Siemens 6AV7612-0AF32-0AE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF32-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. The unit integrates a flat-panel display with a built-in computing platform, providing a compact all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 6AV7612-0AF32-0AE0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP or Windows 2000 as its operating system, providing a standard PC-compatible environment. The unit includes multiple communication interfaces such as Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), and supports integration with PROFIBUS and MPI networks via optional expansion cards. It is built to IEC 61131 standards and carries CE certification, with a front panel protection rating of IP65.
The SIMATIC Panel PC 670 is widely used in the automotive, chemical, food and beverage, and manufacturing industries for supervisory control and data acquisition (SCADA), process visualization, and machine control applications. Its panel-mount design and industrial-grade construction make it suitable for installation in control cabinets and operator stations on the factory floor. The combination of standard PC architecture with industrial robustness allows it to run SCADA software such as Siemens WinCC alongside other Windows-based applications.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Protection Rating (Front) | IP65 |
| Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interfaces | Ethernet (RJ45), USB, RS-232, RS-422/RS-485 |
| Operating System | Windows XP / Windows 2000 |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 1000
- Application error in the operating system or HMI runtime software has caused an unexpected termination.
Check Windows Event Viewer for details. Reinstall or repair the HMI runtime software (e.g., WinCC flexible). Ensure all software patches are applied. - Event ID: 7026
- A boot-start or system-start driver failed to load, indicating a hardware driver issue.
Check Device Manager for driver conflicts. Reinstall the appropriate hardware driver. Verify hardware compatibility with the installed OS version. - Event ID: 6008
- The system shut down unexpectedly, indicating a power loss or system crash.
Check the 24 V DC power supply for stability and correct voltage. Inspect internal connections and ensure adequate ventilation to prevent thermal shutdown. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or PROFIBUS/MPI network.
Check network cable connections and termination resistors. Verify correct station address and baud rate settings. Inspect the communication card or adapter for faults. - Hard Disk Error
- The internal hard disk or Compact Flash storage device has failed or is not detected.
Check BIOS settings to confirm the storage device is recognized. Replace the hard disk or Compact Flash card. Restore the system image from a backup. - Display No Signal
- The display panel shows no image despite the system being powered on.
Verify the 24 V DC supply is within tolerance. Check the internal display cable connection. Test with an external monitor via the VGA port if available to isolate display vs. system fault. - Watchdog Timeout
- The system watchdog timer has triggered a reset due to the CPU or application becoming unresponsive.
Check for software processes consuming excessive CPU resources. Ensure the HMI application is correctly configured. Update or reinstall the runtime software and verify hardware integrity.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AF32-0AE0?
The unit operates on a 24 V DC power supply. Ensure the supply is stable and within the specified tolerance to prevent unexpected shutdowns.
What operating system does the SIMATIC Panel PC 670 6AV7612-0AF32-0AE0 run?
This Panel PC is compatible with Microsoft Windows XP Professional and Windows 2000, providing a standard PC environment for running HMI and SCADA software.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AF32-0AE0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial panel installation.
Which HMI software is compatible with this Panel PC?
The unit is compatible with Siemens WinCC and WinCC flexible HMI software, as well as other Windows-based SCADA and visualization applications.
Can the SIMATIC Panel PC 670 communicate with PROFIBUS networks?
Yes, PROFIBUS connectivity can be achieved via an optional PROFIBUS communication card or external adapter. The unit also supports MPI and Ethernet communication natively.
Troubleshooting
Panel PC does not power on after switching on the supply
Measure the 24 V DC supply voltage at the power input connector. Check for blown internal fuses or a faulty power supply unit.
Ensure the supply voltage is within the 24 V DC tolerance range. Replace any blown fuses with the correct rating. If the internal power supply module is faulty, replace it with a compatible spare.
Touch screen is unresponsive or inaccurate
Check if the touch screen driver is correctly installed in Windows Device Manager. Attempt to recalibrate the touch screen using the Windows calibration utility.
Recalibrate the touch screen via the control panel calibration tool. If the issue persists, check the touch screen controller connection internally. Replace the touch screen overlay if the hardware is damaged.
HMI runtime software crashes repeatedly
Check the Windows Event Viewer for application error logs. Verify that the installed runtime software version is compatible with the operating system and hardware.
Reinstall or repair the HMI runtime software. Apply all relevant software updates and patches. If the hard disk is corrupted, restore the system from a backup image or replace the storage device.
No communication with PLC via Ethernet or MPI
Verify the network cable is securely connected and the correct IP address or MPI station address is configured. Use a network diagnostic tool to ping the PLC from the Panel PC.
Correct the IP address or MPI address settings in the HMI project configuration. Replace the network cable if faulty. Check the PLC communication settings to ensure they match the Panel PC configuration.
Display image is distorted or flickering
Check the internal display cable connection between the mainboard and the TFT panel. Verify that the display driver is correctly installed and the resolution is set to 800 x 600.
Reseat the internal display cable connections. Reinstall the display driver in Windows. If the TFT panel itself is damaged, replace it with a compatible 12-inch SVGA panel for the SIMATIC Panel PC 670 series.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page