• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA30-0AE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA30-0AE0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AA30-0AE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA30-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit integrates computing hardware and a display into a single rugged enclosure suitable for direct panel mounting.

    The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and is equipped with a resistive touchscreen for operator input. It is powered by an Intel Celeron processor and runs Microsoft Windows XP Professional or Windows XP Embedded as its operating system. The unit provides communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling integration with PLCs and SCADA systems. It supports PROFIBUS connectivity via optional expansion and is compatible with Siemens SIMATIC WinCC and WinCC flexible visualization software.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a robust, panel-integrated PC solution is required. Its industrial-grade construction makes it suitable for use in automotive production lines, food and beverage processing, chemical plants, and packaging machinery. The combination of a standard PC architecture with industrial-hardened hardware allows operators and engineers to run complex HMI applications alongside standard PC software in harsh production environments.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 px (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Processor Intel Celeron
    Operating System Windows XP Professional / Windows XP Embedded
    Input/Operating Voltage 24 V DC
    Communication Interface Ethernet (RJ45), USB, RS-232, RS-422/RS-485
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup error or boot failure detected during POST.
    Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty.
    Event ID: 1000
    Application fault or software exception in the HMI runtime (e.g., WinCC flexible Runtime crash).
    Restart the HMI runtime application. Check application logs in Windows Event Viewer. Reinstall the runtime software if the fault persists.
    Event ID: 6008
    Windows recorded an unexpected system shutdown, indicating a previous crash or power loss.
    Check 24 V DC power supply stability. Inspect UPS if fitted. Review Windows Event Viewer for preceding error entries.
    Hardware Error: CMOS Battery
    CMOS battery voltage low, causing loss of BIOS settings and real-time clock data after power off.
    Replace the internal CMOS lithium coin cell battery (typically CR2032). Re-enter BIOS settings and synchronize system clock.
    Hardware Error: Fan Fault
    CPU or system cooling fan has failed or is running below minimum speed threshold.
    Clean fan and heatsink of dust and debris. Replace the fan unit if it does not recover. Ensure ambient temperature is within specification.
    Communication Error: Ethernet
    Loss of Ethernet network connection or failure to establish communication with PLC or SCADA server.
    Check Ethernet cable and switch/hub connections. Verify IP address configuration in Windows network settings. Test with a known-good cable.
    Hardware Error: Storage Media
    Hard disk or CompactFlash card read/write error detected by the operating system.
    Run a disk check utility (chkdsk). Back up data immediately and replace the storage medium. Restore OS and application image from backup.
    Display Error: No Signal
    Display backlight is on but no image is shown, indicating a graphics or display connection fault.
    Check internal display cable connections. Verify graphics driver installation in Windows Device Manager. Replace display cable or graphics adapter if faulty.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AA30-0AE0?

    The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.

    Which HMI software is compatible with this Panel PC?

    The 6AV7612-0AA30-0AE0 is compatible with Siemens SIMATIC WinCC and WinCC flexible visualization software, as well as other standard Windows-based SCADA and HMI applications.

    What is the front panel protection rating of this unit?

    The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for panel-mounted industrial use.

    Can the storage medium be replaced or upgraded?

    Yes, the SIMATIC Panel PC 670 supports replaceable storage media. Depending on the variant, this may be a hard disk drive or a CompactFlash card, both of which can be replaced or upgraded by a qualified technician.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), multiple USB ports, and serial interfaces (RS-232 and RS-422/RS-485), enabling connectivity to PLCs, barcode scanners, printers, and other industrial peripherals.

    Troubleshooting

    Panel PC does not boot and display remains blank after power on

    Check that the 24 V DC supply voltage is present and within tolerance at the power connector. Verify that the power LED is illuminated. Attempt to connect an external monitor to check if the fault is display-related or system-related.

    If supply voltage is correct and no output is seen on an external monitor, the internal power supply or motherboard may have failed. Reseat RAM modules and storage media. If the unit still does not boot, the motherboard or power supply module requires repair or replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Check if the touchscreen responds in Windows Device Manager. Verify that the touchscreen driver is correctly installed. Test whether the issue is present across the entire screen surface or only in specific areas.

    Recalibrate the touchscreen using the calibration utility in the Windows Control Panel or Siemens touchscreen driver software. If calibration does not resolve the issue, inspect the touchscreen controller board and cable connections. Replace the touchscreen assembly if hardware damage is confirmed.

    HMI runtime application crashes repeatedly or fails to start

    Review the Windows Event Viewer application and system logs for error codes or exception messages. Check available disk space and RAM. Verify that the WinCC flexible or WinCC runtime license is valid and correctly installed.

    Free up disk space if storage is near capacity. Reinstall the HMI runtime software if files are corrupted. Restore the OS and application from a system image backup if the installation is severely damaged.

    Ethernet communication lost with PLC or SCADA server

    Check physical Ethernet cable and switch port status LEDs. Ping the Panel PC from another device on the network. Verify IP address, subnet mask, and gateway settings in Windows network configuration.

    Replace the Ethernet cable if damaged. Reconfigure network settings if they have been altered. Update or reinstall the Ethernet adapter driver in Windows Device Manager. If the NIC hardware has failed, the motherboard or NIC module requires replacement.

    System time resets to default after every power cycle

    This symptom indicates a depleted CMOS battery. Enter the BIOS setup at startup to confirm that the date and time reset to a default value (e.g., year 2000 or 2002).

    Replace the internal CMOS coin cell battery (typically CR2032) located on the motherboard. After replacement, re-enter the correct date, time, and any modified BIOS settings, then save and exit.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart