Siemens 6AV7611-0AF32-0BF0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF32-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial automation environments. This unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside process control applications.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels and integrates a robust industrial-grade processor platform. It supports multiple communication interfaces including Ethernet (RJ45) and serial ports, and is compatible with standard PC expansion options. The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress in industrial settings. It operates on a 24 V DC supply and is built to withstand the vibration, temperature variation, and EMC requirements typical of factory floor environments.
The SIMATIC Panel PC 670 is widely deployed in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. Its PC-based architecture allows it to run Siemens WinCC, WinCC flexible, and third-party SCADA packages, making it suitable for complex visualization tasks requiring high processing capability. The front IP65 rating and industrial construction make it appropriate for installation directly on control panels and machine cabinets.
Technical Specifications
| Series | SIMATIC Panel PC 670 |
|---|---|
| Display Size | 12 inch |
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 65,536 colors |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mounting (front) |
| Certifications | CE, UL |
| Operating System | Windows XP Professional (embedded) |
Common Error Codes & System Events
- Event ID: 1000
- Application error — a running HMI or SCADA application has encountered an unhandled exception and terminated unexpectedly.
Check the Windows Event Viewer for detailed error logs. Reinstall or update the affected application. Verify that the application is compatible with the installed OS version. - Event ID: 7026
- A boot-start or system-start driver failed to load during Windows startup.
Boot into Safe Mode and check Device Manager for driver conflicts. Reinstall or update the relevant hardware driver. Check for corrupted system files using the Windows SFC utility. - Event ID: 6008
- Unexpected system shutdown — the previous system shutdown was unexpected, indicating a possible power loss or system crash.
Check the 24 V DC power supply for voltage stability. Inspect power connectors and cabling. Review the Windows Event Log for preceding error events that may have caused the crash. - Event ID: 41
- Kernel power error — the system rebooted without cleanly shutting down, typically caused by a power interruption or hardware fault.
Verify the stability of the 24 V DC supply voltage. Check for overheating by inspecting ventilation and ambient temperature. Test the internal power supply unit if the issue persists. - Event ID: 51
- Disk error — an error was detected on the device during a paging operation, indicating a potential hard disk or CompactFlash storage fault.
Run a disk check utility (chkdsk) on the storage device. Back up all data immediately. Replace the hard disk or CompactFlash card if errors persist. - Event ID: 1001
- Windows Error Reporting event — a system or application crash dump has been saved, indicating a prior fault condition.
Review the saved crash dump file using Windows Debugging Tools. Identify the faulting module and update or replace the associated driver or application. - Event ID: 2019
- Server service resource exhaustion — the system was unable to allocate pool memory, indicating a memory leak or insufficient RAM for running processes.
Restart the Panel PC to free memory. Reduce the number of concurrently running applications. Investigate running processes for memory leaks using Task Manager.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AF32-0BF0?
The SIMATIC Panel PC 670 6AV7611-0AF32-0BF0 operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7611-0AF32-0BF0 carries an IP65 protection rating, making it resistant to dust and low-pressure water jets. The rear of the unit is rated IP20.
Which HMI and SCADA software is compatible with this Panel PC?
The unit is compatible with Siemens WinCC, WinCC flexible, and other Windows-based SCADA and HMI applications. Third-party software compatible with the installed Windows operating system can also be used.
What communication interfaces are available on this unit?
The 6AV7611-0AF32-0BF0 provides Ethernet (RJ45), RS-232 serial, and USB interfaces for communication and peripheral connectivity. These allow integration with PLCs, network infrastructure, and external devices.
Can the storage medium on this Panel PC be replaced or upgraded?
The SIMATIC Panel PC 670 uses a replaceable hard disk or CompactFlash storage medium. Siemens recommends using approved storage devices and restoring the system image after replacement to ensure correct operation.
Troubleshooting
Display remains blank after power on
Check that the 24 V DC supply voltage is present and within tolerance at the power input connector. Verify that the power LED indicator is illuminated. Measure supply voltage under load to rule out supply instability.
Restore the supply voltage to the correct level. If the supply is correct but the display remains blank, inspect the internal display cable connections. Replace the backlight inverter or the display unit if the backlight has failed.
Panel PC fails to boot into Windows and shows a boot error
Attempt to boot from an external USB device to determine if the internal storage device has failed. Check the BIOS settings to confirm the correct boot device is selected. Listen for hard disk activity during startup.
Run a disk check utility on the internal storage. If the storage device is faulty, replace it with a compatible hard disk or CompactFlash card and restore the system image from a Siemens recovery backup.
Touchscreen does not respond to input
Verify that the touchscreen calibration has not been lost by checking the Windows control panel. Check for physical damage or contamination on the screen surface. Inspect the touchscreen controller connection internally.
Recalibrate the touchscreen using the Windows touchscreen calibration utility. Clean the screen surface with a soft, dry cloth. If calibration does not resolve the issue, replace the touchscreen overlay or the touchscreen controller board.
Ethernet communication is not established
Check the Ethernet cable and confirm the link LED on the RJ45 port is active. Verify the IP address configuration in Windows Network Settings. Test connectivity using the ping command from another device on the network.
Replace the Ethernet cable if faulty. Reconfigure the IP address settings to match the network requirements. Update the network adapter driver if the adapter is not recognized correctly in Device Manager.
Panel PC overheats and shuts down unexpectedly
Check the ambient temperature around the Panel PC installation. Inspect ventilation slots for dust blockage. Review the Windows Event Log for thermal-related shutdown events.
Clean all ventilation slots and ensure adequate airflow around the unit. Verify that the ambient operating temperature does not exceed 45 °C. If the unit continues to overheat, inspect the internal cooling fan (if fitted) and replace if it has failed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page