• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA32-0BF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA32-0BF0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AA32-0BF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA32-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7612-0AA32-0BF0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is powered by an Intel Celeron processor and runs Microsoft Windows XP Professional or Windows XP Embedded, providing a familiar PC environment for SCADA and HMI software deployment. The unit includes standard PC interfaces such as USB, Ethernet (RJ45), serial COM ports, and a PCI expansion slot, enabling flexible integration with automation networks and peripherals. The fanless or fan-cooled design options and industrial-grade components ensure reliable operation in harsh industrial conditions.

    The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, pharmaceutical, and chemical industries for machine-level visualization, process monitoring, and data acquisition. Its compatibility with Siemens WinCC, WinCC flexible, and third-party SCADA software makes it suitable for complex visualization applications requiring a full PC platform. The rugged construction and panel-mount design allow direct integration into control cabinet doors and operator panels on the factory floor.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Processor Intel Celeron
    Operating System Windows XP Professional / Windows XP Embedded
    Input/Operating Voltage 24 V DC
    Communication Interface Ethernet RJ45, USB, RS-232 (COM ports)
    Expansion 1 x PCI slot
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Mounting Panel mount
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
    Check the CompactFlash card or hard disk for errors. Reinstall or restore the operating system image using the Siemens recovery medium.
    Event ID: 200
    Hardware watchdog timeout — the watchdog timer has triggered a system reset due to an application or OS hang.
    Investigate the running HMI or SCADA application for software loops or deadlocks. Update or reinstall the application software and check system resource usage.
    Event ID: 300
    Temperature warning — internal system temperature has exceeded the warning threshold.
    Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters if present and verify that the cooling fan (if fitted) is operating correctly.
    Event ID: 400
    UPS battery low — the integrated UPS module reports insufficient battery charge to support a safe shutdown.
    Replace the UPS battery module. Ensure the UPS is correctly configured in the BIOS/system settings for the installed battery type.
    Event ID: 500
    Network communication failure — the Ethernet interface cannot establish or maintain a connection to the automation network.
    Check Ethernet cable connections and network switch status. Verify IP address configuration and network settings in Windows Device Manager.
    Event ID: 600
    Storage medium error — read/write errors detected on the CompactFlash card or hard disk drive.
    Run a disk check utility (chkdsk) to identify and repair file system errors. Replace the CompactFlash card or hard disk if physical errors are confirmed.
    Event ID: 700
    Display backlight failure — the LCD backlight has failed or is operating below normal brightness levels.
    Replace the backlight inverter board or the LCD display assembly. Check the backlight connector and supply voltage on the inverter board.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AA32-0BF0?

    The SIMATIC Panel PC 670 (6AV7612-0AA32-0BF0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.

    What operating system does this Panel PC run?

    This unit supports Microsoft Windows XP Professional or Windows XP Embedded as the operating system, providing a full PC environment for HMI and SCADA applications.

    Is this Panel PC compatible with Siemens WinCC software?

    Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and WinCC flexible visualization software, as well as third-party SCADA applications that support Windows XP.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AA32-0BF0 carries an IP65 protection rating, making it resistant to dust and water jets for use in industrial environments.

    Does this Panel PC support expansion cards?

    Yes, the SIMATIC Panel PC 670 includes one PCI expansion slot, allowing the installation of additional interface cards such as PROFIBUS or other fieldbus communication cards.

    Troubleshooting

    Panel PC does not boot after power on

    Check the 24 V DC supply voltage at the power connector. Verify that the CompactFlash card or hard disk is properly seated and recognized in the BIOS. Listen for POST beep codes that may indicate a hardware fault.

    Reseat the CompactFlash card or hard disk. If the storage medium is corrupted, restore the operating system using the Siemens recovery image. If the unit still does not boot, check the motherboard for visible damage or failed capacitors.

    Touch screen does not respond or is inaccurate

    Verify that the touch screen controller driver is correctly installed in Windows Device Manager. Check the touch screen ribbon cable connection between the display assembly and the motherboard.

    Recalibrate the touch screen using the Windows touch screen calibration utility. If calibration fails, reinstall the touch screen driver. Replace the touch screen overlay or controller board if hardware damage is confirmed.

    Display shows no image but the system appears to be running

    Check the LCD backlight by observing the screen in a dark environment with a flashlight to determine if the image is present but not backlit. Measure the voltage output of the backlight inverter board.

    Replace the backlight inverter board if no output voltage is detected. If the inverter is functioning but the backlight tube is faulty, replace the LCD assembly. Check the backlight enable signal from the motherboard.

    Ethernet communication is not working

    Check the Ethernet cable and RJ45 connector for physical damage. Verify the link and activity LEDs on the Ethernet port. Open Windows Device Manager to confirm the network adapter is recognized and no driver errors are present.

    Replace the Ethernet cable if damaged. Reinstall the network adapter driver if it shows an error in Device Manager. If the onboard Ethernet port is faulty, install a PCI Ethernet card in the available expansion slot as a replacement.

    System runs slowly or HMI application freezes

    Check CPU and memory usage in Windows Task Manager. Verify available disk space on the system drive. Check for background processes or antivirus software consuming excessive resources.

    Close unnecessary background applications and disable non-essential startup programs. If the CompactFlash card or hard disk is nearly full, archive old data and free up space. Consider upgrading the RAM if the system is running below the recommended memory for the installed application.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart