Siemens 6AV7612-0AB22-0BF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB22-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, providing a compact all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AB22-0BF0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors, offering clear visualization of process data. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP Professional or Windows 2000, supporting standard industrial software environments. The unit provides multiple communication interfaces including Ethernet (RJ45), serial ports (RS-232), USB ports, and a PS/2 interface, enabling integration with a wide range of automation and peripheral devices. It supports PROFIBUS connectivity via optional expansion and is built to withstand industrial environments with an IP65-rated front panel.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a robust, panel-mounted PC-based HMI solution is required. It is suitable for applications such as SCADA visualization, recipe management, data logging, and supervisory control in industries including automotive, food and beverage, chemical processing, and packaging. Its fanless or low-noise design options and industrial-grade construction make it appropriate for continuous operation in production environments.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 64,000 colors |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB, PS/2 |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the integrity of the OS installation. Verify the hard disk or CompactFlash card is properly seated and functional. Reinstall the OS if necessary. - Event ID: 1001
- Application crash or unexpected software termination detected by Windows error reporting.
Review the Windows event log for details. Update or reinstall the affected application. Check for memory or hardware faults. - Event ID: 7026
- A boot-start or system-start driver failed to load during Windows startup.
Check Device Manager for driver errors. Reinstall or update the relevant hardware driver. Verify hardware compatibility with the installed OS version. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or automation controller.
Check Ethernet or PROFIBUS cable connections. Verify IP address configuration and network settings. Confirm the PLC is powered and communicating on the network. - Hard Disk Fault
- The internal hard disk or storage medium is reporting errors or is not detected.
Check the hard disk connection and seating. Run a disk diagnostic utility. Replace the hard disk or CompactFlash card if faulty and restore the system image. - Watchdog Timeout
- The system watchdog timer has triggered, indicating the CPU or application has stopped responding.
Restart the Panel PC. Check for software loops or resource overloads. Verify that the application software is functioning correctly and not exceeding CPU or memory limits. - Power Supply Fault
- The 24 V DC supply voltage is out of tolerance or has been interrupted.
Measure the supply voltage at the power connector. Ensure the supply is within the specified 24 V DC range. Check wiring, fuses, and the external power supply unit.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7612-0AB22-0BF0?
The unit operates on a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range for reliable operation.
What display size and resolution does this Panel PC have?
The 6AV7612-0AB22-0BF0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors.
What operating system does the SIMATIC Panel PC 670 support?
This unit supports Microsoft Windows XP Professional and Windows 2000, which are compatible with standard SIMATIC WinCC and other Siemens HMI software packages.
What communication interfaces are available on this unit?
The panel provides Ethernet (RJ45), RS-232 serial ports, USB ports, and PS/2 interfaces as standard. PROFIBUS connectivity can be added via optional expansion cards.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7612-0AB22-0BF0 is rated IP65, making it resistant to dust and water jets, suitable for panel-mounting in industrial environments.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the backlight is functioning by shining a light at the screen to check for a faint image. Inspect internal fuse and power supply board.
Restore the 24 V DC supply if out of range. Replace the backlight inverter or LCD panel if the backlight has failed. Replace the internal power supply module if no voltage is present internally.
Panel PC fails to boot or gets stuck at startup screen
Check the hard disk or CompactFlash storage for errors using a diagnostic tool. Verify that the OS installation is intact. Check for any recently installed software or drivers that may be causing conflicts.
Reseat or replace the hard disk or CompactFlash card. Reinstall the operating system and SIMATIC software from a known-good backup image. Remove any recently added software causing boot failure.
Touchscreen does not respond or is inaccurate
Check if the touchscreen controller is recognized in Device Manager. Verify that the touchscreen calibration has not been corrupted. Inspect the touchscreen connector cable for damage or loose connection.
Recalibrate the touchscreen using the Windows control panel or SIMATIC calibration utility. Reseat the touchscreen ribbon cable. Replace the touchscreen overlay if physical damage is present.
Loss of communication with PLC or network devices
Verify Ethernet cable connections and check the network switch or hub. Confirm the IP address settings on the Panel PC match the network configuration. Check for firewall or software settings blocking communication.
Correct the IP address and subnet mask configuration. Replace the Ethernet cable if faulty. Reinstall the network adapter driver or replace the network interface card if the hardware is defective.
System runs slowly or application performance is degraded
Check CPU and memory utilization in Windows Task Manager. Identify any background processes consuming excessive resources. Check the hard disk for fragmentation or errors.
Close unnecessary background applications and disable non-essential startup programs. Run a disk defragmentation and error check. If the hard disk is failing, replace it and restore the system image.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page