• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB32-0AE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB32-0AE0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB32-0AE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB32-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface applications, combining computing power with a rugged, integrated display unit. This product serves as a full-featured industrial PC in a compact panel-mount form factor, suitable for use directly on the machine or in a control cabinet door.

    The SIMATIC Panel PC 670 (6AV7612-0AB32-0AE0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and integrates a touch screen interface for operator interaction. It is based on an x86-compatible processor architecture and supports standard PC operating systems such as Windows XP Professional or Windows XP Embedded. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), enabling integration with a wide range of automation and peripheral devices. It is designed to meet industrial environmental requirements with an IP65-rated front panel for protection against dust and water ingress.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI solution is required. Its panel-mount design makes it suitable for integration into control panels in industries such as automotive, food and beverage, pharmaceuticals, and general machine building. The combination of standard PC functionality with industrial-grade hardware makes it appropriate for SCADA visualization, data logging, and complex HMI applications that require more processing capability than a standard operator panel.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 60 W
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), USB 2.0, RS-232 (COM ports)
    Operating System Windows XP Professional / Windows XP Embedded
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence.
    Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty.
    Event ID: 200
    Fan failure detected. Cooling fan is not operating within specified speed range.
    Check fan connector and clean any dust blockage. Replace the internal cooling fan if it does not spin up on power-on.
    Event ID: 300
    Watchdog timeout triggered. The application or operating system did not respond within the watchdog interval.
    Investigate application software for hangs or deadlocks. Increase watchdog timeout interval in BIOS or software configuration if appropriate.
    Event ID: 400
    Battery low warning. The CMOS/RTC backup battery voltage is below threshold.
    Replace the internal CMOS lithium battery (CR2032 or equivalent). After replacement, re-enter BIOS settings and verify system time and date.
    Event ID: 500
    Ethernet communication fault. Network interface is not detecting a valid link.
    Check Ethernet cable and switch port. Verify network adapter settings in Device Manager. Replace cable or network switch port if physical layer fault is confirmed.
    Event ID: 600
    Touchscreen calibration error. Touch input coordinates are misaligned with display output.
    Run the touchscreen calibration utility from the Windows control panel or Siemens panel configuration tool. Recalibrate using a stylus for accuracy.
    Event ID: 700
    Temperature warning. Internal temperature sensor has exceeded the upper warning threshold.
    Check ambient temperature around the panel. Ensure ventilation clearances are maintained. Clean air filters and verify cooling fan operation.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AB32-0AE0?

    The SIMATIC Panel PC 670 (6AV7612-0AB32-0AE0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.

    What operating system does this Panel PC support?

    This unit supports Windows XP Professional and Windows XP Embedded. It is based on an x86-compatible architecture, allowing standard PC software to be installed.

    What is the IP protection rating of the front panel?

    The front panel of the 6AV7612-0AB32-0AE0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets.

    What communication interfaces are available on this unit?

    The Panel PC 670 provides Ethernet (RJ45), USB 2.0 ports, and RS-232 serial interfaces, enabling connectivity to PLCs, networks, and peripheral devices.

    Can this Panel PC be used with Siemens WinCC SCADA software?

    Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and WinCC flexible visualization software, making it suitable for SCADA and advanced HMI applications.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector. Verify that the supply is within tolerance and that the power LED indicator is active. Measure voltage at the internal power supply output rails.

    Ensure the 24 V DC supply is stable and correctly connected. If the internal power supply has failed, replace the power supply module. If the display backlight has failed, replace the backlight inverter or the display assembly.

    Touchscreen does not respond or registers incorrect touch positions

    Verify that the touchscreen driver is correctly installed in Device Manager. Check for physical damage or contamination on the touch surface. Attempt a touchscreen recalibration.

    Run the touchscreen calibration utility in the Windows control panel. If the touchscreen controller is unresponsive, check the internal ribbon cable connection between the touch panel and the controller board. Replace the touch panel assembly if the hardware is faulty.

    Panel PC fails to boot or continuously restarts

    Connect an external monitor via the VGA port to determine if the issue is display-related or a true boot failure. Check the CompactFlash card or hard disk for errors using a bootable diagnostic tool.

    Replace the CompactFlash card or hard disk with a new unit and restore the operating system image. If the issue persists, check the RAM modules for seating and integrity. Replace faulty memory if identified.

    Ethernet communication is not established

    Check the RJ45 connector and cable for physical damage. Verify the link LED on the Ethernet port is active. Open Device Manager to confirm the network adapter is recognized and no driver errors are present.

    Replace the Ethernet cable and verify the connected switch port is active. Reinstall the network adapter driver if it shows an error in Device Manager. If the onboard NIC has failed, replace the main board or use a USB-to-Ethernet adapter as a temporary measure.

    System time and date reset after each power cycle

    This indicates the CMOS backup battery has discharged. Enter the BIOS setup on next boot to confirm that the date and time are not retained between power cycles.

    Replace the internal CMOS lithium battery (typically CR2032). After replacement, re-enter the correct date, time, and BIOS settings, then save and exit the BIOS setup.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart