• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE10-0BE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE10-0BE0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE10-0BE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE10-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC architecture, providing both operator interface and computing functionality in a single device.

    The SIMATIC Panel PC 670 (6AV7612-0AE10-0BE0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology for operator input. It is built around an x86-compatible processor platform and supports standard PC interfaces including USB, serial (RS-232), and Ethernet ports for connectivity to PLCs and higher-level systems. The unit is designed for panel mounting and operates on a 24 V DC supply, with a robust aluminum front frame providing an IP65 protection rating on the front face for resistance to dust and water ingress.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a combined visualization and computing platform is required. Its compatibility with Siemens SIMATIC WinCC and other SCADA software makes it suitable for integration into Siemens-based automation architectures. Industries such as automotive, food and beverage, chemical processing, and general machine building commonly deploy this panel PC for supervisory control and data acquisition tasks.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT Color LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Communication Interfaces Ethernet (RJ45), USB, RS-232 (serial)
    Mounting Panel mounting
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 95% (non-condensing)
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup failure — the Panel PC failed to complete the boot sequence, possibly due to a corrupted operating system or failed storage device.
    Check the hard disk or CompactFlash card for errors. Attempt to restore or reinstall the operating system. Verify power supply stability during boot.
    Event ID: 101
    Operating system not found — the BIOS cannot locate a bootable device or the boot partition is missing.
    Check BIOS boot order settings. Inspect the storage medium (HDD or CF card) for physical damage or corruption. Restore the OS image if necessary.
    Event ID: 200
    Watchdog timeout — the system watchdog has triggered due to an application hang or system overload.
    Identify and terminate the process causing the hang. Check CPU and memory utilization. Update or reinstall the HMI application software if the issue recurs.
    Event ID: 300
    Fan failure detected — the internal cooling fan has stopped or is operating below the minimum speed threshold.
    Inspect and clean the fan for obstructions. Replace the fan unit if it is defective. Ensure ambient temperature is within the specified operating range.
    Event ID: 400
    Temperature warning — internal temperature has exceeded the warning threshold, risking thermal shutdown.
    Check that ventilation clearances around the panel are maintained. Clean any dust filters. Verify ambient temperature is within specification (0 °C to +50 °C).
    Event ID: 500
    Ethernet communication error — loss of network connectivity or failure to establish communication with a PLC or SCADA server.
    Check Ethernet cable connections and network switch status. Verify IP address configuration. Test communication using a ping command to the target device.
    Event ID: 600
    Touchscreen calibration error — the touch input is misaligned or unresponsive, indicating a calibration or hardware fault.
    Run the touchscreen calibration utility from the Windows Control Panel or SIMATIC settings. If the issue persists, inspect the touch controller connection or replace the touchscreen assembly.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 (6AV7612-0AE10-0BE0) run?

    The SIMATIC Panel PC 670 series supports Microsoft Windows XP Professional or Windows XP Embedded as the operating system, depending on the specific configuration ordered. The 6AV7612-0AE10-0BE0 variant is typically supplied with Windows XP Embedded.

    What is the supply voltage for this Panel PC?

    The 6AV7612-0AE10-0BE0 operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 units intended for industrial panel installation.

    Is the SIMATIC Panel PC 670 compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run Siemens SIMATIC WinCC and WinCC flexible HMI software, making it directly compatible with Siemens S7 PLC families via Ethernet or MPI/PROFIBUS adapters.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AE10-0BE0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout with the supplied seal.

    Can the storage medium on the Panel PC 670 be replaced or upgraded?

    The SIMATIC Panel PC 670 uses a replaceable hard disk drive or CompactFlash card as its primary storage medium, which can be replaced or upgraded. Siemens recommends using approved storage devices to ensure compatibility and reliability.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power input connector to confirm it is within the specified tolerance. Check for a blown internal fuse on the power supply board.

    Ensure the 24 V DC supply is stable and within tolerance. Replace the internal fuse if blown. If the power supply board is faulty, replace the internal power supply module.

    Display is blank but the system appears to be running (LEDs active, fan spinning)

    Check the display backlight by shining a torch at the screen to see if a faint image is visible. Inspect the display cable connection between the mainboard and the LCD panel.

    If the backlight is failed, replace the CCFL backlight or the entire LCD assembly. If the display cable is loose or damaged, reseat or replace it. A failed display controller on the mainboard may require board-level repair.

    Touchscreen input is inaccurate or unresponsive

    Attempt to recalibrate the touchscreen using the Windows calibration utility. Check for physical damage or contamination on the touch surface. Inspect the USB or serial connection of the touch controller.

    Perform a full touchscreen recalibration. Clean the touch surface with a soft cloth. If the touch controller connection is loose, reseat it. Replace the touchscreen assembly if hardware damage is confirmed.

    System freezes or reboots unexpectedly during operation

    Check internal temperature using the BIOS or system monitoring utility to rule out thermal shutdown. Review Windows Event Viewer logs for application errors or watchdog events. Test the RAM modules if accessible.

    Ensure adequate ventilation and clean any dust from internal components. Update or reinstall the HMI application. If RAM is faulty, replace with a compatible module. Restore the OS image if software corruption is suspected.

    Ethernet communication with PLC is lost intermittently

    Check the Ethernet cable for damage and verify the connection at both the Panel PC and the network switch. Use the ping command to test network continuity. Review IP address and subnet configuration in Windows network settings.

    Replace the Ethernet cable if damaged. Assign a static IP address to avoid DHCP-related connectivity drops. Update the network adapter driver if available. If the onboard Ethernet port is faulty, use a USB-to-Ethernet adapter as a temporary measure.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart