• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA12-0CF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA12-0CF0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AA12-0CF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA12-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface applications, combining a built-in display with a full PC architecture running Windows-based operating systems. This unit is intended for use in industrial environments where a robust, integrated computing and visualization platform is required.

    The SIMATIC Panel PC 670 (6AV7612-0AA12-0CF0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touchscreen interface for operator interaction. It is based on an Intel Celeron processor platform and supports standard PC interfaces including USB, serial (COM), and parallel ports, as well as Ethernet connectivity for integration into plant networks. The unit is designed for panel mounting and operates on a 24 V DC supply, with an IP65-rated front face providing protection against dust and water ingress in industrial settings.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC environment is needed alongside real-time visualization. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its compatibility with Siemens SIMATIC WinCC and other SCADA software packages makes it a practical choice for supervisory control and data acquisition tasks at the machine or cell level.

    Technical Specifications

    Series SIMATIC Panel PC 670
    Display Size 12.1 inch
    Display Type TFT LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Mounting Panel mounting
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM), Parallel port
    Operating System Windows XP / Windows 2000
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 1000
    Application error in the runtime software (e.g. WinCC flexible Runtime crash). The operating system logs an application fault.
    Check the Windows Event Viewer for details. Reinstall or repair the runtime software. Ensure the software version is compatible with the Panel PC hardware.
    Event ID: 6008
    Unexpected system shutdown recorded by the operating system, indicating a previous unclean power loss or system crash.
    Check the 24 V DC power supply for stability and correct voltage level. Inspect wiring connections. Review system logs for underlying fault causes.
    BIOS POST Error
    The panel fails to complete the Power-On Self-Test during startup, indicating a hardware fault such as failed RAM or a corrupted BIOS.
    Reseat memory modules if accessible. Attempt a BIOS reset. If the fault persists, the mainboard or memory module may require replacement.
    No Boot Device Found
    The operating system cannot be loaded because the bootable storage device (CompactFlash card or hard disk) is not detected.
    Check that the CompactFlash card or hard disk is properly seated. Replace the storage medium and restore the OS image if the device has failed.
    Communication Timeout
    Loss of communication between the Panel PC runtime software and the connected PLC or controller, causing the HMI project to display a connection error.
    Verify Ethernet or serial cable connections. Check PLC IP address and communication parameters in the WinCC project configuration. Confirm the PLC is powered and running.
    Watchdog Timeout
    The system watchdog has triggered due to the operating system or application becoming unresponsive, causing an automatic system reset.
    Investigate running processes for high CPU load or software deadlocks. Update or reinstall the runtime application. Check for hardware faults causing system instability.
    Temperature Warning
    The internal temperature of the Panel PC has exceeded the recommended operating threshold, risking hardware damage or shutdown.
    Check that the panel enclosure ventilation is not obstructed. Verify ambient temperature is within the 0 to 45 °C operating range. Clean any dust from ventilation areas.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AA12-0CF0?

    The unit operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance to prevent system faults.

    What display size and resolution does this Panel PC have?

    The 6AV7612-0AA12-0CF0 is equipped with a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA).

    Which SCADA or HMI software is compatible with this Panel PC?

    The SIMATIC Panel PC 670 is compatible with Siemens WinCC and WinCC flexible runtime software, as well as other Windows-compatible SCADA packages. The specific software version must be compatible with the installed Windows operating system.

    What is the front panel protection rating of this unit?

    The front face of the 6AV7612-0AA12-0CF0 carries an IP65 protection rating, making it resistant to dust and low-pressure water jets.

    Can the storage medium (CompactFlash or hard disk) be replaced in the field?

    Yes, the storage medium can be replaced. After replacement, the operating system and HMI runtime software must be restored from a backup image or reinstalled from the appropriate installation media.

    Troubleshooting

    Panel display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector. Check internal fuses. Determine whether the system is booting (listen for HDD activity or check for backlight glow).

    Restore correct supply voltage if out of range. Replace any blown internal fuse. If the backlight is faulty, the display or inverter board requires replacement. If no boot activity is detected, investigate the storage medium and mainboard.

    Touchscreen input is not responding or is misaligned

    Check whether the touchscreen is physically damaged or contaminated. Determine if the touch controller driver is loaded correctly in the operating system.

    Clean the touchscreen surface. Perform a touchscreen recalibration using the Windows calibration utility or the Siemens panel configuration tool. If the touch controller is unresponsive, the touchscreen assembly may require replacement.

    Panel PC fails to boot and displays 'No Boot Device' or similar error

    Check whether the CompactFlash card or hard disk is properly seated in its connector. Attempt to detect the drive in the BIOS setup menu.

    Reseat the storage device. If the device is not detected in BIOS, replace the CompactFlash card or hard disk and restore the operating system and runtime software from a backup image.

    HMI runtime loses communication with the PLC intermittently

    Check Ethernet cable integrity and connector seating. Verify the PLC IP address and subnet configuration match the WinCC project settings. Monitor for network errors using Windows network diagnostics.

    Replace damaged Ethernet cables. Correct any IP address or subnet mismatches in the WinCC communication configuration. If using a managed switch, verify port settings and check for network congestion.

    System runs slowly or runtime software becomes unresponsive

    Check CPU and memory utilization in Windows Task Manager. Identify any background processes consuming excessive resources. Check available storage space on the boot drive.

    Terminate unnecessary background processes. Ensure the CompactFlash card or hard disk has sufficient free space. If the storage medium is nearly full or failing, replace it and restore a clean OS and runtime image.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart