• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB10-0BH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB10-0BH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB10-0BH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB10-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7612-0AB10-0BH0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology. It is powered by an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB ports, serial COM ports, and an Ethernet interface for network connectivity, along with a CompactFlash slot for additional storage. The enclosure is rated IP65 on the front panel, protecting against dust and water ingress in industrial environments.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a full PC-based HMI platform is required. Its fanless or low-maintenance design options make it suitable for continuous operation in production lines, packaging machinery, and plant visualization systems. The combination of standard PC architecture with industrial-grade construction allows integration with a broad range of automation software and communication networks.

    Technical Specifications

    Display Size 12.1 inch
    Display Type TFT Color LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Touch Technology Resistive Touch Screen
    Input Voltage 24 V DC
    Power Consumption Approx. 60 W
    Front Panel Protection IP65
    Rear Protection IP20
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232 COM ports
    Storage CompactFlash slot, Hard Disk Drive
    Mounting Panel mounting
    Certifications CE, UL
    Series SIMATIC Panel PC 670

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup error or boot failure detected during POST.
    Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty.
    Event ID: 101
    Hardware watchdog timeout — the system did not respond within the watchdog monitoring period.
    Check CPU load and running processes. Restart the Panel PC and verify that the HMI application is not causing system overload.
    Event ID: 200
    Fan failure detected (if fan-cooled variant). Cooling system not operating correctly.
    Inspect and clean the fan unit. Replace the fan if it is not spinning. Ensure ventilation clearances around the unit are maintained.
    Event ID: 201
    Overtemperature warning — internal temperature has exceeded the permissible operating limit.
    Check ambient temperature and ensure it is within 0–45 °C. Clean air vents and verify fan operation. Reduce heat load in the control cabinet.
    Event ID: 300
    Ethernet communication error — network connection lost or interface not recognized.
    Check Ethernet cable and connector integrity. Verify network switch port status. Reinstall network adapter drivers if the interface is not recognized by the OS.
    Event ID: 400
    HMI runtime application fault — WinCC or SCADA software has crashed or failed to start.
    Restart the HMI application. Check application logs for specific error details. Reinstall the runtime software if the issue persists.
    Event ID: 500
    Battery low warning — CMOS/RTC backup battery voltage is below threshold.
    Replace the internal CMOS backup battery (typically CR2032 or equivalent). After replacement, reconfigure BIOS date/time settings.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AB10-0BH0?

    The SIMATIC Panel PC 670 (6AV7612-0AB10-0BH0) operates on a 24 V DC supply voltage, which is standard for industrial panel PCs in this series.

    What operating system does this Panel PC support?

    The 6AV7612-0AB10-0BH0 supports Microsoft Windows operating systems, typically Windows XP Professional or Windows 2000, and is compatible with SIMATIC WinCC and other Siemens HMI software packages.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AB10-0BH0 is rated IP65, providing full protection against dust ingress and protection against low-pressure water jets.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), USB ports, and RS-232 serial COM ports, enabling connectivity to PLCs, networks, and peripheral devices.

    Is the touch screen on the 6AV7612-0AB10-0BH0 resistive or capacitive?

    The touch screen on this unit uses resistive touch technology, which is suitable for use with gloves or stylus in industrial environments.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector. Verify that the internal power supply is functioning and that the backlight inverter is operational.

    Ensure the 24 V DC supply is within tolerance. If the backlight is faulty, replace the backlight inverter or the display assembly. Check internal fuses if no power LED is illuminated.

    Touch screen does not respond or is inaccurate

    Determine whether the issue is a hardware fault or a calibration problem. Test touch response in the operating system's touch calibration utility.

    Recalibrate the touch screen using the Windows control panel or Siemens calibration tool. If the touch screen remains unresponsive, inspect the touch controller ribbon cable connection and replace the touch screen overlay if damaged.

    Panel PC fails to boot or repeatedly restarts

    Check the hard disk or CompactFlash card for errors using a diagnostic tool. Verify BIOS settings and check for POST error messages on screen.

    Run a disk check utility to repair file system errors. If the storage device is faulty, replace the hard disk or CompactFlash card and reinstall the operating system and HMI software.

    Ethernet communication is not established

    Verify the Ethernet cable is properly connected and the network switch port is active. Check Device Manager in Windows for any network adapter errors or missing drivers.

    Replace the Ethernet cable if damaged. Reinstall or update the network adapter driver. If the onboard Ethernet port is defective, use a USB-to-Ethernet adapter as a temporary measure and arrange for board-level repair.

    System clock loses time after power off

    The CMOS backup battery is likely discharged. This is indicated if the system time resets to a default date each time the unit is powered on.

    Replace the internal CMOS/RTC backup battery with the correct type (typically CR2032). After replacement, set the correct date and time in the BIOS and verify that the operating system clock synchronizes correctly.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart