data logging, and recipe management are needed. The combination of a standard PC architecture with industrial hardening makes it appropriate for environments where both computing flexibility and operational reliability are essential.

    Technical Specifications

    Display Size 12.1 inch
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), USB
    Series/Product Family SIMATIC Panel PC 670
    Mounting Panel mounting
    Certifications CE, UL
    Operating System Windows XP Embedded / Windows 2000

    Common Error Codes & System Events

    Event ID: 1000
    Application error – an application process has terminated unexpectedly on the Panel PC operating system.
    Check the Windows Event Viewer for details on the faulting application. Restart the application or reinstall the HMI software if the error persists.
    Event ID: 7026
    A boot-start or system-start driver failed to load during Windows startup.
    Check Device Manager for driver conflicts. Reinstall or update the relevant driver. Verify hardware connections for any expansion cards.
    Event ID: 6008
    The previous system shutdown was unexpected, indicating a possible power loss or system crash.
    Check the 24 V DC power supply for stability and correct voltage levels. Inspect the power connector and wiring for loose connections.
    Communication Error
    Loss of communication between the Panel PC and the connected PLC via PROFIBUS or Industrial Ethernet.
    Verify network cable connections and IP address configuration. Check PLC communication settings and ensure the correct driver is configured in WinCC or the HMI project.
    Watchdog Timeout
    The system watchdog has detected that the operating system or application has stopped responding within the defined time window.
    Restart the Panel PC. If the fault recurs, check CPU load and available memory. Consider reinstalling the operating system or HMI application.
    Hard Disk Error
    The internal hard disk or Compact Flash storage device has reported a read/write error or is not detected at boot.
    Check BIOS settings to confirm the storage device is detected. Replace the hard disk or Compact Flash card if hardware failure is confirmed. Restore the system image from backup.
    Temperature Warning
    Internal temperature sensor has detected that the Panel PC is operating above the recommended thermal threshold.
    Check that ventilation slots are not blocked. Verify ambient temperature is within the 0 °C to 45 °C operating range. Clean any dust from cooling vents and check fan operation if applicable.

    Frequently Asked Questions

    What display size does the 6AV7612-0AF32-0BJ0 have?

    This Panel PC is equipped with a 12.1-inch TFT color display with a resistive touchscreen for operator input.

    What operating system does this Panel PC run?

    The SIMATIC Panel PC 670 supports Windows XP Embedded or Windows 2000, making it compatible with standard PC-based HMI and SCADA software such as Siemens WinCC.

    What is the supply voltage for this unit?

    The 6AV7612-0AF32-0BJ0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45) and USB interfaces as standard. Communication with Siemens PLCs is supported via Industrial Ethernet or PROFIBUS using appropriate interface cards or adapters.

    What is the front panel protection rating of this device?

    The front panel of the 6AV7612-0AF32-0BJ0 meets IP65 protection, making it resistant to dust ingress and water jets, suitable for industrial panel installation.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power input connector. Check whether the power LED or any system indicator is active. Verify the backlight is not simply dimmed via software settings.

    Restore correct 24 V DC supply if voltage is out of range. If supply is correct and the display remains blank, the backlight inverter or the TFT display panel may require replacement.

    Touchscreen does not respond or responds inaccurately

    Check whether the touchscreen is physically damaged or contaminated. Attempt to recalibrate the touchscreen using the Windows control panel or the Siemens calibration utility.

    Clean the touchscreen surface with a soft cloth. Recalibrate using the touchscreen calibration tool. If the issue persists, the resistive touch overlay may need to be replaced.

    Panel PC fails to boot or hangs at startup

    Observe the boot sequence for error messages. Check BIOS to confirm the storage device (hard disk or Compact Flash) is detected. Listen for unusual sounds from the hard disk.

    If the storage device is not detected, reseat or replace it. Restore the system image from a backup. If BIOS settings have been lost, replace the CMOS battery on the motherboard.

    Loss of communication with PLC

    Verify Ethernet or PROFIBUS cable connections are secure. Check the IP address configuration on the Panel PC and confirm it matches the network settings in the HMI project. Use ping to test network connectivity.

    Correct any IP address mismatches. Replace faulty network cables. Ensure the correct communication driver is installed and configured in the WinCC project. Restart both the Panel PC and the PLC if necessary.

    System runs slowly or HMI application freezes

    Check CPU and RAM utilization using Windows Task Manager. Identify any background processes consuming excessive resources. Check available storage space on the hard disk or Compact Flash card.

    Close unnecessary background applications. Free up storage space by removing unused files. If performance does not improve, consider reinstalling the operating system and HMI application on a new storage device.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart