Siemens 6AV7612-0AA22-0CE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA22-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and rugged solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AA22-0CE0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 256 colors or higher. It is equipped with standard PC interfaces including USB, serial (RS-232), parallel, and Ethernet ports, enabling integration with a wide range of automation and IT systems. The unit runs on a Windows-based operating system and supports SIMATIC WinCC and other Siemens HMI software packages. Its fanless or low-maintenance design and industrial-grade construction ensure reliable operation in harsh industrial conditions.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, automotive production, and machine tool applications where a robust, PC-based HMI platform is required. Its compatibility with Siemens SIMATIC software and standard PC peripherals makes it suitable for complex visualization tasks, data logging, and supervisory control. The panel PC format allows direct integration into control cabinet doors or operator panels, reducing installation footprint and cabling complexity.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | Ethernet (RJ45), RS-232, USB, Parallel Port |
| Operating Temperature | 0 °C to 50 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Operating System | Windows XP / Windows 2000 (embedded) |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 1000
- Application error — a running application has encountered an unexpected fault and was terminated by the operating system.
Check the Windows Event Viewer for details. Restart the application or reinstall the HMI software (e.g. WinCC flexible Runtime). - Event ID: 6008
- Unexpected shutdown — the system was shut down unexpectedly, indicating a possible power loss or system crash.
Check the 24 V DC power supply for stability and correct voltage. Inspect power connectors and UPS if installed. - BIOS POST Error
- Power-On Self-Test failure — hardware component not detected or failed during startup.
Reseat RAM modules and expansion cards. Check hard disk or CompactFlash connection. Replace faulty hardware component if fault persists. - WinCC Runtime Error
- WinCC Runtime cannot start or crashes during initialization, often due to a corrupted project or missing license.
Verify the WinCC license dongle is present and recognized. Reload or restore the HMI project from backup. Reinstall WinCC Runtime if necessary. - Network Connection Lost
- Ethernet communication to the PLC or SCADA system has been interrupted.
Check Ethernet cable and switch/hub connections. Verify IP address configuration in Windows Network Settings. Check PLC communication settings. - Hard Disk Failure Warning
- S.M.A.R.T. diagnostic indicates imminent hard disk failure or the disk is not detected at boot.
Back up all project data immediately. Replace the hard disk or CompactFlash card with a compatible replacement and restore the system image. - Touchscreen Not Responding
- The touchscreen overlay is not registering input or is miscalibrated.
Recalibrate the touchscreen using the Siemens calibration utility in the Control Panel. If unresponsive, check the internal touchscreen controller cable connection or replace the touchscreen assembly.
Frequently Asked Questions
What operating voltage does the 6AV7612-0AA22-0CE0 require?
The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
Which HMI software is compatible with this Panel PC?
The 6AV7612-0AA22-0CE0 is compatible with Siemens SIMATIC WinCC and WinCC flexible Runtime software packages, as well as other standard Windows-based HMI and SCADA applications.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for direct panel mounting in industrial environments.
Can this Panel PC communicate directly with SIMATIC S7 PLCs?
Yes, via its Ethernet interface and optional PROFIBUS or MPI communication cards, the Panel PC 670 can communicate directly with SIMATIC S7-300 and S7-400 PLCs using standard Siemens protocols.
What display size and resolution does the 6AV7612-0AA22-0CE0 have?
This unit features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA).
Troubleshooting
Display remains blank after power on
Check that the 24 V DC supply voltage is present and within tolerance at the power connector. Verify the power LED status on the unit.
Restore correct supply voltage if out of range. If voltage is correct, check the internal DC/DC converter and backlight inverter board. Replace the backlight or inverter if the backlight has failed.
Panel PC does not boot into Windows and shows BIOS screen or stops at POST
Attempt to boot and observe any POST error messages. Check whether the hard disk or CompactFlash storage device is detected in the BIOS.
Reseat or replace the hard disk/CompactFlash card. If the OS is corrupted, restore the system using a factory image or a previously created backup. Update BIOS settings if the boot order is incorrect.
Touchscreen input is inaccurate or not responding
Test touch input across the full screen surface to identify if the issue is localized or affects the entire screen. Check Device Manager in Windows for touchscreen controller errors.
Run the touchscreen calibration utility from the Siemens Control Panel applet. If calibration does not resolve the issue, inspect the internal ribbon cable connecting the touchscreen overlay to the controller board and reseat or replace as needed.
Ethernet communication to PLC is intermittent or lost
Ping the PLC from the Panel PC to check network connectivity. Inspect the Ethernet cable and switch port for link activity LEDs.
Replace the Ethernet cable if damaged. Verify and correct the IP address, subnet mask, and gateway settings in Windows. Check PLC communication configuration and ensure the correct protocol driver is installed in WinCC.
System runs slowly or HMI application freezes
Check CPU and RAM utilization in Windows Task Manager. Verify available hard disk space and check for excessive background processes or startup programs.
Close unnecessary background applications and disable non-essential startup programs. If the hard disk is nearly full, archive old log files and project backups. Consider upgrading RAM if the system is consistently at high memory utilization.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro