
Siemens 6AV7611-0AF22-0AH0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF22-0AH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and rugged solution for process visualization and control.
The SIMATIC Panel PC 670 6AV7611-0AF22-0AH0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard PC interfaces including USB, serial (COM), and Ethernet ports, enabling integration with a wide range of automation and control systems. It is designed for front-panel mounting with an IP65-rated front face, protecting against dust and water ingress in industrial settings.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a robust, integrated PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. Its compatibility with Siemens SIMATIC software and standard PC architecture makes it a practical choice for visualization, data acquisition, and supervisory control tasks.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP Protection (Front) | IP65 |
| IP Protection (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting (front) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the Panel PC failed to complete the boot sequence correctly.
Check power supply voltage at 24 V DC input. Verify that the operating system and BIOS settings are intact. Reload or restore the OS image if corrupted. - Event ID: 200
- Touchscreen calibration error — the touch input is not responding or is misaligned.
Recalibrate the touchscreen via the Windows control panel or SIMATIC HMI configuration tool. If the issue persists, check the touch controller connection internally. - Event ID: 300
- Communication interface fault — loss of communication on the Ethernet or serial interface.
Check cable connections and network settings. Verify IP address configuration and ensure the correct communication driver is installed in WinCC or the HMI application. - Event ID: 400
- Runtime software error — SIMATIC WinCC Runtime or HMI application has stopped unexpectedly.
Restart the runtime application. Check the Windows event log for application errors. Reinstall the runtime software if the error recurs. - Event ID: 500
- Hardware watchdog timeout — the system watchdog has triggered due to a software hang or system overload.
Investigate CPU load and running processes. Reduce system load or optimize the HMI application. Update firmware or BIOS if a known watchdog issue exists. - Event ID: 600
- Storage media error — fault detected on the hard disk or CompactFlash storage device.
Run a disk check utility (chkdsk) on the storage device. Back up data immediately and replace the storage medium if errors are found. - Event ID: 700
- Fan or thermal warning — internal temperature has exceeded the recommended operating threshold.
Check that ambient temperature is within the 0–45 °C operating range. Clean any dust from ventilation openings. Verify that the cooling fan is operational and replace if faulty.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AF22-0AH0?
The unit operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.
What operating system does the SIMATIC Panel PC 670 support?
The Panel PC 670 supports Microsoft Windows operating systems, typically Windows XP Professional or Windows 2000, depending on the specific configuration ordered. It is compatible with SIMATIC WinCC and other Siemens HMI software.
Is the 6AV7611-0AF22-0AH0 compatible with SIMATIC WinCC?
Yes, this Panel PC is designed to run SIMATIC WinCC and other Siemens visualization software packages natively, as it is based on a standard PC architecture with Siemens-qualified hardware.
What is the IP protection rating of this Panel PC?
The front face of the unit is rated IP65, providing protection against dust and water jets. The rear of the unit is rated IP20.
Can the storage medium be replaced or upgraded in the field?
Yes, the SIMATIC Panel PC 670 supports replacement of the hard disk or CompactFlash card. Siemens provides restore CDs or image files to reload the operating system and software after a storage medium replacement.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power input connector. Verify that the power LED indicator is illuminated. Measure voltage at the internal power supply output rails.
Restore the correct 24 V DC supply. If the supply is correct but the display remains blank, the internal power supply board or the backlight inverter may be faulty and should be replaced.
Touchscreen does not respond or registers incorrect input positions
Attempt to recalibrate the touchscreen through the Windows control panel. Check whether the touch controller is recognized in Device Manager.
Perform a full touchscreen recalibration. If the issue persists, inspect the internal ribbon cable connecting the touch panel to the controller board and reseat or replace it as necessary.
Unit fails to boot into Windows and displays a BIOS or boot error
Check the storage medium (hard disk or CompactFlash) for errors using a disk check utility. Verify BIOS settings are correct and the boot device is properly selected.
Restore the operating system image using the Siemens-supplied restore CD or image file. Replace the storage medium if it is physically faulty.
Loss of communication with PLC or SCADA system
Verify Ethernet cable connection and check the IP address configuration in Windows network settings. Confirm that the correct communication driver is installed and active in the HMI application.
Reconfigure the network settings to match the plant network. Reinstall or update the communication driver. Replace the Ethernet cable or switch port if a hardware fault is suspected.
System overheats and shuts down or becomes unstable
Check the ambient temperature around the panel installation. Inspect the ventilation openings for dust blockage. Verify that the internal cooling fan is spinning.
Ensure the installation environment is within the 0–45 °C operating range. Clean dust from all ventilation openings. Replace the internal cooling fan if it is not functioning correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page



