• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE22-0AJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE22-0AJ0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE22-0AJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE22-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a high-performance computing platform with a robust flat-panel display in a single integrated housing suitable for control cabinet front-panel installation.

    The SIMATIC Panel PC 670 (6AV7612-0AE22-0AJ0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP Professional or Windows XP Embedded as its operating system. The unit provides standard PC interfaces including USB, RS-232, Ethernet (RJ45), and a parallel port, enabling integration with a wide range of industrial peripherals and control systems. The panel is rated IP65 on the front face, providing protection against dust and water ingress in harsh industrial environments.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI platform is required. Its compatibility with Siemens WinCC and WinCC flexible SCADA and HMI software makes it suitable for complex visualization tasks, data logging, and process monitoring. Industries such as automotive, food and beverage, chemical processing, and general machine building commonly deploy this panel PC for operator interface and supervisory control functions.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT Color LCD
    Display Colors 262,144 colors
    Touch Technology Resistive touchscreen
    Processor Intel Celeron
    Operating System Windows XP Professional / Windows XP Embedded
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 60 W
    Communication Interface Ethernet RJ45, USB, RS-232, Parallel port
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Mounting Panel mounting (front-panel installation)
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to initialize correctly during boot.
    Check the hard disk or CompactFlash card for errors. Attempt a system restore or reinstall the operating system image.
    Event ID: 1000
    Application fault — a WinCC or HMI runtime application has crashed unexpectedly.
    Restart the HMI runtime application. Check the application event log for details and update or reinstall the WinCC runtime software if the issue persists.
    Event ID: 7034
    Service terminated unexpectedly — a Windows service required for HMI operation stopped without warning.
    Open Windows Services manager, identify the failed service, and restart it. Investigate root cause via the Windows Event Viewer.
    Event ID: 1001
    System recovered from a serious error (BugCheck) — a blue screen or kernel fault occurred.
    Check for driver conflicts or hardware faults. Update device drivers and verify RAM integrity using a memory diagnostic tool.
    Event ID: 6008
    Unexpected system shutdown — the Panel PC was shut down improperly, possibly due to a power interruption.
    Verify the 24 V DC power supply stability. Install an uninterruptible power supply (UPS) if power fluctuations are suspected. Check power connector integrity.
    Event ID: 4226
    TCP/IP connection limit reached — the Ethernet communication stack has exceeded its connection limit.
    Review and reduce the number of simultaneous network connections. Check for network loops or misconfigured communication drivers in WinCC.
    Hardware Watchdog Timeout
    The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
    Investigate the cause of the OS hang. Check CPU load, memory usage, and running processes. Ensure the WinCC runtime and Windows services are functioning correctly.

    Frequently Asked Questions

    What operating system does the 6AV7612-0AE22-0AJ0 support?

    The SIMATIC Panel PC 670 (6AV7612-0AE22-0AJ0) supports Microsoft Windows XP Professional and Windows XP Embedded. It is not natively compatible with Windows 7 or later without hardware and BIOS verification.

    What is the supply voltage for this Panel PC?

    The unit operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs in this series.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens WinCC and WinCC flexible HMI/SCADA software, which are the primary visualization platforms used with this hardware.

    What is the front panel protection rating of the 6AV7612-0AE22-0AJ0?

    The front panel is rated IP65, providing complete protection against dust ingress and protection against low-pressure water jets. The rear of the unit is rated IP20.

    What communication interfaces are available on this unit?

    The 6AV7612-0AE22-0AJ0 provides Ethernet (RJ45), USB ports, RS-232 serial, and a parallel port for connecting to PLCs, peripherals, and industrial networks.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is illuminated. Measure voltage at the internal power supply output.

    Ensure the 24 V DC supply is within tolerance. If the supply is correct but the display remains blank, the internal power supply board or the TFT display backlight inverter may have failed and should be replaced.

    Touchscreen does not respond or responds inaccurately

    Check if the touchscreen is recognized in Windows Device Manager. Attempt a touchscreen recalibration using the Siemens touchscreen calibration utility in the Control Panel.

    Recalibrate the touchscreen via the Windows Control Panel calibration tool. If the issue persists, inspect the touchscreen controller connection internally or replace the resistive touchscreen overlay.

    Panel PC fails to boot and shows a black screen with error message

    The CompactFlash card or hard disk may be corrupted or failing. Attempt to boot from an external USB device to isolate the storage device as the fault source.

    Replace the CompactFlash card or hard disk with a new unit and restore the operating system image using the Siemens recovery media or a verified backup image.

    Ethernet communication is not established with the PLC or network

    Check the Ethernet cable and RJ45 connector for physical damage. Verify the IP address configuration in Windows Network Settings and confirm the network switch port is active.

    Reconfigure the IP address settings to match the network subnet. Replace the Ethernet cable if damaged. If the NIC is not detected in Device Manager, the onboard Ethernet controller may require driver reinstallation or hardware replacement.

    WinCC runtime application crashes repeatedly

    Review the Windows Event Viewer Application log for error codes associated with the WinCC process. Check available RAM and CPU usage during runtime operation.

    Ensure the WinCC runtime version is compatible with the installed Windows OS version. Free up system resources by disabling unnecessary background services. Reinstall the WinCC runtime software if application files are corrupted.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart