Siemens 6AV7612-0AF32-0AJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF32-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit integrates a flat-panel display with a built-in computing platform, providing a compact all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AF32-0AJ0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP Professional or Windows XP Embedded, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), and is built to withstand industrial environments with a front panel protection rating of IP65. An integrated CompactFlash slot and hard disk drive option provide flexible storage configurations.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, integrated PC-based HMI solution is required. Its fanless front panel design and industrial-grade construction make it suitable for installation in control cabinets and operator panels in environments with dust, moisture, and vibration. Typical applications include SCADA visualization, production line monitoring, and integration with Siemens SIMATIC S7 PLC systems via PROFIBUS or Industrial Ethernet.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 65,536 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 90 W |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet (RJ45), USB 2.0, RS-232, RS-422/RS-485 |
| Operating System | Windows XP Professional / Windows XP Embedded |
| Processor | Intel Celeron |
| Storage | CompactFlash slot, optional HDD |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the CompactFlash card or hard disk for integrity. Reboot the device and verify the OS installation. Replace storage media if corrupted. - Event ID: 200
- Watchdog timeout — the application software did not respond within the watchdog monitoring interval.
Restart the HMI application. Check for software hangs or excessive CPU load. Update or reinstall the HMI runtime software if the issue persists. - Event ID: 300
- Communication loss to PLC — the Panel PC lost its connection to the configured SIMATIC S7 controller.
Check Ethernet or PROFIBUS cabling and connectors. Verify IP address configuration and PLC availability. Restart the communication driver in WinCC. - Event ID: 400
- Touchscreen calibration error — the touch input is misaligned or unresponsive.
Run the touchscreen calibration utility from the Windows Control Panel. If unresponsive, check the touch controller connection internally or replace the touch overlay. - Event ID: 500
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the permissible operating range.
Measure the supply voltage at the power connector. Ensure the supply is within 18–30 V DC. Check wiring and the external power supply unit. - Event ID: 600
- Fan failure or overtemperature warning — internal temperature has exceeded the permissible operating limit.
Check ambient temperature and ventilation around the panel. Clean any air vents. Verify that the unit is not installed in a location exceeding 50 °C. - Event ID: 700
- Hard disk or CompactFlash read/write error — a storage access failure has been detected.
Run a disk check utility (chkdsk) on the storage device. Back up data and replace the CompactFlash card or hard disk if errors persist. - Event ID: 800
- USB device error — a connected USB peripheral is not recognized or has caused a system fault.
Disconnect and reconnect the USB device. Try a different USB port. Ensure the USB device driver is correctly installed under the operating system.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AF32-0AJ0?
The unit operates on 24 V DC, with a permissible range of approximately 18 V DC to 30 V DC.
What HMI software is compatible with this Panel PC?
The SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other PC-based SCADA and visualization software packages that run on Windows XP.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AF32-0AJ0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for panel-mount installation in industrial environments.
Can this Panel PC communicate with SIMATIC S7 PLCs?
Yes, the unit supports communication with SIMATIC S7 controllers via Industrial Ethernet (TCP/IP) and can also be configured for PROFIBUS connectivity depending on the installed communication options.
What operating system does the 6AV7612-0AF32-0AJ0 run?
The device runs Microsoft Windows XP Professional or Windows XP Embedded, depending on the specific configuration ordered.
Troubleshooting
Display remains blank after power is applied
Check that 24 V DC is present at the power supply connector. Verify the supply voltage is within the 18–30 V DC range. Inspect internal fuses if accessible.
Restore correct supply voltage. If voltage is correct and display remains blank, the internal power supply board or backlight inverter may require replacement.
Touchscreen does not respond or registers incorrect touch positions
Attempt to recalibrate the touchscreen using the Windows Control Panel calibration tool. Check for physical damage or contamination on the touch surface.
Perform a full touchscreen recalibration. Clean the screen surface. If the issue persists after recalibration, the touch controller or overlay assembly may need to be replaced.
Panel PC fails to boot or continuously restarts
Check the CompactFlash card or hard disk for errors using a disk check utility. Verify that the OS installation is intact and that no corrupted system files are present.
Replace the CompactFlash card with a new one and restore the OS image. If using a hard disk, replace it and reinstall the operating system and HMI software.
Loss of communication with the SIMATIC S7 PLC
Verify Ethernet cable connections and check that the Panel PC IP address and PLC IP address are correctly configured and on the same network subnet. Ping the PLC from the Panel PC.
Correct any IP address mismatches. Replace faulty Ethernet cables or switch ports. Restart the WinCC communication driver or reboot the Panel PC if the connection cannot be re-established.
Overtemperature warning or unexpected shutdown due to heat
Check the ambient temperature around the installation. Verify that ventilation slots are not blocked. Monitor internal temperature via the BIOS or system monitoring tools.
Improve cabinet ventilation or add cooling. Ensure the ambient temperature does not exceed 50 °C. Clean any dust from ventilation areas and verify that the unit is mounted with adequate clearance.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page