Siemens 6AV7612-0AB20-0CJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB20-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface applications, combining a built-in display with a full PC architecture running Windows-based operating systems. This unit integrates computing power and visualization into a single compact front-panel device suitable for cabinet or console mounting.
The SIMATIC Panel PC 670 (6AV7612-0AB20-0CJ0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology. It is based on an Intel Celeron processor platform and supports standard PC interfaces including USB, serial (COM), parallel, and Ethernet ports for connectivity to controllers and peripheral devices. The unit is designed for 24 V DC supply input and is built to IEC 61131-2 environmental standards, with a fanless or low-noise cooling design suited for continuous industrial operation.
The SIMATIC Panel PC 670 is widely deployed in manufacturing automation, process control, and machine tool applications where a full Windows PC environment is required at the operator station. It is commonly used in automotive assembly lines, packaging machinery, and chemical processing plants where operators need rich graphical interfaces, data logging, and the ability to run SCADA or WinCC visualization software directly on the panel. Its rugged construction and industrial-grade components make it suitable for environments with vibration, dust, and temperature variation.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive Touch Screen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interfaces | Ethernet (RJ45), USB, RS-232 (COM), Parallel |
| Operating System | Windows XP / Windows 2000 (factory configurable) |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup failure — the operating system failed to initialize correctly during boot.
Check hard disk or CompactFlash integrity. Verify OS installation. Re-image the storage medium if necessary. - Event ID: 1000
- Application error — a user-space application (e.g. WinCC) has crashed or become unresponsive.
Restart the application. Check event logs in Windows for details. Update or reinstall the affected software if the issue persists. - Event ID: 7026
- Boot-start or system-start driver failed to load during Windows startup.
Check Device Manager for driver conflicts. Reinstall or update the relevant hardware driver. Verify hardware connections. - BIOS POST Error
- Power-On Self-Test failure detected during startup, indicating a hardware fault.
Reseat RAM modules and expansion cards. Check battery voltage on the motherboard. Replace faulty hardware components as indicated by POST beep codes. - Watchdog Timeout
- The hardware watchdog timer has triggered a system reset due to an application or OS hang.
Investigate the application causing the hang. Adjust watchdog timeout settings in the BIOS or system configuration. Ensure adequate CPU and memory resources. - Temperature Warning
- Internal system temperature has exceeded the defined threshold, risking thermal shutdown.
Check ventilation around the panel. Clean air filters and cooling vents. Verify ambient temperature is within the 0–45 °C operating range. - Hard Disk Failure
- The internal hard disk or storage medium has reported read/write errors or is not detected.
Replace the hard disk or CompactFlash card. Re-image the replacement storage with the correct OS and application image. Verify BIOS detects the new storage device.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7612-0AB20-0CJ0) support?
The Panel PC 670 supports Windows 2000 and Windows XP, which can be factory pre-installed. The specific OS version depends on the order configuration at the time of manufacture.
What is the supply voltage for this panel PC?
The 6AV7612-0AB20-0CJ0 operates on a 24 V DC supply voltage, which is standard for SIMATIC industrial panel devices.
Is this panel PC compatible with Siemens WinCC visualization software?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SCADA or HMI software packages that are compatible with its Windows operating system environment.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AB20-0CJ0 carries an IP65 protection rating, making it resistant to dust ingress and water jets when correctly installed in a panel cutout.
Can the storage medium be replaced or upgraded?
Yes, the Panel PC 670 uses a replaceable hard disk or CompactFlash storage medium. Replacement drives must be re-imaged with the appropriate OS and application software before use.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the power LED status. Measure voltage at the internal power supply output rails.
Ensure the 24 V DC supply is within tolerance. Replace the internal power supply if voltage rails are absent. If supply is correct, the display backlight inverter or TFT panel may require replacement.
Touch screen does not respond or registers incorrect touch positions
Check the touch screen calibration settings in the Windows control panel. Inspect the touch screen overlay for physical damage or contamination.
Recalibrate the touch screen using the Windows touch screen calibration utility. Clean the screen surface. If calibration fails repeatedly, replace the resistive touch screen overlay.
System fails to boot or continuously restarts
Attempt to boot into Windows Safe Mode. Check the hard disk or CompactFlash card for errors using disk diagnostic tools. Review BIOS POST messages for hardware faults.
Run a disk check and repair corrupted OS files. If the storage medium has failed, replace it and re-image with the correct OS and application software. Check RAM modules for faults.
Ethernet communication not established with PLC or network
Verify the Ethernet cable and switch port. Check the IP address configuration in Windows Network Settings. Ping the target PLC or device from the panel PC.
Correct the IP address, subnet mask, and gateway settings. Replace the Ethernet cable if faulty. Update the network adapter driver if the interface is not recognized in Device Manager.
System overheating or unexpected thermal shutdown
Check ambient temperature around the panel installation. Inspect ventilation slots and any air filters for blockage. Monitor CPU temperature via BIOS or system monitoring tools.
Improve airflow around the panel enclosure. Clean blocked ventilation slots. Ensure ambient temperature does not exceed 45 °C. If the issue persists, check the internal cooling fan (if fitted) and replace if defective.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page