Siemens 6AV7611-0AF22-0AJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF22-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling both operator control and data processing within a single ruggedized enclosure.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch-sensitive screen for intuitive operator interaction. It is powered by an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens visualization software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces, and is designed for front-panel mounting with an IP65-rated front bezel for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI solution is required. Its rugged construction and industrial-grade components make it suitable for installation in control cabinets and operator panels in industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. The combination of standard PC interfaces and Siemens automation software compatibility makes it a practical choice for complex visualization and SCADA applications.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 |
| Mounting | Panel mounting (front flush) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Microsoft Windows XP/2000 |
Common Error Codes & System Events
- Event ID: 1000
- Application error — a software application has encountered a fatal error and terminated unexpectedly.
Check Windows Event Viewer for details. Reinstall or update the affected application. Verify software compatibility with the installed OS version. - Event ID: 7026
- A boot-start or system-start driver failed to load during Windows startup.
Check Device Manager for driver conflicts. Reinstall the appropriate driver or restore the system from a known-good backup. - Event ID: 6008
- The system was shut down unexpectedly, indicating a previous unclean shutdown or power loss.
Check the 24 V DC power supply for stability. Inspect power connectors and ensure UPS or stable supply is in place. - BIOS POST Error
- Hardware fault detected during Power-On Self-Test, preventing normal boot.
Check RAM seating, CompactFlash or hard disk connection, and CPU module. Replace faulty hardware component as identified by POST beep codes or on-screen message. - WinCC Runtime Error
- SIMATIC WinCC runtime has failed to start or has crashed, leaving the HMI without visualization.
Verify WinCC license dongle is present and valid. Reinstall WinCC runtime and check project configuration for errors. - Network Connection Lost
- Ethernet communication to the PLC or SCADA server has been interrupted.
Check Ethernet cable and switch connections. Verify IP address configuration in Windows Network Settings and confirm PLC communication settings match. - Touchscreen Not Responding
- The resistive touchscreen is not registering input or is registering incorrect touch positions.
Recalibrate the touchscreen using the Siemens touchscreen calibration utility in the Control Panel. If calibration fails, inspect the touchscreen controller connection or replace the touchscreen assembly.
Frequently Asked Questions
What display size and resolution does the 6AV7611-0AF22-0AJ0 have?
This unit features a 12-inch TFT color LCD with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen interface.
What is the supply voltage for this Panel PC?
The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
Is this Panel PC compatible with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens SIMATIC WinCC visualization software, as well as other SIMATIC HMI software packages designed for Windows-based panel PCs.
What is the front panel protection rating of this unit?
The front bezel of the 6AV7611-0AF22-0AJ0 carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for industrial panel installation.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces, enabling connectivity to PLCs, SCADA systems, and peripheral devices.
Troubleshooting
Panel PC does not power on after switching on the 24 V DC supply
Measure the 24 V DC supply voltage at the power input connector. Check for blown internal fuses and verify the power supply unit output.
Ensure the supply voltage is within the specified 24 V DC range. Replace any blown fuses and verify wiring polarity. If the internal power supply module is faulty, replace it with a compatible spare.
Display is blank but the PC appears to be running (fans audible, LEDs active)
Check the display backlight by shining a torch at the screen to see if a faint image is visible. Verify the display cable connection between the mainboard and the LCD panel.
If the backlight is failed, replace the CCFL backlight or the entire LCD assembly. If the display cable is loose or damaged, reseat or replace it.
Touchscreen input is inaccurate or unresponsive
Attempt touchscreen recalibration via the Windows Control Panel calibration utility. Check for physical damage or contamination on the touchscreen surface.
Recalibrate the touchscreen using the Siemens calibration tool. Clean the screen surface with a soft cloth. If the problem persists, replace the touchscreen controller board or the touchscreen overlay.
System boots to BIOS or fails to load Windows
Check the CompactFlash card or hard disk drive for errors using BIOS diagnostics. Listen for POST beep codes that indicate specific hardware faults.
Reseat the CompactFlash card or hard disk. If the storage medium is corrupted, restore the Windows image from a Siemens recovery medium or a previously created system backup.
Loss of communication with PLC over Ethernet
Verify the Ethernet cable connection and check the link LED on the RJ45 port. Confirm IP address settings in Windows Network Connections and compare with PLC configuration.
Replace the Ethernet cable if damaged. Reconfigure the IP address to match the required network subnet. Check firewall settings in Windows and ensure the correct communication driver is installed and running.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page