The Siemens 6AV7612-0AE20-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AE20-0CH0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an industrial-grade processor platform running Microsoft Windows, with interfaces including USB, Ethernet (RJ45), and serial ports for connectivity to PLCs and peripheral devices. The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress in industrial settings.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a full PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its compatibility with Siemens SIMATIC WinCC and other SCADA software makes it a practical choice for complex visualization and data logging tasks.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| IP Protection (Front) | IP65 |
| IP Protection (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | Ethernet RJ45, USB, RS-232/RS-422/RS-485 |
| Mounting | Panel mounting (front flush) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100000
- System startup error — the operating system failed to boot correctly or a critical system file is missing.
Check the hard disk or CompactFlash card for integrity. Reinstall the operating system or restore from a system backup. - Event ID: 110000
- Hardware watchdog timeout — the panel PC application did not respond within the watchdog monitoring period.
Restart the Panel PC. Check the running application for software hangs or excessive CPU load. Update or reinstall the HMI runtime software. - Event ID: 120000
- Fan failure detected — the internal cooling fan has stopped or is running below the required speed.
Inspect and clean the fan. Replace the fan unit if it is defective to prevent thermal shutdown. - Event ID: 130000
- Temperature limit exceeded — the internal temperature of the Panel PC has exceeded the permissible operating threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters and verify fan operation. - Event ID: 140000
- Battery low or battery failure — the CMOS/RTC backup battery voltage is below the required level.
Replace the internal CMOS backup battery with the correct replacement type. After replacement, reconfigure BIOS settings and system time. - Event ID: 150000
- Communication error — loss of communication between the Panel PC and a connected PLC or peripheral device.
Check Ethernet or serial cable connections. Verify network settings, IP address configuration, and PLC communication parameters in the HMI project. - Event ID: 160000
- Storage medium error — read/write error detected on the hard disk or CompactFlash storage device.
Run a disk check utility. Replace the storage medium if errors persist and restore the system image from backup. - Event ID: 170000
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the permissible operating range.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7612-0AE20-0CH0?
The Panel PC 670 (6AV7612-0AE20-0CH0) operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.
What display size and resolution does this Panel PC provide?
This unit features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen input.
What operating system does the SIMATIC Panel PC 670 run?
The SIMATIC Panel PC 670 is designed to run Microsoft Windows (typically Windows XP Embedded or Windows 2000, depending on the configuration ordered). It supports Siemens WinCC and other Windows-based SCADA and HMI software.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AE20-0CH0 carries an IP65 protection rating, making it suitable for environments with dust and water spray.
Is this Panel PC compatible with Siemens SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens SIMATIC WinCC visualization software, as well as other Windows-based HMI and SCADA applications.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Measure voltage at the internal power supply output.
Ensure the 24 V DC supply is stable and correctly connected. If the supply is correct but the display remains blank, the internal power supply board or backlight inverter may be faulty and require replacement.
Touch screen does not respond or is inaccurate
Check if the touch screen is physically damaged or contaminated. Verify that the touch screen driver is correctly installed in the operating system.
Clean the touch screen surface with a soft cloth. Recalibrate the touch screen using the Windows calibration utility. If calibration fails, the touch screen controller or the resistive overlay may need replacement.
Panel PC fails to boot or operating system does not load
Check the storage medium (hard disk or CompactFlash card) for errors using a disk diagnostic tool. Listen for unusual sounds from the hard disk during startup.
Run a disk check and repair utility. If the storage medium is faulty, replace it with a compatible unit and reinstall the operating system and HMI project from backup media.
Loss of communication with connected PLC
Check Ethernet or serial cable connections between the Panel PC and the PLC. Verify IP address settings and communication parameters in the HMI project configuration.
Replace or reseat communication cables. Reconfigure network settings to match the PLC interface parameters. Ensure the correct communication driver is installed and active in the WinCC project.
System overheating or unexpected shutdown due to high temperature
Check the ambient temperature around the panel. Inspect the cooling fan for operation and check air vents for blockage or dust accumulation.
Clean the air vents and fan with compressed air. Ensure the installation environment is within the 0 °C to +45 °C operating temperature range. Replace the cooling fan if it is not operating correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page