Siemens 6AV7612-0AA10-0BF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA10-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC platform, offering a compact and robust solution for machine-level and process visualization.
The SIMATIC Panel PC 670 (6AV7612-0AA10-0BF0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology. It is powered by an Intel Celeron processor and runs on a Windows-based operating system, supporting SIMATIC WinCC flexible and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB, serial (COM), parallel, and Ethernet ports, enabling integration with a wide range of automation and peripheral devices. It is designed for panel mounting and operates from a 24 V DC supply.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, automotive, food and beverage, and process industries where a full PC-based HMI platform is required at the machine or control cabinet level. Its fanless or low-maintenance design options make it suitable for environments where reliability and reduced maintenance intervals are critical. The integration of standard PC architecture allows engineers to run custom visualization, data logging, and process control applications alongside standard SIMATIC software.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive Touch Screen |
| Input Voltage | 24 V DC |
| Processor | Intel Celeron |
| Operating System | Windows XP / Windows 2000 (factory configurable) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM), Parallel Port |
| Mounting | Panel Mounting |
| Protection Rating (Front) | IP65 |
| Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the Panel PC failed to complete the boot sequence correctly, often due to a corrupted OS or failed storage device.
Check the Compact Flash card or hard disk for errors. Reinstall or restore the operating system image if necessary. - Event ID: 1000
- Application crash — the HMI or SCADA application (e.g. WinCC flexible Runtime) has terminated unexpectedly.
Review Windows Event Viewer logs for the faulting module. Reinstall the HMI runtime software or update to the latest service pack. - Event ID: 7000
- Service failed to start — a required Windows service did not start during boot, which may prevent the HMI application from launching.
Check the Windows Services configuration. Ensure all required SIMATIC services are set to automatic startup and restart the panel. - BIOS POST Error
- Hardware initialization failure detected during Power-On Self-Test, indicating a memory, CPU, or hardware fault.
Reseat RAM modules if accessible. If the error persists, the mainboard or processor module may require replacement. - WinCC Flexible Runtime Error
- WinCC Flexible Runtime cannot establish a connection to the configured PLC or controller.
Verify Ethernet or MPI/PROFIBUS connection settings. Check IP address configuration and ensure the PLC is online and reachable. - Watchdog Timeout
- The system watchdog has triggered a reset because the operating system or application became unresponsive within the watchdog timeout period.
Investigate CPU load and running processes. Optimize the HMI project or increase the watchdog timeout interval in the BIOS/system settings. - Storage Device Error
- The Compact Flash card or hard disk is not detected or has reported read/write errors, preventing normal system operation.
Replace the Compact Flash card or hard disk with a compatible unit. Restore the system image from a backup.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AA10-0BF0?
The SIMATIC Panel PC 670 (6AV7612-0AA10-0BF0) operates from a 24 V DC power supply. Ensure the supply is stable and within the specified tolerance range.
What HMI software is compatible with this Panel PC?
This unit is compatible with Siemens SIMATIC WinCC flexible and WinCC, as well as other Windows-based SCADA and visualization software packages. The specific software version must be compatible with the installed operating system.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for panel-mount installation in industrial environments.
Can this Panel PC communicate with SIMATIC S7 PLCs?
Yes, the unit supports Ethernet-based communication with SIMATIC S7 PLCs using standard protocols such as S7 communication. Additional communication options may be available via expansion slots or external adapters.
What storage media does the 6AV7612-0AA10-0BF0 use?
The SIMATIC Panel PC 670 typically uses a Compact Flash card or an internal hard disk drive as the primary storage medium for the operating system and HMI application data.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify that the supply is within tolerance and that the power LED or status indicator responds. Inspect internal fuses if accessible.
Restore the correct 24 V DC supply. If the supply is correct and the display remains blank, the backlight inverter or the display panel itself may have failed and require replacement.
Touch screen does not respond or responds inaccurately
Determine whether the issue is a calibration problem or a hardware fault. Attempt to recalibrate the touch screen through the Windows control panel or SIMATIC configuration tool.
Recalibrate the resistive touch screen using the built-in calibration utility. If calibration does not resolve the issue, inspect the touch screen controller connection or replace the touch screen overlay.
Panel PC fails to boot and shows a BIOS or POST error
Observe the error message displayed during POST. Check whether the Compact Flash card or hard disk is detected in the BIOS. Reseat any accessible memory modules.
Replace the Compact Flash card with a pre-imaged replacement and restore the system image. If the fault persists after storage replacement, the mainboard may require repair or replacement.
HMI application loses communication with the PLC intermittently
Check the Ethernet cable and switch/hub connections. Verify the IP address settings on both the Panel PC and the PLC. Monitor the network for excessive traffic or collisions.
Replace faulty network cables or switch ports. Ensure IP addresses and subnet masks are correctly configured. Update the network adapter driver if an updated version is available for the installed OS.
System runs slowly or the HMI application freezes
Check CPU and memory utilization using Windows Task Manager. Identify any background processes consuming excessive resources. Check available storage space on the Compact Flash card or hard disk.
Terminate unnecessary background processes and disable non-essential startup programs. If storage is nearly full, archive or delete old log files. Consider upgrading the Compact Flash card to a higher-capacity unit if storage is a recurring issue.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page