• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB12-0CH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB12-0CH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB12-0CH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB12-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, offering a compact and integrated solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7612-0AB12-0CH0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch-sensitive screen for operator interaction. It runs on a standard x86-compatible processor platform and supports Microsoft Windows operating systems, enabling compatibility with SIMATIC WinCC and other SCADA software packages. The unit provides multiple communication interfaces including Ethernet (RJ45) and standard PC ports (USB, serial), and is built to meet industrial environmental requirements including vibration and EMC standards.

    This Panel PC is widely used in manufacturing, process automation, and machine tool industries where a robust, integrated PC-based HMI solution is required. Its fanless or low-maintenance design options make it suitable for continuous operation in environments where reliability and uptime are critical. The SIMATIC Panel PC 670 is commonly deployed in automotive production lines, chemical processing plants, and packaging machinery where advanced visualization and data logging capabilities are needed alongside real-time control.

    Technical Specifications

    Display Size 12 inch
    Display Type TFT LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), USB, RS-232
    Operating System Windows XP / Windows 2000
    Series/Product Family SIMATIC Panel PC 670
    Mounting Panel mounting
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 1000
    Application error in the operating system or HMI runtime software has caused an unexpected termination.
    Check Windows Event Viewer for details. Reinstall or repair the HMI runtime software (e.g. WinCC flexible). Verify software version compatibility.
    Event ID: 6008
    The system was shut down unexpectedly, indicating a previous crash or power loss event.
    Check power supply stability and ensure 24 V DC supply is within tolerance. Inspect for hardware faults and review event logs for preceding errors.
    Hardware Error: POST Failure
    Power-On Self-Test failure detected during boot, indicating a hardware component fault.
    Reseat RAM modules and check all internal connections. If fault persists, identify the failing component via BIOS POST codes and replace the defective hardware.
    No Boot Device Found
    The Panel PC cannot locate a bootable operating system, typically due to a failed or missing storage medium (CompactFlash or hard disk).
    Check that the CompactFlash card or hard disk is properly seated. Replace the storage medium and restore the operating system image if the device has failed.
    Communication Error: Ethernet
    Loss of Ethernet communication between the Panel PC and the PLC or network, causing the HMI runtime to report a connection fault.
    Verify Ethernet cable integrity and connections. Check IP address configuration and ensure the PLC or server is reachable. Restart the communication driver if necessary.
    Touchscreen Calibration Error
    The touchscreen input is misaligned or unresponsive, causing incorrect or no touch registration.
    Run the touchscreen calibration utility from the Windows Control Panel or SIMATIC settings. If calibration fails, check the touchscreen controller connection or replace the touchscreen assembly.
    Runtime Startup Error
    WinCC flexible or SIMATIC HMI runtime fails to start or displays a startup error message.
    Verify the project file integrity and ensure the correct runtime version is installed. Check available disk space and system resources. Reload the project from the engineering station if the project file is corrupted.

    Frequently Asked Questions

    What operating systems are supported by the SIMATIC Panel PC 670 (6AV7612-0AB12-0CH0)?

    The SIMATIC Panel PC 670 supports Windows XP Professional and Windows 2000, which are compatible with SIMATIC WinCC and WinCC flexible HMI runtime software.

    What HMI software is compatible with this Panel PC?

    This unit is compatible with Siemens SIMATIC WinCC and WinCC flexible runtime software. It can also run third-party SCADA and visualization applications compatible with the Windows operating system.

    What is the supply voltage for the 6AV7612-0AB12-0CH0?

    The Panel PC 670 operates on a 24 V DC supply voltage, which is standard for SIMATIC industrial panel devices.

    What is the front panel protection rating of this Panel PC?

    The front panel of the SIMATIC Panel PC 670 is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial environments.

    Can the storage medium (CompactFlash or hard disk) be replaced in the field?

    Yes, the storage medium in the SIMATIC Panel PC 670 can typically be replaced in the field. It is recommended to create a backup image of the original storage medium before replacement to allow restoration of the operating system and project data.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power input connector. Verify that the power LED indicator is active. Measure voltage at the internal power supply output to the display backlight.

    Ensure the 24 V DC supply is within the specified tolerance. If the backlight is faulty, replace the inverter board or the display assembly. If no power LED is present, inspect the internal fuse and power supply module.

    Touchscreen does not respond or registers incorrect touch positions

    Attempt to recalibrate the touchscreen using the Windows Control Panel calibration tool. Check the touchscreen controller cable connection inside the unit.

    Perform a full touchscreen recalibration. If the issue persists after calibration, reseat the touchscreen controller cable. If the touchscreen remains unresponsive, replace the touchscreen overlay or the touchscreen controller board.

    Panel PC fails to boot and displays 'No Boot Device' or similar message

    Enter the BIOS setup to verify that the CompactFlash card or hard disk is detected. Check that the storage medium is properly seated in its slot or connector.

    Reseat the CompactFlash card or hard disk. If the device is not detected after reseating, replace the storage medium. Restore the operating system and HMI project using a backup image.

    HMI runtime software crashes repeatedly or fails to start

    Review the Windows Event Viewer application log for error codes and timestamps. Check available disk space and verify the integrity of the project file stored on the device.

    Free up disk space if necessary and reload the HMI project from the engineering station. Reinstall the WinCC flexible runtime if the software installation is corrupted. Ensure the runtime version matches the project version.

    Ethernet communication to PLC is lost intermittently

    Check the Ethernet cable and RJ45 connector for physical damage. Verify the IP address settings in Windows Network Connections and confirm the PLC IP address is correctly configured in the HMI project.

    Replace the Ethernet cable if damaged. Assign a static IP address to avoid DHCP-related connectivity issues. Restart the HMI communication driver or reboot the Panel PC to re-establish the connection.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart