• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AF30-0AH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AF30-0AH0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AF30-0AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AF30-0AH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit integrates a display, computing hardware, and industrial I/O into a single compact panel-mount enclosure.

    The SIMATIC Panel PC 670 6AV7611-0AF30-0AH0 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA) and resistive touch screen technology. It is powered by an Intel Celeron processor and runs Microsoft Windows XP or Windows XP Embedded, supporting SIMATIC WinCC and other Siemens visualization software. The unit provides standard PC interfaces including USB, serial (RS-232), and Ethernet (RJ45), and supports expansion via PCI slots. It is built to withstand industrial environments with a front panel protection rating of IP65.

    The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical processing, and machine tool industries where a full PC-based HMI platform is required. Its ability to run standard Windows-based SCADA and visualization software makes it suitable for complex process visualization, data logging, and recipe management applications. The panel-mount form factor allows direct integration into control cabinets and operator panels on the factory floor.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Processor Intel Celeron
    Operating System Windows XP / Windows XP Embedded
    Front Protection Rating IP65
    Communication Interface Ethernet (RJ45), USB, RS-232 (serial)
    Expansion PCI slot(s)
    Mounting Panel mount
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Input Voltage 24 V DC
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup error or boot failure detected during POST.
    Check hard disk or Compact Flash card integrity. Verify BIOS settings and reseat memory modules. Replace storage media if corrupted.
    Event ID: 200
    Watchdog timeout — the application or operating system has stopped responding within the configured watchdog interval.
    Restart the Panel PC. Check the running application for software hangs. Reconfigure watchdog timeout interval if necessary.
    Event ID: 300
    Fan failure or thermal warning — internal cooling fan has stopped or CPU temperature has exceeded threshold.
    Inspect and clean the cooling fan. Replace the fan if defective. Ensure ambient temperature is within specification.
    Event ID: 400
    Battery low warning — the CMOS/RTC backup battery voltage is below the minimum threshold.
    Replace the internal CMOS backup battery (typically CR2032 or equivalent). Reset BIOS time and date after replacement.
    Event ID: 500
    Hard disk or storage media error — read/write failure on the internal hard disk or Compact Flash card.
    Run a disk diagnostic utility. Back up data immediately and replace the storage medium. Restore the operating system image.
    Event ID: 600
    Ethernet communication failure — loss of network connection or network adapter not detected.
    Check Ethernet cable and switch connection. Verify network adapter settings in Device Manager. Replace the network adapter if hardware fault is confirmed.
    Event ID: 700
    Display or graphics driver error — display output is incorrect or the graphics driver has failed to initialize.
    Reinstall or update the graphics driver. Check display cable connections internally. Replace the display unit if the fault persists.
    Event ID: 800
    USB device error — a connected USB device is not recognized or has caused a system fault.
    Disconnect all USB peripherals and reconnect one at a time to isolate the faulty device. Update USB drivers or replace the defective USB device.

    Frequently Asked Questions

    What display size and resolution does the 6AV7611-0AF30-0AH0 have?

    The unit features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA) and a resistive touchscreen interface.

    What operating system does the SIMATIC Panel PC 670 6AV7611-0AF30-0AH0 support?

    The Panel PC 670 supports Microsoft Windows XP and Windows XP Embedded, and is compatible with Siemens SIMATIC WinCC visualization software.

    What is the front panel protection rating of this Panel PC?

    The front panel of the 6AV7611-0AF30-0AH0 carries an IP65 protection rating, making it resistant to dust and water jets for industrial installation.

    What communication interfaces are available on this unit?

    The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces as standard, enabling connectivity to PLCs, networks, and peripheral devices.

    What is the supply voltage for the SIMATIC Panel PC 670?

    The Panel PC 670 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel-mounted devices.

    Troubleshooting

    Panel PC does not boot and display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify that the internal hard disk or Compact Flash card is properly seated and recognized in BIOS.

    Reseat the storage medium and memory modules. If the storage device is faulty, replace it and restore the operating system image from a backup or recovery medium.

    Touchscreen does not respond or registers incorrect touch positions

    Check if the touchscreen driver is correctly installed in the operating system. Verify that the touchscreen calibration has not been corrupted.

    Recalibrate the touchscreen using the Windows calibration utility. If the issue persists, reinstall the touchscreen driver or replace the touchscreen overlay.

    Panel PC overheats and shuts down unexpectedly

    Check the internal cooling fan for operation and inspect air vents for dust blockage. Verify that ambient temperature is within the 0 to 45 °C operating range.

    Clean the cooling fan and air vents with compressed air. Replace the cooling fan if it is not spinning. Ensure adequate ventilation around the panel enclosure.

    Ethernet communication is lost or the network is not detected

    Check the Ethernet cable connection and verify the network adapter status in Windows Device Manager. Test with a known-good cable and switch port.

    Replace the Ethernet cable if damaged. Update or reinstall the network adapter driver. If the hardware adapter is faulty, replace the internal network interface card.

    BIOS time and date reset after each power cycle

    The CMOS backup battery is likely depleted, causing loss of BIOS settings on power removal.

    Replace the internal CMOS backup battery with the correct type (typically CR2032). After replacement, re-enter BIOS settings including date, time, and boot order.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart