The Siemens 6AV7612-0AA10-0BE0 is an industrial Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is a compact, panel-mounted industrial computing platform designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. The unit integrates a display, computing hardware, and industrial-grade I/O into a single front-panel-mounted enclosure.
The SIMATIC Panel PC 670 (6AV7612-0AA10-0BE0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an x86-compatible processor architecture and runs Microsoft Windows-based operating systems, enabling compatibility with standard SCADA and HMI software including WinCC and WinCC flexible. The unit provides standard PC interfaces including USB ports, serial COM ports, and Ethernet connectivity, and is designed for front-panel mounting with an IP65-rated front bezel for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. Its rugged industrial construction, fanless or low-maintenance cooling options, and compatibility with Siemens SIMATIC software make it suitable for continuous operation in factory floor environments where reliability and long-term availability of spare parts are critical requirements.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive Touch Screen |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Front panel mounting |
| Communication Interface | Ethernet (RJ45), USB, RS-232/RS-422/RS-485 |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Windows XP / Windows 2000 compatible |
Common Error Codes & System Events
- Event ID: 1000
- Application error in the HMI runtime software (e.g., WinCC flexible Runtime crash or unexpected termination).
Check Windows Event Viewer for detailed error logs. Reinstall or repair the HMI runtime software. Verify project file integrity. - Event ID: 7000
- Service failed to start during Windows boot sequence, which may prevent HMI runtime from launching correctly.
Check Windows Services configuration. Ensure all required SIMATIC services are set to automatic start. Reinstall software if services are corrupted. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or controller (e.g., S7-300/400 via Ethernet or MPI).
Verify network cable connections and IP address configuration. Check PLC communication settings and ensure the correct communication driver is installed and configured in the HMI project. - Watchdog Timeout
- Hardware or software watchdog has triggered due to system hang or excessive CPU load, causing an automatic restart.
Check for runaway processes using Windows Task Manager. Reduce CPU load by optimizing the HMI project. Verify that the watchdog timer settings are appropriate for the application. - Display Backlight Failure
- The LCD backlight has failed or dimmed significantly, resulting in a dark or unreadable display.
Replace the CCFL backlight lamp or the inverter board. If the unit is within service life, contact Siemens service or a qualified repair center for backlight replacement. - Storage Media Error
- Error reading from or writing to the internal CompactFlash card or hard disk, which may prevent the OS or HMI project from loading.
Check and reseat the CompactFlash card or hard disk. Replace the storage medium if faulty. Restore the OS and HMI project from a backup image. - Undervoltage Warning
- The 24 V DC supply voltage has dropped below the minimum operating threshold, causing unstable operation or shutdown.
Measure the supply voltage at the power connector. Ensure the power supply unit is rated for the Panel PC load. Check wiring for excessive voltage drop.
Frequently Asked Questions
What operating voltage does the 6AV7612-0AA10-0BE0 require?
The SIMATIC Panel PC 670 (6AV7612-0AA10-0BE0) operates on a 24 V DC supply voltage. Ensure the power supply is adequately rated for the unit's power consumption.
What HMI software is compatible with this Panel PC?
The unit is compatible with Siemens WinCC and WinCC flexible HMI software running on Windows. It supports standard SIMATIC communication drivers for connecting to S7-series PLCs.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AA10-0BE0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel installation.
What display size and resolution does this Panel PC have?
The unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen for operator input.
Can this Panel PC communicate with Siemens S7 PLCs?
Yes, the SIMATIC Panel PC 670 supports Ethernet-based communication with S7-300 and S7-400 PLCs using the appropriate SIMATIC NET communication drivers. Serial interfaces are also available for legacy connections.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power input connector. Verify the backlight inverter is functioning by listening for a faint high-frequency tone. Measure voltage at the inverter board input.
If supply voltage is correct but display is blank, replace the backlight inverter board or CCFL lamp. If no voltage is present, check the power supply unit and wiring. Inspect the internal fuse if accessible.
HMI runtime does not start after Windows boot
Check Windows Event Viewer for application or service errors. Verify that the SIMATIC runtime software and associated services are installed correctly and set to auto-start.
Reinstall the WinCC flexible Runtime or WinCC software. Restore the HMI project from backup. If the storage medium is corrupted, replace the CompactFlash card and restore the OS image.
Touch screen does not respond or is misaligned
Attempt to recalibrate the touch screen using the Windows touch screen calibration utility. Check for physical damage or contamination on the touch surface.
Run the touch screen calibration tool from the Windows Control Panel or SIMATIC configuration utility. Clean the touch surface with a soft cloth. If calibration fails repeatedly, the touch screen overlay may need replacement.
Loss of communication with PLC
Verify Ethernet cable connection and check the IP address configuration of both the Panel PC and the PLC. Use the Windows ping command to test network connectivity. Check the communication driver settings in the HMI project.
Correct any IP address conflicts or subnet mismatches. Replace the Ethernet cable if faulty. Reinstall the SIMATIC NET communication driver if the connection cannot be established after verifying network settings.
Unit restarts unexpectedly or freezes during operation
Check the 24 V DC supply for voltage dips or ripple using a multimeter or oscilloscope. Review Windows Event Viewer for critical errors or watchdog events. Monitor CPU and memory usage during operation.
Stabilize the power supply by using a dedicated, adequately rated 24 V DC source. Optimize the HMI project to reduce CPU load. If hardware faults are suspected, inspect the main board and memory modules for damage or loose connections.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page