• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE30-0CH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE30-0CH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE30-0CH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE30-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-resolution display with a robust industrial PC platform, offering a compact all-in-one solution for process visualization and control.

    The SIMATIC Panel PC 670 6AV7612-0AE30-0CH0 features a 12.1-inch TFT LCD display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors, providing clear visualization of process data. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, supporting standard industrial software environments including WinCC and ProTool. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces, enabling integration with Siemens S7 PLCs and third-party controllers. The front panel meets IP65 protection rating, making it resistant to dust and water ingress in industrial settings.

    The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical processing, and food and beverage industries where a full PC-based HMI platform is required. It is suitable for applications demanding complex visualization, data logging, recipe management, and connectivity to plant-level networks. Its panel-mount design and industrial-grade construction make it appropriate for integration into control cabinets and operator stations on the production floor.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Power Consumption 60 W (typical)
    IP/Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232, RS-422/485
    Mounting Panel mount
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
    Check the hard disk or CompactFlash card for errors. Attempt system restore or reinstall the operating system using the recovery partition or backup media.
    Event ID: 200
    Watchdog timeout — the system watchdog has triggered due to a software hang or unresponsive application.
    Restart the Panel PC. Investigate the running application for infinite loops or resource conflicts. Update or reinstall the HMI software if the issue persists.
    Event ID: 300
    Communication error to PLC — loss of connection between the Panel PC and the connected Siemens S7 PLC or third-party controller.
    Check Ethernet or serial cable connections. Verify IP address configuration and network settings. Confirm the PLC is powered and running.
    Event ID: 400
    Touchscreen calibration error — the touchscreen input does not correspond correctly to displayed elements.
    Run the touchscreen calibration utility from the Windows Control Panel or SIMATIC configuration tools. Clean the touchscreen surface and recalibrate.
    Event ID: 500
    Temperature warning — internal temperature has exceeded the recommended operating threshold.
    Check ambient temperature and ensure adequate ventilation around the panel. Clean any dust from ventilation slots. Verify the installation environment is within the 0 °C to 45 °C operating range.
    Event ID: 600
    Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum required level.
    Measure the supply voltage at the power connector. Ensure the power supply unit is rated adequately for the load. Check wiring for excessive voltage drop.
    Event ID: 700
    Hard disk or storage media failure — the system cannot read from or write to the internal storage device.
    Replace the hard disk drive or CompactFlash card. Restore the operating system and HMI application from backup media.
    Event ID: 800
    Graphics driver error — the display output has failed or is showing incorrect rendering due to a driver fault.
    Restart the Panel PC. Reinstall or update the graphics driver. If the display remains faulty, inspect the display cable connection or consider display unit replacement.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 6AV7612-0AE30-0CH0 run?

    This Panel PC is designed to run Windows XP Professional or Windows 2000 Professional, supporting standard Siemens HMI software such as WinCC and ProTool/Pro Runtime.

    What is the supply voltage for this Panel PC?

    The 6AV7612-0AE30-0CH0 operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC 670 units.

    Is this Panel PC compatible with Siemens S7-300 and S7-400 PLCs?

    Yes, the SIMATIC Panel PC 670 supports communication with Siemens S7-300 and S7-400 PLCs via Ethernet (TCP/IP, PROFINET) and MPI/PROFIBUS interfaces when used with appropriate communication cards.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AE30-0CH0 meets IP65 protection, providing full dust protection and resistance to water jets, making it suitable for industrial environments.

    Can the internal storage of this Panel PC be replaced or upgraded?

    Yes, the SIMATIC Panel PC 670 supports replacement of the internal hard disk drive or CompactFlash card. Siemens provides recovery media for reinstalling the operating system and factory software after storage replacement.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power connector with a multimeter. Check the internal fuse and inspect the power supply board for visible damage.

    Ensure the supply voltage is within the specified range. Replace the internal fuse if blown. If the power supply board is faulty, replace the internal PSU module or send the unit for repair.

    Display is blank but the system appears to be running (LEDs active, HDD activity present)

    Check the display cable connection between the mainboard and the TFT panel. Test the backlight inverter by listening for a faint high-frequency sound or measuring inverter output voltage.

    Reseat or replace the display cable. Replace the backlight inverter or the TFT display panel if the backlight has failed. Adjust display brightness settings in the BIOS or Windows display settings.

    Touchscreen input is inaccurate or unresponsive

    Determine whether the issue is mechanical (damaged screen surface) or software-related (calibration drift). Check for physical damage, scratches, or contamination on the touchscreen surface.

    Clean the touchscreen surface with a soft, dry cloth. Run the touchscreen calibration utility in Windows Control Panel. If the touchscreen controller has failed, replace the touchscreen assembly.

    Loss of communication with PLC or network

    Check all Ethernet and serial cable connections. Verify the IP address and subnet mask configuration in Windows Network Settings. Ping the PLC from the Panel PC to test network connectivity.

    Replace faulty cables or connectors. Reconfigure network settings to match the plant network. If using a PROFIBUS or MPI card, check the card seating and driver installation.

    System freezes or reboots unexpectedly during operation

    Check the Windows Event Viewer for application or system errors. Monitor the CPU temperature using a diagnostic utility. Inspect the RAM modules for proper seating.

    Ensure the operating environment is within the specified temperature range. Reseat or replace RAM modules. Reinstall or update the HMI application software. If hardware faults are confirmed, replace the mainboard.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart