Siemens 6AV7612-0AB10-0BJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB10-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside process control applications.
The SIMATIC Panel PC 670 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and integrates a touch-sensitive screen for operator interaction. It is built around an industrial-grade processor platform and supports communication via standard interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232). The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress from the operator side. It operates on a 24 V DC supply and is built to withstand the vibration and temperature variations typical of industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, chemical processing, and packaging. Its PC-based architecture allows it to run Siemens WinCC, WinCC flexible, and third-party SCADA software, making it suitable for complex visualization tasks requiring high graphical performance and data logging. The front IP65 rating and robust enclosure make it appropriate for installation in control cabinets and machine panels exposed to harsh shop-floor conditions.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Communication Interface | Ethernet (RJ45), USB, RS-232 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Front panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the hard disk or CompactFlash card for errors. Verify the OS installation is intact and reboot the device. Replace storage media if corrupted. - Event ID: 200
- Hardware watchdog timeout — the watchdog timer triggered due to system hang or unresponsive application.
Identify and close the application causing the hang. Check CPU load and memory usage. Update or reinstall the HMI runtime software if the issue persists. - Event ID: 300
- Fan failure detected — the internal cooling fan has stopped or is operating below the required speed.
Inspect and clean the fan. Replace the fan unit if it is defective to prevent thermal shutdown. - Event ID: 400
- Temperature warning — internal temperature has exceeded the defined threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters and verify fan operation. Reduce ambient temperature if possible. - Event ID: 500
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC output within specified tolerances. - Event ID: 600
- Communication loss — Ethernet or serial communication with the connected PLC or controller has been interrupted.
Check network cables and connectors. Verify IP address configuration and network switch status. Restart the communication driver or HMI runtime application. - Event ID: 700
- Touchscreen calibration error — the touch input is misaligned or unresponsive.
Run the touchscreen calibration utility from the Windows Control Panel or SIMATIC settings. If calibration fails, check the touchscreen controller connection internally.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7612-0AB10-0BJ0) run?
The SIMATIC Panel PC 670 is designed to run Microsoft Windows XP Embedded or Windows 2000, depending on the specific configuration ordered. This allows it to execute standard Windows-based HMI and SCADA software.
What HMI software is compatible with this Panel PC?
The unit is compatible with Siemens WinCC, WinCC flexible, and ProTool runtime software. It can also run third-party SCADA and visualization applications that are compatible with the installed Windows operating system.
What is the display size and resolution of the 6AV7612-0AB10-0BJ0?
This Panel PC features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
What is the supply voltage for this Panel PC?
The 6AV7612-0AB10-0BJ0 operates on a 24 V DC power supply.
What is the IP protection rating of this Panel PC?
The front face of the SIMATIC Panel PC 670 carries an IP65 protection rating, providing protection against dust and water jets from the operator side. The rear of the unit is not rated to IP65.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power supply connector. Verify the display backlight is functioning by shining a light at the screen to check for faint images.
If voltage is present but display is blank, the backlight inverter or CCFL lamp may have failed. Replace the backlight inverter board or the display assembly. If no voltage is present, check the power supply unit and wiring.
Touchscreen does not respond or responds inaccurately
Attempt to operate the unit using a connected USB mouse or keyboard to determine if the issue is isolated to the touchscreen. Check Device Manager in Windows for touchscreen controller errors.
Run the touchscreen calibration utility. If calibration does not resolve the issue, check the internal ribbon cable connection between the touchscreen overlay and the controller board. Replace the touchscreen overlay if damaged.
Panel PC fails to boot or hangs at startup
Observe the boot sequence for error messages. Check the hard disk or CompactFlash storage media for errors using a diagnostic tool. Verify that the BIOS settings are correct.
Run a disk check utility (chkdsk) on the storage media. If the OS is corrupted, reinstall the operating system and HMI runtime software. Replace the storage media if hardware failure is detected.
Ethernet communication not established with PLC
Check the Ethernet cable and connector for physical damage. Verify the IP address configuration in Windows Network Settings matches the required network subnet. Ping the PLC from the Panel PC to test connectivity.
Replace the Ethernet cable if damaged. Correct the IP address, subnet mask, and gateway settings. Check the network switch or hub. Reinstall the network adapter driver if the adapter is not recognized in Device Manager.
Unit shuts down unexpectedly or displays temperature warning
Check the ambient temperature around the Panel PC installation. Inspect the internal fan for operation and listen for unusual noise. Check that ventilation slots are not blocked.
Ensure the installation environment is within the 0 °C to 45 °C operating range. Clean dust from ventilation slots and the internal fan. Replace the fan if it is not spinning. Ensure the control cabinet has adequate cooling.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page