Siemens 6AV7612-0AE10-0BF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE10-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. The unit combines a high-performance computing platform with a robust, fanless or fan-cooled enclosure suitable for direct panel mounting.
The SIMATIC Panel PC 670 (6AV7612-0AE10-0BF0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch technology for operator interaction. It is equipped with an Intel Celeron processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard industrial communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), and is designed for 24 V DC supply voltage. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, chemical processing, and packaging. Its panel-mount design allows direct integration into control cabinets and operator stations, while compatibility with Siemens SIMATIC software makes it suitable for use alongside S7-300 and S7-400 PLC systems. The combination of a standard PC architecture with industrial-grade hardware makes it appropriate for applications requiring both HMI functionality and local data processing or logging.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Processor | Intel Celeron |
| Operating System | Microsoft Windows (XP/2000) |
| Communication Interfaces | Ethernet (RJ45), USB, RS-232, RS-422/RS-485 |
| Front Panel Protection | IP65 |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes and System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly or a startup service encountered a fault.
Check the CompactFlash card or hard disk for errors. Verify the OS installation integrity and review Windows Event Viewer logs for the specific failing service. - Event ID: 1001
- Application crash or unexpected shutdown of the HMI runtime software (e.g., WinCC flexible Runtime).
Review the Windows Event Viewer application log for the faulting module. Reinstall or update the HMI runtime software if the issue persists. - Event ID: 7034
- A system service terminated unexpectedly, which may affect HMI communication or data acquisition.
Identify the affected service in the Windows Event Viewer System log and restart it. Check for software conflicts or corrupted service executables. - WinCC Alarm: Connection Error
- Loss of communication between the Panel PC and the connected PLC (e.g., S7-300/S7-400) over Ethernet or MPI.
Verify Ethernet cable connections and network settings. Check PLC IP address configuration and ensure the WinCC communication driver is correctly configured. - WinCC Alarm: Tag Read Error
- One or more process tags cannot be read from the PLC, resulting in invalid or missing values on the HMI display.
Check PLC program for the relevant data blocks and addresses. Verify tag configuration in WinCC and confirm the PLC is in RUN mode. - Hardware Error: Touchscreen Not Responding
- The resistive touchscreen does not register operator input, possibly due to calibration loss or hardware fault.
Recalibrate the touchscreen using the Windows control panel touchscreen calibration utility. If calibration fails, inspect the touch controller connection internally or replace the touch overlay. - Hardware Error: Display Backlight Failure
- The display backlight has failed or dimmed significantly, making the screen difficult or impossible to read.
Check the backlight inverter board and CCFL lamp connections. Replace the backlight inverter or the display assembly if the lamp has reached end of life. - Hardware Error: CompactFlash/HDD Failure
- The storage medium (CompactFlash card or hard disk drive) is not detected or reports read/write errors, preventing OS boot.
Replace the CompactFlash card or HDD with a compatible unit. Restore the OS image from a backup. Ensure the replacement storage meets Siemens specifications for the Panel PC 670.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7612-0AE10-0BF0?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices.
What is the display size and resolution of this Panel PC?
The 6AV7612-0AE10-0BF0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
Which HMI software is compatible with the SIMATIC Panel PC 670?
The Panel PC 670 is compatible with Siemens SIMATIC WinCC and WinCC flexible runtime software, as well as other Windows-based SCADA and visualization applications.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AE10-0BF0 meets IP65 protection, providing full dust protection and resistance to water jets from any direction.
Can this Panel PC communicate with Siemens S7 PLCs?
Yes, the SIMATIC Panel PC 670 supports Ethernet-based communication and can interface with S7-300 and S7-400 PLCs using standard SIMATIC communication drivers configured in WinCC.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector to confirm correct voltage level. Check the internal fuse and inspect the power supply board for visible damage.
Replace the internal fuse if blown. If the power supply board is faulty, replace it with a compatible unit. Ensure the 24 V DC source can supply sufficient current for the Panel PC.
Display is blank but the system appears to be running (LEDs active, HDD activity)
Check the display backlight by shining an external light on the screen to see if an image is faintly visible. Inspect the backlight inverter and display cable connections.
Replace the CCFL backlight lamp or the backlight inverter board. If the display cable is loose or damaged, reseat or replace it. In severe cases, replace the entire display assembly.
Touchscreen input is inaccurate or unresponsive
Attempt touchscreen recalibration via the Windows Control Panel. Check for physical damage to the touch overlay surface and inspect the touch controller cable connection.
Recalibrate the touchscreen using the built-in Windows calibration tool. If recalibration does not resolve the issue, replace the resistive touch overlay panel and reconnect the touch controller cable securely.
HMI runtime software loses communication with the PLC intermittently
Check the Ethernet cable and switch/hub connections between the Panel PC and the PLC. Verify IP address settings and subnet configuration on both devices. Monitor for network errors in Windows Event Viewer.
Replace the Ethernet cable if damaged. Assign static IP addresses to avoid DHCP conflicts. Update the WinCC communication driver and verify the PLC connection parameters match the configured settings.
System boots slowly or fails to boot, with disk read errors reported
Run a disk check utility (chkdsk) on the CompactFlash card or HDD. Listen for unusual sounds from the HDD or check the CompactFlash card for read/write errors using diagnostic software.
Replace the CompactFlash card or HDD with a Siemens-approved replacement. Restore the operating system and HMI software from a verified backup image. Ensure the new storage device is correctly seated in its connector.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page