Siemens 6AV7612-0AF30-0CH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF30-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 6AV7612-0AF30-0CH0 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, providing compatibility with standard SCADA and HMI software packages including WinCC. The unit offers multiple communication interfaces including Ethernet (RJ45) and serial ports, and is designed for front-panel mounting with an IP65-rated front face for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, chemical, and food and beverage industries for machine-level visualization, process monitoring, and data acquisition. Its rugged industrial design and compatibility with Siemens SIMATIC software make it suitable for integration into existing SIMATIC automation architectures. The panel PC format allows direct installation into control cabinet doors or operator panels, reducing cabling complexity and saving floor space.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5 % to 95 % (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mounting (front flush) |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card for errors. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout triggered — the application software did not respond within the defined monitoring interval.
Restart the application. Check for software hangs or excessive CPU load. Update or reinstall the HMI runtime software if the issue persists. - Event ID: 300
- Fan failure or thermal warning — internal cooling fan has stopped or operating temperature exceeded threshold.
Check and clean the cooling fan. Ensure ambient temperature is within specification (0–45 °C). Replace the fan module if defective. - Event ID: 400
- Hard disk or storage media error — read/write failure detected on the internal storage device.
Run a disk check utility. Back up data immediately. Replace the hard disk or CompactFlash card as required. - Event ID: 500
- Network communication error — Ethernet interface failed to establish or maintain a connection.
Check Ethernet cable and switch/hub connections. Verify IP address configuration. Check network adapter settings in the operating system. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the permissible operating range.
Measure the supply voltage at the panel PC power connector. Ensure the power supply unit delivers a stable 24 V DC. Replace or adjust the power supply as needed. - Event ID: 700
- Touch screen calibration error — touch input coordinates are misaligned or the touch controller is not responding.
Perform a touch screen recalibration via the operating system control panel or SIMATIC configuration tool. If unresponsive, check the touch controller ribbon cable connection internally.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AF30-0CH0?
The SIMATIC Panel PC 670 6AV7612-0AF30-0CH0 operates on a 24 V DC supply voltage.
What display size and resolution does this Panel PC have?
This unit features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA).
Is this Panel PC compatible with Siemens WinCC software?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and other SIMATIC HMI software packages, as it runs a Windows-based operating system.
What is the front panel protection rating of the 6AV7612-0AF30-0CH0?
The front panel of this unit is rated IP65, providing protection against dust and water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), RS-232 serial, and USB interfaces for communication and peripheral connectivity.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Measure voltage at the internal power supply board.
Ensure the 24 V DC supply is stable and within tolerance. Replace the internal power supply board if no output voltage is present. If the backlight is faulty, replace the inverter board or the display assembly.
Touchscreen does not respond to input
Check if the operating system has loaded correctly. Verify touch controller driver status in Device Manager. Inspect the ribbon cable connecting the touch panel to the controller board.
Recalibrate the touchscreen via the operating system settings. Reinstall the touch controller driver if missing or corrupted. Replace the touchscreen overlay or controller board if hardware damage is confirmed.
Panel PC fails to boot or shows BIOS error
Check the storage device (hard disk or CompactFlash card) for errors. Listen for POST beep codes and note any error messages on screen. Reseat RAM modules and storage media.
Run a disk diagnostic utility and replace the storage device if errors are found. Restore the operating system from a backup image. If RAM is faulty, replace with compatible modules.
Ethernet communication not working
Verify the Ethernet cable is connected and the link LED on the RJ45 port is active. Check IP address configuration in the operating system. Test connectivity with a ping command.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network. Update or reinstall the network adapter driver if the interface is not recognized.
Unit overheating or fan running at maximum speed
Check the ambient temperature around the panel PC installation. Inspect the cooling fan for blockages or mechanical failure. Verify that ventilation clearances around the unit are maintained.
Clean dust from the fan and ventilation slots. Ensure ambient temperature does not exceed 45 °C. Replace the cooling fan if it is not operating correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page