
Siemens 6AV7612-0AF32-0BE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF32-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a display, computing hardware, and industrial-grade I/O into a single compact panel-mount enclosure.
The SIMATIC Panel PC 670 6AV7612-0AF32-0BE0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP or Windows CE depending on the configuration, providing a familiar environment for SCADA and HMI software such as WinCC flexible or WinCC Runtime. The unit provides standard industrial interfaces including USB, Ethernet (RJ45), serial COM ports, and a CompactFlash slot for storage expansion, along with a front-panel IP65-rated protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine building applications where a robust, panel-integrated PC solution is required. It is suitable for use in automotive production lines, food and beverage processing, chemical plants, and packaging machinery. Its fanless or low-maintenance design options and wide operating temperature tolerance make it appropriate for installation in control cabinets and harsh industrial environments.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet RJ45, USB, RS-232 COM ports, CompactFlash slot |
| Operating System | Microsoft Windows XP Professional |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check CompactFlash card integrity and re-image the operating system if necessary. Verify 24 V DC supply voltage is stable. - Event ID: 101
- Hardware watchdog timeout — the system watchdog has triggered due to a software hang or hardware fault.
Restart the Panel PC. If the fault persists, check CPU load and running processes. Consider reinstalling the HMI runtime application. - Event ID: 200
- Ethernet communication lost — the network connection to the PLC or SCADA server has been interrupted.
Check Ethernet cable and switch connections. Verify IP address configuration and network settings in Windows Device Manager. - Event ID: 201
- MPI/PROFIBUS communication error — communication with the connected Siemens PLC via MPI or PROFIBUS has failed.
Check the communication cable and connector. Verify the bus address and baud rate settings in WinCC or the communication driver configuration. - Event ID: 300
- CompactFlash storage error — read/write error detected on the CompactFlash memory card.
Replace the CompactFlash card with a compatible industrial-grade card and restore the system image from backup. - Event ID: 400
- Temperature warning — internal system temperature has exceeded the recommended operating threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean any dust from ventilation openings and verify the cooling concept of the control cabinet. - Event ID: 500
- Touch screen calibration error — the touch screen is not responding correctly or is misaligned.
Run the touch screen calibration utility from the Windows Control Panel or the SIMATIC Panel PC configuration tool. If the problem persists, check the touch controller ribbon cable connection. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance range.
Frequently Asked Questions
What operating system does the 6AV7612-0AF32-0BE0 run?
This Panel PC 670 variant runs Microsoft Windows XP Professional as its operating system, which supports Siemens WinCC Runtime and WinCC flexible for HMI visualization.
What is the display size and resolution of this panel?
The unit features a 12-inch TFT color LCD with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen interface.
What is the front panel protection rating of the 6AV7612-0AF32-0BE0?
The front panel of this unit is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial environments.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, RS-232 serial COM ports, and a CompactFlash slot. Additional communication via MPI or PROFIBUS is possible through optional expansion cards.
Is the 6AV7612-0AF32-0BE0 compatible with Siemens WinCC?
Yes, this Panel PC is compatible with Siemens WinCC Runtime and WinCC flexible, which are the standard HMI software platforms used with SIMATIC Panel PCs.
Troubleshooting
Display remains blank after power on
Check that the 24 V DC supply voltage is present and within tolerance at the power connector. Verify that the power LED indicator is illuminated. Measure voltage at the internal power distribution points if accessible.
Restore the supply voltage to the correct level. If the display backlight has failed, the backlight inverter or the display assembly may need replacement. Re-seat all internal connectors if the unit has been recently serviced.
Touch screen does not respond or responds inaccurately
Attempt to operate the unit using a USB mouse to determine if the issue is isolated to the touch screen. Check Device Manager in Windows for touch controller errors or missing drivers.
Run the touch screen calibration utility from the Windows Control Panel. If calibration does not resolve the issue, check the ribbon cable connection between the touch panel and the controller board. Replace the touch screen overlay if physically damaged.
Panel PC fails to boot or continuously restarts
Observe the boot sequence on the display. Check whether the system halts at the BIOS screen or during Windows startup. Connect a USB keyboard to access BIOS settings or Safe Mode.
Check the CompactFlash card for errors using a card reader and disk utility. Re-image the CompactFlash card with a valid system image. If the hardware watchdog is triggering the restart, verify that the HMI runtime application is starting correctly.
Ethernet communication to PLC is lost intermittently
Check the Ethernet cable and RJ45 connector for physical damage. Use the Windows network diagnostics or ping command to test connectivity to the PLC or network switch.
Replace the Ethernet cable if damaged. Verify the IP address, subnet mask, and gateway settings in Windows Network Connections. Check the network switch port and ensure the PLC communication driver is configured with the correct connection parameters.
System runs slowly or HMI application freezes
Open Windows Task Manager to check CPU and memory utilization. Identify any background processes consuming excessive resources. Check available storage space on the CompactFlash card.
Disable unnecessary startup programs and background services. Ensure the CompactFlash card has sufficient free space. If the card is nearly full, archive historical data and clear temporary files. Consider upgrading to a higher-capacity CompactFlash card if storage is consistently insufficient.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page



