Siemens 6AV7612-0AE20-0CG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE20-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface applications, combining computing power with a robust touch-enabled display in a single integrated unit. The Panel PC 670 series is engineered for use in industrial environments where reliability and continuous operation are essential.
The 6AV7612-0AE20-0CG0 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA), supporting touch screen operation for intuitive operator interaction. The unit is based on an x86-compatible processor architecture and runs Microsoft Windows, enabling compatibility with standard SCADA and visualization software including Siemens WinCC. It provides multiple communication interfaces including Ethernet (RJ45) and supports integration into PROFIBUS and PROFINET networks via appropriate interface cards. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front side.
The SIMATIC Panel PC 670 is widely deployed in the automotive, food and beverage, pharmaceutical, and general manufacturing industries. It is typically used as a central visualization and control station on production lines, machine tools, and process control systems where a full PC-based HMI platform is required. Its compatibility with Siemens SIMATIC software ecosystem makes it a natural fit for installations already using S7 PLCs and TIA Portal or STEP 7 engineering environments.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive Touch Screen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | Ethernet RJ45, USB |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100000
- Runtime software startup failure — the WinCC or visualization runtime application failed to start correctly on boot.
Check Windows event log for application errors. Verify that the runtime software license is valid and that the installation is intact. Reinstall runtime if necessary. - Event ID: 110000
- Communication link to PLC lost — the HMI has lost its configured connection to the SIMATIC S7 controller.
Check Ethernet or PROFIBUS cabling and connector integrity. Verify PLC is powered and running. Check network settings and connection parameters in the project configuration. - Event ID: 120000
- Tag acquisition error — one or more configured process tags cannot be read from the controller.
Verify tag addresses in the HMI project match the PLC data block structure. Check communication connection status and ensure the PLC program is running. - Event ID: 130000
- Printer communication error — the configured printer is not responding or is unavailable.
Check printer connection cable and power. Verify printer driver installation in Windows. Reconfigure the printer settings in the HMI project if necessary. - Event ID: 140000
- Archive full warning — the data or alarm archive has reached its configured maximum capacity.
Back up and clear the archive data. Increase the archive size in the project configuration or set up automatic archiving to an external storage location. - Event ID: 150000
- Watchdog timeout — the system watchdog has detected that the runtime application has stopped responding.
Restart the runtime application. If the problem persists, check system resource usage (CPU, RAM) in Windows Task Manager and close unnecessary background processes. - Event ID: 160000
- Hardware fault detected — a hardware component such as the touch screen controller or display backlight has reported an error.
Perform a power cycle. If the fault persists, inspect internal connections and consider replacing the affected hardware component or returning the unit for repair.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AE20-0CG0?
The unit operates on 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices in industrial panel installations.
What is the display size and resolution of this Panel PC?
The 6AV7612-0AE20-0CG0 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA).
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC visualization software, as it runs a Windows operating system on an x86-compatible platform.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AE20-0CG0 meets IP65 protection rating, providing full protection against dust and resistance to water jets.
Can this Panel PC be integrated into a PROFINET network?
Yes, the Panel PC 670 supports Ethernet-based communication and can be integrated into PROFINET networks. PROFIBUS connectivity may also be added via an appropriate expansion card.
Troubleshooting
Display remains blank after power on
Check that 24 V DC supply voltage is present at the power connector. Verify the backlight is not in a sleep or power-saving state by touching the screen or pressing a key.
Restore correct 24 V DC supply if absent. If voltage is correct and display remains blank, the backlight inverter or display panel may be faulty and require replacement.
Touch screen does not respond or is inaccurate
Determine whether the issue is a complete lack of response or positional inaccuracy. Check for physical damage or contamination on the touch surface.
Clean the touch surface with a soft cloth. Recalibrate the touch screen through the Windows control panel or SIMATIC settings. If unresponsive after recalibration, the touch controller or overlay may need replacement.
Unit fails to boot into Windows or runtime software
Observe the boot sequence on screen. Check whether the unit stops at BIOS, Windows boot screen, or during runtime startup. Listen for unusual sounds from internal storage.
Attempt a controlled restart. If the unit fails to boot consistently, the internal CompactFlash card or hard disk may be corrupted or failed. Replace the storage medium and restore the system image from a backup.
Communication with PLC is lost intermittently
Check Ethernet cable integrity and connector seating at both the Panel PC and the network switch or PLC. Monitor for network errors using Windows network diagnostics.
Replace suspect Ethernet cables and ensure connectors are fully seated. Verify IP address configuration matches the project settings. Check for IP address conflicts on the network.
Runtime application crashes or freezes during operation
Check Windows Event Viewer for application error logs. Monitor CPU and RAM usage to determine if system resources are exhausted.
Close unnecessary background applications to free system resources. Ensure the runtime software version is compatible with the installed Windows version. Reinstall the runtime software if crashes persist.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page