The Siemens 6AV7612-0AE30-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit integrates computing hardware and a display into a single rugged enclosure suitable for direct panel mounting.
The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP Professional or Windows XP Embedded, providing a familiar PC environment for SCADA and HMI software such as Siemens WinCC. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is built to withstand industrial operating conditions with a wide operating temperature range and high vibration resistance.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI platform is required. Its panel-mount design makes it suitable for integration into control cabinets and operator stations in industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. The combination of standard PC architecture with industrial-grade construction allows it to run complex visualization and data acquisition applications reliably in continuous operation.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 px (XGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Processor | Intel Celeron M |
| Operating System | Windows XP Professional / Windows XP Embedded |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 90 W |
| Communication Interface | 2x USB 2.0, 1x Ethernet RJ45 (10/100 Mbit/s), 1x RS-232 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Protection Rating | IP65 (front), IP20 (rear) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cUL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the integrity of the OS installation. Restore or reinstall the operating system image using the recovery partition or a Siemens recovery CD. - Event ID: 1001
- Application crash or unexpected software termination detected by Windows Error Reporting.
Review the Windows Event Viewer for details. Update or reinstall the affected HMI application (e.g., WinCC). Check for memory or hardware faults. - BIOS POST Error
- Hardware self-test failure during Power-On Self-Test, indicating a memory, CPU, or peripheral fault.
Reseat RAM modules and check all internal connectors. If the error persists, replace the defective hardware component identified in the POST message. - Watchdog Timeout
- The system watchdog timer has expired, indicating the operating system or application has become unresponsive.
Investigate CPU load and running processes. Ensure the HMI application is correctly configured. Restart the system and check for software deadlocks or hardware faults. - Fan Failure Warning
- The system cooling fan has stopped or is running below the minimum required speed.
Clean or replace the cooling fan. Ensure ventilation openings are not blocked. Check fan connector and power supply to the fan. - Hard Disk Error
- The internal hard disk or CompactFlash storage device has reported a read/write error or is not detected.
Check the storage device connection. Run a disk diagnostic utility. Replace the hard disk or CompactFlash card if errors are confirmed. Restore the OS image from backup. - Temperature Warning
- The internal system temperature has exceeded the defined threshold.
Check ambient temperature and ensure it is within the 0–50 °C operating range. Clean air filters and cooling fans. Verify that the panel cutout ventilation is adequate. - Power Supply Fault
- Input voltage is outside the specified 24 V DC operating range, causing an undervoltage or overvoltage condition.
Measure the supply voltage at the power input connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance. Replace the power supply if faulty.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AE30-0CJ0?
The unit operates on 24 V DC. Ensure the power supply is stable and within the specified voltage tolerance to prevent system faults.
What operating system does the SIMATIC Panel PC 670 (6AV7612-0AE30-0CJ0) run?
This Panel PC is designed to run Microsoft Windows XP Professional or Windows XP Embedded. It is not natively compatible with Windows 7 or later without hardware and driver verification.
Is the 6AV7612-0AE30-0CJ0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC visualization software, which is a common HMI application deployed on this platform.
What is the front panel IP protection rating of this unit?
The front panel of the 6AV7612-0AE30-0CJ0 is rated IP65, providing protection against dust and low-pressure water jets. The rear of the unit is rated IP20.
Can the storage medium be replaced or upgraded on this Panel PC?
The internal storage (hard disk or CompactFlash card depending on configuration) can be replaced. Siemens provides recovery media to restore the operating system image after a storage replacement.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power input connector. Verify the backlight is functioning by shining a light at the screen to check for a faint image. Inspect internal fuses and the power supply board.
Replace the backlight inverter or the display panel if the backlight has failed. If no voltage is present at the input, repair or replace the external power supply. Check and replace any blown internal fuses.
Touchscreen does not respond or registers incorrect touch positions
Check if the touchscreen is enabled in the BIOS and operating system device manager. Inspect the touchscreen ribbon cable connection to the controller board. Verify that the screen surface is clean and free of moisture.
Recalibrate the touchscreen using the Windows calibration utility or the Siemens-provided calibration tool. If calibration fails, replace the touchscreen overlay or the touch controller board.
System fails to boot and displays a BIOS error or stops at POST
Reseat the RAM modules and check all internal cable connections. Attempt to boot from an external recovery medium. Listen for BIOS beep codes that identify the faulty component.
Replace faulty RAM modules or the internal storage device. Restore the operating system using the Siemens recovery CD or recovery partition. If the motherboard is at fault, replace the CPU board assembly.
Ethernet communication is not established with the PLC or network
Check the Ethernet cable and switch port. Verify the IP address configuration in Windows Network Settings. Use the ping command to test connectivity. Check the device manager for driver errors on the network adapter.
Correct the IP address, subnet mask, and gateway settings. Replace the Ethernet cable if damaged. Update or reinstall the network adapter driver. If the onboard NIC is faulty, replace the motherboard or use a USB-to-Ethernet adapter as a temporary measure.
System overheats and shuts down unexpectedly
Check the ambient temperature around the panel. Inspect the cooling fan for dust buildup or failure. Verify that the panel cutout dimensions and ventilation clearances meet Siemens installation requirements.
Clean the cooling fan and ventilation slots with compressed air. Replace the cooling fan if it is not spinning. Ensure the installation environment does not exceed 50 °C ambient temperature. Improve cabinet ventilation if necessary.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page