• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AF30-0AE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AF30-0AE0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AF30-0AE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AF30-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit combines a high-resolution display with a robust PC platform, providing both operator interface and computing functionality in a single integrated device.

    The SIMATIC Panel PC 670 6AV7611-0AF30-0AE0 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and a touch-sensitive screen for intuitive operator interaction. The unit is built around an industrial-grade processor platform and supports standard PC interfaces including USB, Ethernet (RJ45), and serial COM ports. It is designed to run Windows-based operating systems and is compatible with Siemens WinCC and other SCADA/HMI software packages. The front panel carries an IP65 protection rating, making it resistant to dust and water ingress from the front.

    The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine tool industries where a combination of visualization and local computing power is required. It is suitable for use as a central operator station in production lines, as a local HMI on complex machinery, and in applications requiring integration with Siemens SIMATIC S7 PLC systems. Its rugged construction and industrial-grade components make it appropriate for continuous operation in factory floor environments.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Power Consumption Approx. 80 W
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Communication Interface Ethernet RJ45, USB, COM (RS-232)
    Mounting Panel mounting
    Series SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence.
    Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration. Replace storage media if faulty.
    Event ID: 200
    Watchdog timeout triggered, indicating the application software has stopped responding.
    Restart the application software. Check for software conflicts or memory issues. Update or reinstall the HMI runtime software if the problem persists.
    Event ID: 300
    Fan failure or thermal warning detected; internal temperature exceeding threshold.
    Check and clean the cooling fan and ventilation slots. Ensure ambient temperature is within specification. Replace the fan unit if it has failed.
    Event ID: 400
    Ethernet communication link failure; no network connection detected.
    Check Ethernet cable and switch/hub connection. Verify IP address configuration. Inspect the RJ45 port for physical damage.
    Event ID: 500
    Touchscreen calibration error or touch input not responding correctly.
    Recalibrate the touchscreen via the operating system control panel. Check touchscreen controller driver installation. Replace touchscreen overlay if hardware fault is confirmed.
    Event ID: 600
    Battery low warning for the real-time clock (RTC) backup battery.
    Replace the internal CMOS/RTC backup battery with the correct type. Refer to the device documentation for battery location and replacement procedure.
    Event ID: 700
    Storage media error; read/write failure on hard disk or CompactFlash card.
    Run a disk check utility to identify bad sectors. Back up data immediately and replace the storage medium. Restore the OS and application software from backup.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7611-0AF30-0AE0?

    The unit operates on 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC 670 devices.

    What operating system does the SIMATIC Panel PC 670 support?

    The Panel PC 670 is designed to run Windows XP Embedded or Windows XP Professional. It is compatible with Siemens WinCC and other Windows-based HMI and SCADA software.

    Is the 6AV7611-0AF30-0AE0 compatible with Siemens S7 PLCs?

    Yes, the Panel PC 670 can communicate with Siemens SIMATIC S7-300 and S7-400 PLCs via Ethernet (TCP/IP) or PROFIBUS using appropriate communication cards and WinCC software.

    What is the front panel protection rating of this Panel PC?

    The front panel of the 6AV7611-0AF30-0AE0 carries an IP65 protection rating, providing full dust protection and resistance to water jets.

    Can the storage medium on this Panel PC be replaced or upgraded?

    Yes, the Panel PC 670 uses a replaceable hard disk or CompactFlash card for storage. Replacement or upgrade is possible, but the operating system and application software must be reinstalled or restored from a backup image.

    Troubleshooting

    Display remains blank after power is applied

    Check that 24 V DC supply is present at the power connector. Verify the power LED status. Measure supply voltage at the input terminals to rule out power supply issues.

    Ensure the 24 V DC supply is within tolerance. Replace the internal power supply board if no output voltage is detected. If the backlight is faulty, replace the inverter board or the display unit.

    Touchscreen does not respond or registers incorrect touch positions

    Attempt to recalibrate the touchscreen through the Windows control panel. Check if the touchscreen controller is recognized in Device Manager.

    Recalibrate the touchscreen using the calibration utility. If the problem persists, reinstall the touchscreen driver. Replace the touchscreen overlay or the touch controller board if hardware damage is confirmed.

    Panel PC fails to boot or continuously restarts

    Check the storage medium (hard disk or CompactFlash) for errors using a disk diagnostic tool. Inspect the BIOS POST messages for specific error indications.

    Run a disk check and repair utility. If the storage medium is corrupted or failed, replace it and restore the operating system and application software from a backup image.

    Ethernet communication not working

    Verify the Ethernet cable connection and check the link LED on the RJ45 port. Confirm the IP address configuration in Windows network settings.

    Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network. Update or reinstall the network adapter driver if the interface is not recognized by the OS.

    System clock loses time after power off

    The real-time clock (RTC) backup battery may be discharged. Check the BIOS for a low battery warning or incorrect date/time after power cycling.

    Replace the internal CMOS backup battery with the correct replacement type. After replacement, reset the date and time in the BIOS and verify correct timekeeping.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart