Siemens 6AV7612-0AA32-0AG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA32-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP or Windows XP Embedded as its operating system, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB ports, Ethernet (RJ45), serial COM ports, and a PS/2 interface, enabling flexible connectivity to PLCs and peripheral devices. The enclosure is rated to IP65 at the front panel, protecting against dust and water ingress in industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, automotive production, and machine building applications where a robust, integrated PC-based HMI solution is required. Its industrial-grade construction makes it suitable for installation in control cabinets and operator panels on the factory floor. The device is compatible with the broader Siemens SIMATIC automation ecosystem, allowing seamless integration with S7-300 and S7-400 PLCs via PROFIBUS or Industrial Ethernet.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interfaces | Ethernet (RJ45), USB, RS-232 (COM), PS/2 |
| Operating System | Windows XP / Windows XP Embedded |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the Panel PC failed to complete the boot sequence correctly.
Check power supply voltage (24 V DC), verify hard disk integrity, and inspect BIOS settings. Reload or restore the operating system image if necessary. - Event ID: 1000
- Application fault — a running HMI or SCADA application (e.g. WinCC) has crashed or encountered an unhandled exception.
Restart the application. Check Windows Event Viewer for detailed error logs. Reinstall or update the HMI software if the fault recurs. - Event ID: 7000
- Service control manager error — a required Windows service failed to start during boot.
Check Windows Event Viewer under System logs. Verify that all required services are enabled and not corrupted. Repair or reinstall the operating system if needed. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or network device.
Check Ethernet or PROFIBUS cable connections. Verify IP address configuration and network settings. Confirm PLC is powered and in RUN mode. - Hard Disk Error
- The internal hard disk or CompactFlash storage device is failing or not detected.
Check BIOS to confirm storage device is detected. Replace the hard disk or CompactFlash card and restore the system image from backup. - Watchdog Timeout
- The hardware watchdog timer has triggered, indicating the system has become unresponsive.
Perform a controlled restart. Investigate CPU load and running processes. Check for software loops or resource exhaustion in the HMI application. - Temperature Warning
- Internal system temperature has exceeded the permissible operating threshold.
Check ambient temperature around the panel. Clean ventilation openings and ensure adequate airflow. Verify that the installation environment is within the 0 °C to +50 °C operating range.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AA32-0AG0?
The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7612-0AA32-0AG0 is rated IP65, providing full protection against dust and resistance to water jets. The rear of the unit is rated IP20.
Which HMI and SCADA software is compatible with this Panel PC?
The unit is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other Windows-based HMI and SCADA packages. It runs Windows XP or Windows XP Embedded as its operating system.
Can this Panel PC communicate with Siemens S7 PLCs?
Yes, the 6AV7612-0AA32-0AG0 can communicate with S7-300 and S7-400 PLCs via Industrial Ethernet (using the onboard RJ45 port) or via PROFIBUS with an appropriate communication card.
What display size and resolution does this unit have?
The unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports resistive touch screen input.
Troubleshooting
Panel PC does not power on after applying 24 V DC supply
Measure the supply voltage at the power connector to confirm 24 V DC is present and within tolerance. Check for blown internal fuses or a faulty power supply module.
Replace any blown fuses with the correct rating. If the internal power supply module is faulty, replace it. Verify wiring polarity and cable integrity before re-applying power.
Display is blank or shows no image after power on
Check whether the system is booting by listening for hard disk activity or observing indicator LEDs. Determine if the issue is with the display backlight, the display panel itself, or the video output from the PC board.
Replace the backlight inverter or TFT display panel if the backlight has failed. If the PC board is not generating a video signal, inspect the graphics hardware or replace the main board.
Touch screen input is unresponsive or inaccurate
Verify that the touch screen controller drivers are correctly installed in Windows. Check the USB or internal touch controller connection. Attempt a touch screen recalibration via the Windows control panel.
Recalibrate the touch screen using the calibration utility in Windows. If the touch screen remains unresponsive, check the internal cable connection between the touch panel and the controller board, or replace the touch screen overlay.
System freezes or reboots unexpectedly during operation
Check Windows Event Viewer for critical errors or watchdog events. Monitor CPU temperature and system resource usage. Inspect the hard disk or CompactFlash card for errors using disk diagnostic tools.
Reduce CPU load by optimizing the HMI application. Replace a failing hard disk or CompactFlash card. Ensure the operating environment temperature is within the 0 °C to +50 °C specification. Apply all relevant Windows and driver updates.
Loss of communication with PLC or network devices
Check the Ethernet cable and RJ45 connector for physical damage. Verify the IP address, subnet mask, and gateway settings on the Panel PC. Confirm the PLC is powered and in RUN mode.
Replace damaged cables or connectors. Reconfigure network settings to match the plant network. If using a PROFIBUS card, check the bus address and cable termination resistors.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page