Siemens 6AV7612-0AB22-0BG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB22-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling both operator control and data processing within a single device.
The SIMATIC Panel PC 670 6AV7612-0AB22-0BG0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology. It is powered by an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB, serial (COM), parallel, and Ethernet ports, and is built to meet industrial requirements with a fanless or low-noise cooling design and a front panel rated to IP65 for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, panel-integrated PC with visualization capabilities is required. Its compatibility with Siemens SIMATIC software and standard PC peripherals makes it suitable for integration into existing SIMATIC automation architectures. Typical applications include production line monitoring, process visualization, and machine control panels in automotive, chemical, and food and beverage industries.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive Touch Screen |
| Front Panel Protection Rating | IP65 |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM), Parallel Port |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Mounting | Panel Mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout triggered, indicating the application or OS has become unresponsive.
Restart the Panel PC. Check for software conflicts or excessive CPU load. Update or reinstall the HMI application. - Event ID: 300
- Fan failure or thermal warning detected, indicating the cooling system is not functioning correctly.
Inspect and clean ventilation openings. Check fan operation. Ensure ambient temperature is within specified operating range. - Event ID: 400
- Ethernet communication failure or network interface not detected.
Check Ethernet cable and network switch connection. Verify IP address configuration in the operating system. Replace Ethernet cable or check NIC driver. - Event ID: 500
- Touch screen calibration error or touch input not responding correctly.
Recalibrate the touch screen using the Windows control panel or SIMATIC calibration utility. Clean the touch surface. Replace touch screen controller if recalibration fails. - Event ID: 600
- Power supply undervoltage detected on the 24 V DC input.
Measure the 24 V DC supply voltage at the power connector. Ensure supply is within tolerance (20.4–28.8 V DC). Replace or adjust the external power supply unit. - Event ID: 700
- CompactFlash or hard disk read/write error detected.
Check storage media seating and connector. Run disk diagnostics. Replace CompactFlash card or hard disk drive if errors persist.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AB22-0BG0?
The SIMATIC Panel PC 670 6AV7612-0AB22-0BG0 operates on a 24 V DC supply voltage, typically within a tolerance range of 20.4 V DC to 28.8 V DC.
What operating system does this Panel PC support?
This unit supports Microsoft Windows XP Professional and Windows 2000, and is compatible with Siemens SIMATIC WinCC and other standard HMI/SCADA software packages.
What is the front panel protection rating of this device?
The front panel of the 6AV7612-0AB22-0BG0 is rated to IP65, providing protection against dust ingress and low-pressure water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, RS-232 serial (COM) ports, and a parallel port for peripheral and network connectivity.
Is the display on this Panel PC a touch screen?
Yes, the 12.1-inch SVGA display uses resistive touch screen technology, allowing operator input directly on the screen surface.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector. Check for blown fuses or wiring faults in the supply circuit.
Ensure the supply voltage is within the 20.4–28.8 V DC range. Replace any blown fuses and verify wiring integrity. If the internal power supply board is faulty, replace it.
Display is blank or shows no image after power on
Check if the PC is booting by listening for disk activity or connecting an external monitor via the VGA port if available. Verify backlight operation.
If the PC boots but the display is blank, the backlight inverter or CCFL backlight may have failed. Replace the backlight inverter board or the display assembly. If no boot activity is detected, diagnose the mainboard or storage media.
Touch screen does not respond or registers incorrect input positions
Attempt to recalibrate the touch screen through the Windows Control Panel or SIMATIC calibration tool. Check for physical damage or contamination on the screen surface.
Clean the touch surface with a soft, dry cloth. Recalibrate using the system utility. If the issue persists, replace the touch screen controller card or the touch overlay assembly.
System freezes or reboots unexpectedly during operation
Check CPU temperature and ventilation. Review Windows Event Viewer logs for application or system errors. Monitor for watchdog timeout events.
Clean ventilation openings and ensure ambient temperature is within specification. Update or reinstall the HMI application. If hardware faults are logged, check RAM seating and replace storage media if disk errors are present.
Ethernet communication is lost or the network interface is not recognized
Check the Ethernet cable and switch port. Verify the IP address and network settings within the Windows operating system. Check Device Manager for NIC driver errors.
Replace the Ethernet cable and verify switch port operation. Reinstall the network adapter driver. If the NIC is faulty, replace the mainboard or use a USB-to-Ethernet adapter as a temporary measure.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page