Siemens 6AV7612-0AA30-0AH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA30-0AH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a built-in display with a full PC architecture, enabling both operator control and data processing within a single device.
The SIMATIC Panel PC 670 (6AV7612-0AA30-0AH0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch screen interface for intuitive operator interaction. It runs on a standard x86-compatible processor architecture and supports Windows-based operating systems, allowing compatibility with standard industrial software including Siemens WinCC and other SCADA packages. The unit provides multiple communication interfaces including Ethernet and serial ports, and is built to withstand industrial conditions with a robust front panel rated to IP65 for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a combined visualization and computing platform is required. Its panel-mount design makes it suitable for integration into control cabinets and operator stations in industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. The device is particularly suited for applications requiring real-time data visualization, recipe management, and process monitoring at the machine level.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Operating System | Windows XP Embedded / Windows 2000 |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout triggered — application software has stopped responding within the defined monitoring interval.
Restart the application software. Check for software deadlocks or resource conflicts. Update or reinstall the HMI runtime software if the issue persists. - Event ID: 300
- Ethernet communication link failure — no connection established with the PLC or network.
Check Ethernet cable and connector integrity. Verify IP address configuration and network switch status. Confirm PLC communication settings match the Panel PC configuration. - Event ID: 400
- Touchscreen calibration error — touch input coordinates are misaligned or unresponsive.
Run the touchscreen calibration utility from the Windows control panel or SIMATIC configuration tool. Clean the screen surface and recalibrate. Replace the touch overlay if calibration fails repeatedly. - Event ID: 500
- Fan failure or thermal warning — internal cooling fan has stopped or CPU temperature has exceeded the warning threshold.
Inspect and clean the cooling fan and ventilation slots. Replace the internal fan if it has failed. Ensure ambient temperature is within the specified operating range. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power input connector. Ensure the power supply unit provides a stable 24 V DC output. Check wiring and connectors for voltage drop. - Event ID: 700
- Hard disk or storage media error — read/write failure detected on the internal storage device.
Run a disk diagnostic utility to check for bad sectors. Back up data immediately. Replace the hard disk drive or CompactFlash card as required.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AA30-0AH0?
The SIMATIC Panel PC 670 (6AV7612-0AA30-0AH0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.
What operating system does the 6AV7612-0AA30-0AH0 support?
This Panel PC supports Windows XP Embedded or Windows 2000, making it compatible with Siemens WinCC and other standard industrial SCADA and HMI software packages.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7612-0AA30-0AH0 is rated to IP65, providing full protection against dust ingress and protection against low-pressure water jets.
Is the 6AV7612-0AA30-0AH0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC visualization software, as it runs a Windows-based operating system and meets the hardware requirements for WinCC runtime environments.
What communication interfaces are available on this Panel PC?
The 6AV7612-0AA30-0AH0 provides Ethernet (RJ45), RS-232 serial, and USB interfaces, enabling connectivity to PLCs, network infrastructure, and peripheral devices.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power input connector. Verify that the internal power supply is functioning and that the backlight inverter board is receiving power.
Ensure the supply voltage is stable at 24 V DC. If the backlight has failed, replace the CCFL backlight or inverter board. If the display itself is faulty, replace the TFT panel assembly.
Touchscreen does not respond or responds inaccurately
Determine whether the issue is a calibration problem or a hardware failure by attempting to recalibrate via the Windows control panel. Check the touch controller connection to the motherboard.
Recalibrate the touchscreen using the SIMATIC calibration utility. If recalibration does not resolve the issue, inspect the touch overlay connector and replace the resistive touch overlay if damaged.
Panel PC fails to boot or continuously restarts
Check the storage media (hard disk or CompactFlash card) for errors using a diagnostic tool. Inspect BIOS settings and verify that the boot device is correctly configured.
Replace the hard disk or CompactFlash card if errors are detected. Reinstall the operating system and HMI software. If the issue persists, inspect the motherboard for component-level faults.
Ethernet communication with PLC is lost intermittently
Check the Ethernet cable for damage and verify the connection at both the Panel PC and the network switch. Use a network diagnostic tool to check for packet loss or IP conflicts.
Replace the Ethernet cable if damaged. Verify and correct the IP address configuration on both the Panel PC and the PLC. Update the network driver if available and check for EMC interference sources near the cable routing.
Unit overheats and shuts down unexpectedly
Check the ambient temperature around the Panel PC installation. Inspect the cooling fan for operation and verify that ventilation slots are not blocked by dust or debris.
Clean the ventilation slots and cooling fan with compressed air. Ensure the installation environment does not exceed 45 degrees C ambient temperature. Replace the internal cooling fan if it has failed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page