Siemens 6AV7612-0AA32-0AF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA32-0AF0 is an industrial Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is a high-performance, panel-mounted industrial computer designed for demanding HMI and SCADA applications requiring both visualization and computing power. This unit combines a flat-panel display with an integrated PC platform in a compact, rugged enclosure suitable for direct machine or cabinet mounting.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with an Intel Celeron or Pentium M processor depending on the specific configuration. It runs Microsoft Windows XP Professional or Windows XP Embedded as its operating system and supports communication via standard interfaces including USB, Ethernet (RJ45), serial ports (RS-232), and PS/2. The unit is designed with a fanless or low-noise cooling concept for the front panel and provides a robust aluminum front bezel with IP65 protection rating on the front face.
The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, pharmaceutical, and machine tool industries where a full PC platform is required at the operator station. Its ability to run standard Windows-based SCADA and HMI software such as WinCC makes it suitable for complex process visualization, data logging, and recipe management tasks. The integrated PC architecture allows third-party software installation, making it flexible for applications that go beyond the capabilities of standard operator panels.
Technical Specifications
| Series | SIMATIC Panel PC 670 |
|---|---|
| Display Size | 12 inch |
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 256,000 colors |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM), PS/2 |
| Operating System | Windows XP Professional / Windows XP Embedded |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cUL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Fan failure or thermal warning. Internal temperature has exceeded safe operating threshold.
Check and clean ventilation openings. Verify ambient temperature is within specification (0-45 °C). Inspect and replace cooling fan if defective. - Event ID: 300
- Hard disk or storage media read/write error detected.
Run disk diagnostics. Back up data immediately. Replace hard disk or CompactFlash card as required. - Event ID: 400
- Ethernet communication interface error or network connection lost.
Check Ethernet cable and connector integrity. Verify network switch port status. Check IP configuration in Windows Device Manager. - Event ID: 500
- USB device error or unrecognized USB peripheral connected.
Disconnect and reconnect USB device. Try an alternative USB port. Verify USB device compatibility with the installed operating system. - Event ID: 600
- WinCC Runtime communication error with PLC or controller.
Verify PLC connection parameters in WinCC project. Check Ethernet or MPI cable connections. Confirm PLC is in RUN mode and accessible on the network. - Event ID: 700
- Power supply undervoltage detected. Supply voltage has dropped below permissible 24 V DC threshold.
Measure supply voltage at the panel PC power connector. Ensure power supply unit delivers stable 24 V DC within tolerance. Check cable routing for voltage drop.
Frequently Asked Questions
What operating system does the 6AV7612-0AA32-0AF0 run?
This Panel PC 670 variant is configured to run Microsoft Windows XP Professional or Windows XP Embedded, allowing standard PC software and Siemens WinCC to be installed directly on the unit.
What is the display size and resolution of this Panel PC?
The 6AV7612-0AA32-0AF0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports up to 256,000 colors.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for industrial environments.
Is this Panel PC compatible with Siemens WinCC SCADA software?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens WinCC and WinCC flexible HMI software, and can also run third-party SCADA applications supported on Windows XP.
What communication interfaces are available on this unit?
The unit provides Ethernet (RJ45), USB ports, RS-232 serial ports, and PS/2 connectors for keyboard and mouse, enabling flexible integration into automation networks.
Troubleshooting
Display remains blank after power is applied
Check that the 24 V DC supply voltage is present and within tolerance at the power connector. Verify the power LED status on the unit. Measure voltage at the internal power supply output.
Ensure the 24 V DC supply is stable and correctly wired. If the backlight has failed, the backlight inverter or display assembly may need replacement. If no power LED is present, inspect the internal fuse and power supply module.
Touchscreen does not respond or registers incorrect touch positions
Check if the touchscreen driver is correctly installed in Windows Device Manager. Verify that the touchscreen calibration has not been corrupted. Inspect the touchscreen connector cable inside the unit.
Recalibrate the touchscreen using the Windows touchscreen calibration utility. Reinstall the touchscreen driver if it shows an error in Device Manager. If hardware damage is present, replace the touchscreen overlay.
Unit fails to boot and displays a BIOS or operating system error
Check the hard disk or CompactFlash storage device for errors using BIOS diagnostics. Verify that the storage media is correctly seated. Listen for unusual clicking sounds from the hard disk indicating mechanical failure.
Run a disk check utility from a bootable USB or CD. Restore the operating system image from a backup. Replace the hard disk or CompactFlash card if the storage device is found to be defective.
Ethernet communication to PLC or network is lost intermittently
Check the Ethernet cable and RJ45 connector for physical damage or poor contact. Verify the network switch port link LED. Check Windows Device Manager for Ethernet adapter errors or driver issues.
Replace the Ethernet cable with a known-good cable. Update or reinstall the Ethernet adapter driver. If the onboard Ethernet port is defective, use an external USB-to-Ethernet adapter as a temporary measure and arrange for board-level repair.
WinCC Runtime application crashes or freezes during operation
Check available RAM and hard disk free space in Windows. Review the Windows Event Viewer for application error logs. Verify that the WinCC project configuration matches the connected PLC type and communication settings.
Increase virtual memory allocation if RAM is insufficient. Defragment the hard disk and ensure at least 10% free disk space is maintained. Reinstall WinCC Runtime if application files are corrupted, and verify PLC communication tag configurations.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page